Accuracy in catheter reconstruction in computed tomography planning of high dose rate prostate brachytherapy

被引:6
作者
Fung, AYC [1 ]
Zaider, M [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, New York, NY 10021 USA
关键词
reconstruction; CT; HDR; prostate; brachytherapy;
D O I
10.1118/1.1288670
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In high dose rate prostate brachytherapy, inadequate reconstruction of catheter geometry in treatment planning may result in erroneous dose delivery. Catheters may be digitized with: (1) Parallel reconstruction: digitized at only one point and assumed parallel and horizontal; (3) Straight reconstruction: digitized at both ends and assumed straight while at an angle; (3) Slice-by-slice reconstruction: digitized on all slices to obtain exact geometry. Our results show that individual catheters are often not parallel to each other, but fairly straight. Parallel reconstruction is the least accurate for dosimetric planning, while slice-by-slice reconstruction is time-consuming. Straight (two-point) reconstruction represents a balance between accuracy and efficiency. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)01509-1].
引用
收藏
页码:2165 / 2167
页数:3
相关论文
共 2 条
[1]   CONCURRENT TREATMENT PLANNING FOR OUTPATIENT HIGH-DOSE-RATE PROSTATE TEMPLATE IMPLANTS [J].
EDMUNDSON, GK ;
RIZZO, NR ;
TEAHAN, M ;
BRABBINS, D ;
VICINI, FA ;
MARTINEZ, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (05) :1215-1223
[2]   A system for nonradiographic source localization and real-time planning of intraoperative high dose rate brachytherapy [J].
Watanabe, Y ;
Anderson, LL .
MEDICAL PHYSICS, 1997, 24 (12) :2014-2023