A data-driven approach towards fast economic dispatch in electricity-gas coupled systems based on artificial neural network

被引:29
作者
Liu, Haizhou [1 ]
Shen, Xinwei [1 ]
Guo, Qinglai [1 ,2 ]
Sun, Hongbin [1 ,2 ]
机构
[1] Tsinghua Univ, Tsinghua Berkeley Shenzhen Inst, Tsinghua Shenzhen Int Grad Sch, Shenzhen 518057, Peoples R China
[2] Tsinghua Univ, Dept Elect Engn, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Electricity-gas coupled system; Artificial neural network; Data-driven; Economic dispatch; Piecewise linearization; NATURAL-GAS; INTEGRATED POWER;
D O I
10.1016/j.apenergy.2021.116480
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The optimization of electricity-gas coupled systems is typically complicated by the nonconvex relationships such as gas flow equations. Piecewise linearization, despite being one of the few solutions that guarantee exactness and optimality, is often discarded for an exceptionally long computational time. In this paper, we present a novel data-driven approach based on artificial neural networks, to enable fast economic dispatch in electricity-gas coupled systems, by utilizing simulation data from the piecewise-linearization-based model-driven method. Load profiles at each electric bus and gas node are fed into the artificial neural network as input neurons; optimal economic dispatch results are set as output neurons, where the dispatch results can be either continuous (e.g. power and gas output) or binary (e.g. scenario feasibility). In generating power and gas outputs, the slack generator method is proposed to further eliminate load mismatch. Case studies on an integrated Belgium 20-node gas/IEEE 24-bus power system show that, after the artificial neural network is properly trained, the data-driven economic dispatch method is 10(4) similar to 10(5) times faster than model-driven piecewise linearization. It even outperforms second-order cone programming, a well-known convex relaxation technique to model natural gas systems, in terms of both the coupled system's state recovery accuracy and computational efficiency. Furthermore, the data-driven method is applied to a multi-period dispatch problem to demonstrate its scalability.
引用
收藏
页数:8
相关论文
共 29 条
  • [1] Abadi M, 2016, PROCEEDINGS OF OSDI'16: 12TH USENIX SYMPOSIUM ON OPERATING SYSTEMS DESIGN AND IMPLEMENTATION, P265
  • [2] Andrew NG, 2020, MACHINE LEARNING YEA
  • [3] Association GPS, 1982, ENG DATA BOOK
  • [4] Ba J., 2013, ADV NEURAL INFORM PR, P3084
  • [5] One-segment linearization modeling of electricity-gas system optimization
    Bao, Shiyuan
    Yang, Zhifang
    Guo, Lin
    Yu, Juan
    Dai, Wei
    [J]. ENERGY, 2020, 197
  • [6] Day-ahead building-level load forecasts using deep learning vs. traditional time-series techniques
    Cai, Mengmeng
    Pipattanasomporn, Manisa
    Rahman, Saifur
    [J]. APPLIED ENERGY, 2019, 236 : 1078 - 1088
  • [7] Unit Commitment With an Enhanced Natural Gas-Flow Model
    Chen, Sheng
    Conejo, Antonio J.
    Sioshansi, Ramteen
    Wei, Zhinong
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2019, 34 (05) : 3729 - 3738
  • [8] Stochastic look-ahead dispatch for coupled electricity and natural-gas networks
    Chen, Sheng
    Wei, Zhinong
    Sun, Guoqiang
    Wang, Dan
    Zhang, Yong
    Ma, Zhoujun
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2018, 164 : 159 - 166
  • [9] Integrated Power and Natural Gas Model for Energy Adequacy in Short-Term Operation
    Correa-Posada, Carlos M.
    Sanchez-Martin, Pedro
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2015, 30 (06) : 3347 - 3355
  • [10] Ebel RE, 1996, WASH QUART, V19, P73