Fault-Tolerant Control of Cascaded H-Bridge Converters Using Double Zero-Sequence Voltage Injection and DC Voltage Optimization

被引:7
作者
Ji, Zhendong [1 ]
Zhao, Jianfeng [1 ]
Sun, Yichao [1 ]
Yao, Xiaojun [1 ]
Zhu, Zean [1 ]
机构
[1] Southeast Univ, Sch Elect Engn, Nanjing, Jiangsu, Peoples R China
关键词
Cascaded H-bridge converter; DC voltage balancing; DC voltage optimization; Fault-tolerant control; Star connection; Zero-sequence voltage; CONTROL STRATEGY; BALANCE CONTROL; MULTILEVEL; OPERATION; MODULATION; INVERTER; DESIGN;
D O I
10.6113/JPE.2014.14.5.946
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Cascaded H-Bridge (CHB) converters can be directly connected to medium-voltage grids without using transformers and they possess the advantages of large capacity and low harmonics. They are significant tools for providing grid connections in large-capacity renewable energy systems. However, the reliability of a grid-connected CHB converter can be seriously influenced by the number of power switching devices that exist in the structure. This paper proposes a fault-tolerant control strategy based on double zero-sequence voltage injection and DC voltage optimization to improve the reliability of star-connected CHB converters after one or more power units have been bypassed. By injecting double zero-sequence voltages into each phase cluster, the DC voltages of the healthy units can be rapidly balanced after the faulty units are bypassed. In addition, optimizing the DC voltage increases the number of faulty units that can be tolerated and improves the reliability of the converter. Simulations and experimental results are shown for a seven-level three-phase CHB converter to validate the efficiency and feasibility of this strategy.
引用
收藏
页码:946 / 956
页数:11
相关论文
共 19 条
  • [1] Control and performance of a transformerless cascade PWM STATCOM with star configuration
    Akagi, Hirofumi
    Inoue, Shigenori
    Yoshii, Tsurugi
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2007, 43 (04) : 1041 - 1049
  • [2] Modified space vector modulation for fault-tolerant operation of multilevel cascaded H-bridge inverters
    Aleenejad, Mohsen
    Iman-Eini, Hossein
    Farhangi, Shahrokh
    [J]. IET POWER ELECTRONICS, 2013, 6 (04) : 742 - 751
  • [3] [Anonymous], 2009, PROC 13 EUR C POWER
  • [4] Energy-Balance Control of PV Cascaded Multilevel Grid-Connected Inverters Under Level-Shifted and Phase-Shifted PWMs
    Chavarria, Javier
    Biel, Domingo
    Guinjoan, Francesc
    Meza, Carlos
    Negroni, Juan J.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (01) : 98 - 111
  • [5] Modulation strategies for fault-tolerant operation of H-bridge multilevel inverters
    Correa, Pablo
    Pacas, Mario
    Rodriguez, Jose
    [J]. 2006 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1-7, 2006, : 1589 - +
  • [6] Enhancing the reliability of modular medium-voltage drives
    Hammond, PW
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2002, 49 (05) : 948 - 954
  • [7] A Fault-Tolerant Control Strategy for Cascaded H-Bridge Multilevel Rectifiers
    Iman-Eini, Hossein
    Farhangi, Shahrokh
    Schanen, Jean-Luc
    Khakbazan-Fard, Mahboubeh
    [J]. JOURNAL OF POWER ELECTRONICS, 2010, 10 (01) : 34 - 42
  • [8] Extended Operation of Cascade Multicell Converters Under Fault Condition
    Lezana, Pablo
    Ortiz, Gabriel
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (07) : 2697 - 2703
  • [9] Reconfiguration of carrier-based modulation strategy for fault tolerant multilevel inverters
    Ma, Mingyao
    Hu, Lei
    Chen, Alian
    He, Xiangning
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2007, 22 (05) : 2050 - 2060
  • [10] Active-Power Control of Individual Converter Cells for a Battery Energy Storage System Based on a Multilevel Cascade PWM Converter
    Maharjan, Laxman
    Yamagishi, Tsukasa
    Akagi, Hirofumi
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (03) : 1099 - 1107