The current status of CZT SPECT myocardial blood flow and reserve assessment: Tips and tricks

被引:35
作者
Zavadovsky, Konstantin V. [1 ,2 ]
Mochula, Andrew V. [1 ]
Maltseva, Alina N. [1 ]
Shipulin, Vladimir V. [1 ]
Sazonova, Svetlana I. [1 ]
Gulya, Marina O. [1 ]
Liga, Ricardo [3 ]
Gimelli, Alessia [4 ]
机构
[1] Russian Acad Sci, Tomsk Natl Res Med Ctr, Cardiol Res Inst, Kievskaya Str 111A, Tomsk 634012, Russia
[2] Siberian State Med Univ, Tomsk, Russia
[3] Univ Pisa, Pisa, Italy
[4] CNR Gabriele Monasterio, Fdn Toscana, Pisa, Italy
关键词
SPECT; CZT; CAD; Myocardial ischemia; Myocardial blood flow; Myocardial flow reserve;
D O I
10.1007/s12350-021-02620-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cardiac PET-derived measurements of myocardial blood flow (MBF) and myocardial flow reserve (MFR) are proven robust indexes of the severity of coronary artery disease (CAD). They facilitate the diagnosis of diffuse epicardial and microvascular disease and are also of prognostic significance. However, low availability and high cost have limited their wide clinical implementation. Over the last 15 years, cadmium zinc telluride (CZT)-based detectors have been implemented into SPECT imaging devices. Myocardial perfusion scintigraphy can be performed faster and with less radiation exposure as compared with standard gamma cameras. Rapid dynamic SPECT studies with higher count rates can be performed. This technological breakthrough has renewed the interest in SPECT MBF assessment in patients with CAD. Currently, two cardiac-centered CZT gamma cameras are available commercially-Discovery NM530c and D-SPECT. They differ in parameters such as collimator design, number of detectors, sensitivity, spatial resolution and image reconstruction. A number of publications have focused on the feasibility of dynamic CZT SPECT and on the correlation with cardiac PET and invasive coronary angiography measurements of fractional flow reserve. Current study reviews the present status of MBF and MFR assessment with CZT SPECT. It also aims to provide an overview of specific issues related to acquisition, processing and interpretation of quantitative studies in patients with CAD.
引用
收藏
页码:3137 / 3151
页数:15
相关论文
共 72 条
[1]   First validation of myocardial flow reserve assessed by dynamic 99mTc-sestamibi CZT-SPECT camera: head to head comparison with 15O-water PET and fractional flow reserve in patients with suspected coronary artery disease. The WATERDAY study [J].
Agostini, Denis ;
Roule, Vincent ;
Nganoa, Catherine ;
Roth, Nathaniel ;
Baavour, Raphael ;
Parienti, Jean-Jacques ;
Beygui, Farzin ;
Manrique, Alain .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 (07) :1079-1090
[2]   Coronary atherosclerotic burden vs. coronary vascular function in diabetic and nondiabetic patients with normal myocardial perfusion: a propensity score analysis [J].
Assante, Roberta ;
Acampa, Wanda ;
Zampella, Emilia ;
Arumugam, Parthiban ;
Nappi, Carmela ;
Gaudieri, Valeria ;
Panico, Mariarosaria ;
Magliulo, Mario ;
Tonge, Christine M. ;
Petretta, Mario ;
Cuocolo, Alberto .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 (07) :1129-1135
[3]   Impact of attenuation correction for CZT-SPECT measurement of myocardial blood flow [J].
Bailly, Matthieu ;
Thibault, Frederique ;
Courtehoux, Maxime ;
Metrard, Gilles ;
Ribeiro, Maria Joao .
JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (06) :2560-2568
[4]   Underestimation of coronary artery disease with SPECT perfusion imaging [J].
Beller, George A. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2008, 15 (02) :151-153
[5]   SPECT Myocardial Perfusion Reserve in Patients with Multivessel Coronary Disease: Correlation with Angiographic Findings and Invasive Fractional Flow Reserve Measurements [J].
Ben Bouallegue, Faycal ;
Roubille, Francois ;
Lattuca, Benoit ;
Cung, Thien Tri ;
Macia, Jean-Christophe ;
Gervasoni, Richard ;
Leclercq, Florence ;
Mariano-Goulart, Denis .
JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (11) :1712-1717
[6]   Quantification of Myocardial Perfusion Reserve Using Dynamic SPECT Imaging in Humans: A Feasibility Study [J].
Ben-Haim, Simona ;
Murthy, Venkatesh L. ;
Breault, Christopher ;
Allie, Rayjanah ;
Sitek, Arkadiusz ;
Roth, Nathaniel ;
Fantony, Jolene ;
Moore, Stephen C. ;
Park, Mi-Ae ;
Kijewski, Marie ;
Haroon, Athar ;
Slomka, Piotr ;
Erlandsson, Kjell ;
Baavour, Rafael ;
Zilberstien, Yoel ;
Bomanji, Jamshed ;
Di Carli, Marcelo F. .
JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (06) :873-879
[7]   Underestimation of extent of ischemia by gated SPECT myocardial perfusion imaging in patients with left main coronary artery disease [J].
Berman, Daniel S. ;
Kang, Xingping ;
Slomka, Piotr J. ;
Gerlach, James ;
de Yang, Ling ;
Hayes, Sean W. ;
Friedman, John D. ;
Thomson, Louise E. J. ;
Germano, Guido .
JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (04) :521-528
[8]   A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential [J].
Bocher, Moshe ;
Blevis, Ira M. ;
Tsukerman, Leonid ;
Shrem, Yigal ;
Kovalski, Gil ;
Volokh, Lana .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (10) :1887-1902
[9]  
Bom MJ., 2019, EUR HEART J CARDIOVA
[10]   The Clinical Value of Myocardial Blood Flow Measurement [J].
Camici, Paolo G. ;
Rimoldi, Ornella E. .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (07) :1076-1087