Modeling and simulation of a falling film evaporator for a water vapor heat pump system

被引:14
作者
Hu, Bin [1 ]
Yan, Hongzhi [1 ]
Wang, R. Z. [1 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai 200240, Peoples R China
基金
中国国家自然科学基金;
关键词
Falling film evaporator; Heat transfer tube; Dry patches; Liquid level control; Boundary line; HORIZONTAL TUBE; PERFORMANCE; ARRAYS; R-134A; FLOW;
D O I
10.1016/j.apenergy.2019.113851
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
With the advantages of excellent heat transfer performance and less refrigerant charge, falling film evaporator has been widely used in seawater desalination and other industries. However, due to the practical problems of liquid level control and dry patches interactions, the structure design of falling film evaporator should be optimized for refrigeration applications. To resolve those problems, a simulation model for water-to-water falling film evaporator used in a water vapor heat pump system was conducted in this paper. Through the finite element method, the temperature distribution along the working tubes and the heat exchanger has been obtained. The distribution of heat transfer coefficient along the tube is also investigated to find out the best liquid level control solutions. For an available falling film evaporator with 4 pass working tubes under boiling temperature of 80 degrees C and spraying mass of 0.4 kg.s(-1), it is suggested that 2 pass working tubes should be in falling film region in order to achieve the largest heating capacity. Most important of all, it is proposed that there is an optimal boundary line between full liquid and falling film region. It may provide some suggestions for future design of falling film evaporators.
引用
收藏
页数:8
相关论文
共 25 条
[1]   Numerical simulation and experimental validation of a helical double-pipe vertical condenser [J].
Colorado, D. ;
Hernandez, J. A. ;
Garcia-Valladares, O. ;
Huicochea, A. ;
Siqueiros, J. .
APPLIED ENERGY, 2011, 88 (06) :2136-2145
[2]   Heat transfer of a helical double-pipe vertical evaporator: Theoretical analysis and experimental validation [J].
Colorado-Garrido, D. ;
Santoyo-Castelazo, E. ;
Hernandez, J. A. ;
Garcia-Valladares, O. ;
Siqueiros, J. ;
Juarez-Romero, D. .
APPLIED ENERGY, 2009, 86 (7-8) :1144-1153
[3]  
Cooper M. G., 1984, First U.K. National Conference on Heat Transfer, P785
[4]  
GNIELINSKI V, 1976, INT CHEM ENG, V16, P359
[5]  
Heruaudez JA, 2017, APPL ENERG, V208, P1274
[6]   Water vapor compression and its various applications [J].
Hu, Bin ;
Wu, Di ;
Wang, R. Z. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 98 :92-107
[7]   Study on the effect of refrigerant distributing nonuniformity on the performance of falling-film evaporator with liquid recirculation system [J].
Li, YingLin ;
Wang, Ke ;
Wu, Wei ;
Xia, XueYing ;
Niu, BaoLian ;
Zhang, ZhongBin .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 82 :199-211
[8]  
Liu P.J.P., 1975, The Evaporating Falling
[9]   NOTE ON COMBINED BOILING AND EVAPORATION OF LIQUID-FILMS ON HORIZONTAL TUBES [J].
LORENZ, JJ ;
YUNG, D .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1979, 101 (01) :178-180
[10]  
Lyle O., 1947, EFFICIENT USE STEAM, P1