Detector design issues for compact nuclear emission cameras dedicated to breast imaging

被引:25
作者
Levin, CS
机构
[1] San Diego VA Med Ctr, Div Nucl Med, San Diego, CA 92161 USA
[2] UCSD, Sch Med, Dept Radiol, San Diego, CA 92161 USA
关键词
breast imaging; nuclear medicine; position-sensitive detectors; detectors; functional imaging;
D O I
10.1016/S0168-9002(02)01893-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Certain gamma ray and positron emitting radiotracers have shown great promise for use in the detection, diagnosis and staging of breast cancer. Unfortunately, standard nuclear emission cameras (SPECT, PET) found in the clinic are not practical for breast imaging of these emissions due to inadequate spatial and energy resolutions and sensitivity, large and awkward size, and relatively high cost per study. High spatial and energy resolutions and sensitivity are needed for good lesion detectability. Due to these limitations of standard cameras, there has been recent research into the development of small, compact nuclear emission imagers dedicated for close-proximity breast imaging. The small detector head size means a variety of exotic detectors or collimators may be implemented to improve spatial and energy resolution and sensitivity performances at a reasonable cost. In this paper, we will present some of the compact gamma ray and annihilation photon imaging detector designs that have been proposed and/or developed for dedicated breast imaging. We will review the physics and discuss the advantages and disadvantages of various detector configurations. Finally we will estimate the fundamental spatial resolution potential available with close-proximity nuclear emission imaging and discuss how one may approach those limits through proper detector design. Published by Elsevier Science B.V.
引用
收藏
页码:60 / 74
页数:15
相关论文
共 20 条
[1]   Signals induced in semiconductor gamma-ray imaging detectors [J].
Eskin, JD ;
Barrett, HH ;
Barber, HB .
JOURNAL OF APPLIED PHYSICS, 1999, 85 (02) :647-659
[2]   Position and energy resolution of a new gamma-ray detector based on a single CsI(Tl) scintillator coupled to a silicon drift chamber array [J].
Fiorini, C ;
Perotti, F ;
Labanti, C ;
Longoni, A ;
Rossi, E .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (04) :858-864
[3]   Monte Carlo simulation of breast tumor imaging properties with compact, discrete gamma cameras [J].
Gruber, GJ ;
Moses, WW ;
Derenzo, SE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (06) :2119-2123
[4]   A 3D HIDAC-PET camera with sub-millimetre resolution for imaging small animals [J].
Jeavons, AP ;
Chandler, RA ;
Dettmar, CAR .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) :468-473
[5]   POSITION-SENSITIVE PHOTOMULTIPLIER TUBES FOR SCINTILLATION IMAGING [J].
KUME, H ;
MURAMATSU, S ;
IIDA, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) :359-363
[6]   Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution [J].
Levin, CS ;
Hoffman, EJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (03) :781-799
[7]  
LEVIN CS, 1997 IEEE MED IM C A
[8]  
LEVIN CS, 1997, IEEE T NUCL SCI, V44, P15130
[9]  
MACDONALD LR, 2000, 2000 SPIE MED APPL P
[10]   Development of an application specific scintimammography detector based on a crystal scintillator array and a PSPMT [J].
Majewski, S ;
Farzanpay, F ;
Goode, A ;
Kross, B ;
Steinbach, D ;
Weisenberger, A ;
Williams, M ;
Wojcik, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 409 (1-3) :520-523