摘要
Microdialysis coupled with optical absorbance or fluorescence measurement has been used to monitor pH, pCO(2), and pO(2) in blood and buffer solutions. The system employs micro-flow streams of reagents, a simple optical system and a method of achieving steady microliter per minute flow rates. When integrated in a recirculating flow loop, the sensor has an excellent resolution in the physiologic range in buffer of +/-0.003 pH units, +/-0.5 mm Hg pCO(2), and +/-1.5 mm Hg pO(2) with response times in heparinized bovine blood of 4.8 min, 1.8 min, and 2.1 min for pH, pCO(2), and pO(2), respectively. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:183 / 188
页数:6
相关论文
共 22 条
  • [1] MEASUREMENT OF SODIUM-HYDROXIDE CONCENTRATION WITH A RENEWABLE REAGENT-BASED FIBEROPTIC SENSOR
    BERMAN, RJ
    CHRISTIAN, GD
    BURGESS, LW
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (19) : 2066 - 2071
  • [2] BOLINDER J, 1992, MICRODIALYSIS MEASUR
  • [3] BROWN ML, 1998, THESIS ARIZONA STATE
  • [4] Intravascular carbon dioxide monitoring using micro-flow colorimetry
    Cooney, CG
    Towe, BC
    [J]. BIOSENSORS & BIOELECTRONICS, 1997, 12 (01) : 11 - 17
  • [5] MEASUREMENT OF SEAWATER PCO2 USING A RENEWABLE-REAGENT FIBER OPTIC SENSOR WITH COLORIMETRIC DETECTION
    DEGRANDPRE, MD
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (04) : 331 - 337
  • [6] Evaluation of an on-demand, ex vivo bedside blood gas monitor on pulmonary artery blood gas determinations
    Franklin, ML
    Peruzzi, WT
    Moen, SG
    Shapiro, BA
    [J]. ANESTHESIA AND ANALGESIA, 1996, 83 (03) : 500 - 504
  • [7] OPTICAL FLUORESCENCE AND ITS APPLICATION TO AN INTRAVASCULAR BLOOD-GAS MONITORING-SYSTEM
    GEHRICH, JL
    LUBBERS, DW
    OPITZ, N
    HANSMANN, DR
    MILLER, WW
    TUSA, JK
    YAFUSO, M
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (02) : 117 - 132
  • [8] DEVELOPMENT OF A MINIATURIZED GLUCOSE MONITORING-SYSTEM BY COMBINING A NEEDLE-TYPE GLUCOSE SENSOR WITH MICRODIALYSIS SAMPLING METHOD - LONG-TERM SUBCUTANEOUS TISSUE GLUCOSE MONITORING IN AMBULATORY DIABETIC-PATIENTS
    HASHIGUCHI, Y
    UEMURA, T
    SAKAKIDA, M
    KAJIWARA, K
    NISHIDA, K
    SHICHIRI, M
    [J]. DIABETES CARE, 1994, 17 (05) : 387 - 396
  • [9] CHARACTERIZATION BY MICRODIALYSIS OF INTERCELLULAR GLUCOSE LEVEL IN SUBCUTANEOUS TISSUE IN HUMANS
    JANSSON, PA
    FOWELIN, J
    SMITH, U
    LONNROTH, P
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1988, 255 (02): : E218 - E220
  • [10] DUAL-ANALYTE FIBEROPTIC SENSOR FOR THE SIMULTANEOUS AND CONTINUOUS MEASUREMENT OF GLUCOSE AND OXYGEN
    LI, L
    WALT, DR
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (20) : 3746 - 3752