Evaluation of Bacterial Contamination and Control Methods in Soluble Metalworking Fluids

被引:24
|
作者
Marchand, Genevieve [1 ]
Lavoie, Jacques [1 ]
Racine, Louise [1 ]
Lacombe, Nancy [1 ]
Cloutier, Yves [1 ]
Belanger, Eric [2 ]
Lemelin, Christian [3 ]
Desroches, Jean [4 ]
机构
[1] IRSST, Quebec City, PQ H3A 3C2, Canada
[2] ASP Met Elect, Quebec City, PQ, Canada
[3] GLDEnterprises, Quebec City, PQ, Canada
[4] Magnus, Quebec City, PQ, Canada
关键词
bacteria; contamination; control; metalworking fluids; HYPERSENSITIVITY PNEUMONITIS; OCCUPATIONAL-EXPOSURE; MICROBIAL-GROWTH; ENDOTOXINS; DERMATITIS; WORKERS;
D O I
10.1080/15459621003741631
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the United States, 1.2 million workers are exposed to metalworking fluids. During operations, aerosols are produced and airborne contaminants can be inhaled. Although biocides are used to control the bacterial content of metalworking fluids, they can create health-related problems, and their efficiency remains to be proved. The objectives of this project were (1) to verify whether rigorous cleaning according to a standard protocol could reduce microbial contamination and (2) whether the use of biocides with different spectra could reduce the bacterial population. Four similar machines producing similar components were evaluated; a specific treatment was applied to each machine. The machine used as a control (1) was thoroughly cleaned prior to sampling, (2) did not undergo any major cleaning afterward, and (3) was operated without the use of any biocide. A major cleaning is a protocol described and recommended by the fluid manufacturer and was performed on the three other machines, two of which were subsequently treated with biocides weekly. Fluid samples from the four lathes were collected weekly during a 6-month period, and total bacterial and cultivable Gram-negative bacteria were analyzed for each sample. Major cleaning of the machines (120-4) did not significantly reduce the concentration of bacteria in the cutting fluids when compared with the control machine (120-3), which had not undergone major cleaning. The concentrations of total bacteria were in the 106 CFU/mL range for these two lathes; however, a reduction in the total number of fluid changes was observed for this machine. Bacterial flora in the cutting fluids was significantly controlled with the use of biocides. Bacteria concentrations were in the 103-105 CFU/mL range for the lathes with the use of biocides. Since thorough cleaning is insufficient and biocides are recognized as being responsible for some worker health problems, other avenues for controlling bacterial flora in cutting fluids should be evaluated to reduce worker exposure to their bacterial contaminants.
引用
收藏
页码:358 / 366
页数:9
相关论文
共 50 条
  • [11] CONTROLLING BACTERIAL GROWTH IN METALWORKING FLUIDS.
    Tacchi, K.J.
    Tooling and production, 1985, 51 (07): : 68 - 69
  • [12] Membrane filtration studies of inversely soluble model metalworking fluids
    Misra, SK
    Sköld, RO
    SEPARATION SCIENCE AND TECHNOLOGY, 1999, 34 (01) : 53 - 67
  • [13] An evaluation of analytical methods, air sampling techniques, and airborne occupational exposure of metalworking fluids
    Verma, DK
    Shaw, DS
    Shaw, ML
    Julian, JA
    McCollin, SA
    des Tombe, K
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2006, 3 (02) : 53 - 66
  • [14] ECONOMICAL EVALUATION OF THE APPLICATION OF WATERMISCIBLE METALWORKING FLUIDS
    MANG, T
    TWEEBEEKE, A
    LUBRICATION ENGINEERING, 1983, 39 (06): : 353 - 357
  • [15] Performance evaluation of metalworking fluids based on microorganisms
    Seidel B.
    Rabenstein A.
    Redetzky M.
    Wagner A.
    Brinksmeier E.
    Production Engineering, 2017, 11 (1) : 41 - 49
  • [16] Turbidimetric Spectroscopy for the Evaluation of Metalworking Fluids Stability
    Glasse, Benjamin
    Fritsching, Udo
    Koch, Thomas
    De Paiva, Jose L.
    Guardani, Roberto
    TRIBOLOGY & LUBRICATION TECHNOLOGY, 2015, 71 (03) : 46 - +
  • [17] Turbidimetric Spectroscopy for the Evaluation of Metalworking Fluids Stability
    Glasse, Benjamin
    Fritsching, Udo
    Koch, Thomas
    De Paiva, Jose L.
    Guardani, Roberto
    TRIBOLOGY TRANSACTIONS, 2012, 55 (02) : 237 - 244
  • [18] A differential adenosine triphosphate test method for differentiating between bacterial and fungal contamination in water-miscible metalworking fluids
    Passman, Frederick J.
    Kuenzi, Peter
    INTERNATIONAL BIODETERIORATION & BIODEGRADATION, 2015, 99 : 129 - 137
  • [19] A COMPARATIVE EVALUATION OF METHODS FOR DETERMINING THE BACTERIAL CONTAMINATION OF SURFACES
    ANGELOTTI, R
    FOTER, MJ
    LEWIS, KH
    FOOD TECHNOLOGY, 1957, 11 (04) : 22 - 22
  • [20] EFFECTS OF TSCA ON THE METALWORKING FLUIDS INDUSTRY - INCREASED AWARENESS OF NITROSAMINE CONTAMINATION
    FRIBUSH, HM