Pachymetric mapping with Fourier-domain optical coherence tomography

被引:70
作者
Li, Yan
Tang, Maolong
Zhang, Xinbo
Salaroli, Camila H.
Ramos, Jose L.
Huang, David [1 ]
机构
[1] Doheny Eye Inst, Ctr Ophthalm Opt & Lasers, Los Angeles, CA 90033 USA
关键词
CENTRAL CORNEAL THICKNESS; IN-SITU KERATOMILEUSIS; ULTRASOUND PACHYMETRY; HIGH-SPEED; ORBSCAN-II; REFRACTIVE SURGERY; VISANTE; KERATOCONUS; AGREEMENT; PENTACAM;
D O I
10.1016/j.jcrs.2009.11.016
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the repeatability of Fourier-domain optical coherence tomography (OCT) pachymetric mapping and compare central corneal thickness (CCT) measurements by OCT, ultrasound pachymetry, and scanning-slit tomography. SETTING: Doheny Eye Institute, University of Southern California, Los Angeles, California, USA. METHODS: A Fourier-domain OCT system was used to map the corneal thickness in normal eyes with scans centered on the corneal vertex or the pupil. Repeatability of central and pericentral map sectors was assessed by pooled standard deviation. The CCT measurements were compared between the OCT, ultrasound, and scanning-slit devices. RESULTS: Pupil centration (SD: 1.3 mu m central, 1.8 to 3.8 mu m pericentral) provided better repeatability than vertex centration (SD: 1.7 mu m central, 2.4 to 5.7 mu m pericentral) in all sectors (P<.035). The mean CCT was 536.9 mu m +/- 27.0 (SD) by OCT, 556.6 +/- 30.5 mu m by ultrasound, and 537.2 +/- 32.6 mu m by scanning-slit tomography (acoustic factor 0.92). The CCT measured by OCT was significantly thinner than by ultrasound pachymetry (P = .007; mean difference -19.7 mu m; 95% limits of agreement [LoA], -40.4 to 0.9 mu m) but not than by scanning-slit tomography (P = .2637; mean difference -0.3 mu m; 95% LoA, -24.0 to 23.5 mu m). The CCT by OCT correlated well with ultrasound and scanning-slit CCTs (r = 0.940 and r = 0.934, respectively). CONCLUSION: Pachymetric mapping with Fourier-domain OCT was highly repeatable. Repeatability was better with pupil-centered scans than with corneal vertex centered scans. Ultrasound pachymetry, Fourier-domain OCT, and scanning-slit tomography should not be used interchangeably for CCT assessment.
引用
收藏
页码:826 / 831
页数:6
相关论文
共 24 条
[1]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[2]   In vivo corneal high-speed, ultra-high-resolution optical coherence tomography [J].
Christopoulos, Viki ;
Kagemann, Larry ;
Wollstein, Gadi ;
Ishikawa, Hi. Roshi ;
Gabriele, Michelle L. ;
Wojtkowski, Maciej ;
Srinivasan, Vivek ;
Fujimoto, James G. ;
Duker, Jay S. ;
Dhaliwal, Deepinder K. ;
Schuman, Joel S. .
ARCHIVES OF OPHTHALMOLOGY, 2007, 125 (08) :1027-1035
[3]   Central corneal thickness measurement with Pentacam, Orbscan II, and ultrasound devices before and after laser refractive surgery for myopia [J].
Hashemi, Hassan ;
Mehravaran, Shiva .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (10) :1701-1707
[4]   Central corneal thickness measurements using Orbscan II, Visante, ultrasound, and Pentacam pachymetry after laser in situ keratomileusis for myopia [J].
Ho, Thomas ;
Cheng, Arthur C. K. ;
Rao, Srinivas K. ;
Lau, Silvania ;
Leung, Chris K. S. ;
Lam, Dennis S. C. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (07) :1177-1182
[5]  
Huang, 2008, ANTERIOR SEGMENT OPT, P165
[6]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[7]   High-speed optical coherence tomography of corneal opacities [J].
Khurana, Rahul N. ;
Li, Yan ;
Tang, Maolong ;
Lai, Michael M. ;
Huang, David .
OPHTHALMOLOGY, 2007, 114 (07) :1278-1285
[8]   Comparison of central corneal thickness using anterior segment optical coherence tomography vs ultrasound pachymetry [J].
Kim, Hanna Y. ;
Budenz, Donald L. ;
Lee, Pak S. ;
Feuer, William J. ;
Barton, Keith .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 145 (02) :228-232
[9]  
Kozak I, 2003, J REFRACT SURG, V19, P149
[10]   Agreement among 3 methods to measure corneal thickness: Ultrasound pachymetry, Orbscan II, and Visante anterior segment optical coherence tomography [J].
Li, Emmy Y. M. ;
Mohamed, Shaheeda ;
Leung, Christopher K. S. ;
Rao, Srinivas K. ;
Cheng, Arthur C. K. ;
Cheung, Carol Y. L. ;
Lam, Dennis S. C. .
OPHTHALMOLOGY, 2007, 114 (10) :1842-1847