Stability and dynamic analysis of doubly-fed variable speed pump turbine governing system based on Hopf bifurcation theory

被引:33
作者
Gao, Chunyang [1 ]
Yu, Xiangyang [1 ,2 ]
Nan, Haipeng [1 ,2 ]
Men, Chuangshe [1 ,2 ]
Zhao, Peiyu [1 ]
Cai, Qingsen [1 ]
Fu, Jianing [1 ]
机构
[1] Xian Univ Technol, Coll Water Conservancy & Hydropower Engn, Xian 710048, Shaanxi, Peoples R China
[2] Xian Univ Technol, State Key Lab Ecohydraul Northwest Arid Reg, Xian 710048, Shaanxi, Peoples R China
基金
国家重点研发计划;
关键词
Pumped storage; Variable speed; Stability; Hopf bifurcation; ORDER PID CONTROLLER; TIP LEAKAGE VORTEX; MIXED-FLOW PUMP; STORAGE UNIT; REGULATING SYSTEM; DESIGN; HYDRO; MODEL; STRATEGIES; OPERATION;
D O I
10.1016/j.renene.2021.05.015
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The stability of a doubly-fed variable speed pump-turbine governing system (VSPTGS) under the condition of small power disturbance was investigated. First, a novel model of the VSPTGS in turbine mode and pump mode is proposed based on the electromechanical transient model of the doubly-fed induction generator (DFIG). Then, the algebraic stability criteria of the system in turbine mode and pump mode are derived using Hopf bifurcation theory. Furthermore, the stability domain of the speed controller parameters is obtained when the power controller parameters are determined, and the dynamic behavior of the system is analyzed using bifurcation diagrams and numerical simulation. Finally, the power controller parameters are varied to study the influence of these parameters on the stability domain. The results show that Hopf bifurcation of a VSPTGS is subcritical. When the parameters of the power controller are fixed, the stability domain in pump mode is larger than that in turbine mode. The stability in turbine mode only depends on the speed controller parameters, whereas the stability in pump mode depends on both the speed controller parameters and the power controller parameters. (c) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页码:568 / 579
页数:12
相关论文
共 46 条
[1]   Advanced Vector Control Design for DFIM-Based Hydropower Storage for Fault Ride-Through Enhancement [J].
Bidgoli, Mohsen Alizadeh ;
Mohammadpour, Hossein Ali ;
Bathaee, Seyed Mohammad Taghi .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2015, 30 (04) :1449-1459
[2]   Nonlinear dynamic analysis for a Francis hydro-turbine governing system and its control [J].
Chen, Diyi ;
Ding, Cong ;
Do, Younghae ;
Ma, Xiaoyi ;
Zhao, Hua ;
Wang, Yichen .
JOURNAL OF THE FRANKLIN INSTITUTE-ENGINEERING AND APPLIED MATHEMATICS, 2014, 351 (09) :4596-4618
[3]   Low-Frequency Instability Induced by Hopf Bifurcation in a Single-Phase Converter Connected to Non-Ideal Power Grid [J].
Chen, Hong ;
Yu, Wenqian ;
Liu, Zhigang ;
Yan, Qixiang ;
Tasiu, Ibrahim ;
Han, Zhiwei .
IEEE ACCESS, 2020, 8 :62871-62882
[4]   Design of a fractional order PID controller for hydraulic turbine regulating system using chaotic non-dominated sorting genetic algorithm II [J].
Chen, Zhihuan ;
Yuan, Xiaohui ;
Ji, Bin ;
Wang, Pengtao ;
Tian, Hao .
ENERGY CONVERSION AND MANAGEMENT, 2014, 84 :390-404
[5]  
Cheng Yuanchu, 2010, Automatic Regulation of Water Turbine
[6]   Low voltage ride-through strategies for doubly fed induction machine pumped storage system under grid faults [J].
Damdoum, Amel ;
Slama-Belkhodja, Ilhem ;
Pietrzak-David, Maria ;
Debbou, Mustapha .
RENEWABLE ENERGY, 2016, 95 :248-262
[7]   A Fast High-Precision Model of the Doubly-Fed Pumped Storage Unit [J].
Gao, Chunyang ;
Yu, Xiangyang ;
Nan, Haipeng ;
Men, Chuangshe ;
Fu, Jianing .
JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2021, 16 (02) :797-808
[8]   Analysis of the Primary Control System of a Hydropower Plant in Isolated Model [J].
Gomes Zoby, Maria Regina ;
Yanagihara, Jurandir Itizo .
JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2009, 31 (01) :5-11
[9]   Nonlinear modeling and dynamic control of hydro-turbine governing system with upstream surge tank and sloping ceiling tailrace tunnel [J].
Guo, Wencheng ;
Yang, Jiandong ;
Chen, Jieping ;
Wang, Mingjiang .
NONLINEAR DYNAMICS, 2016, 84 (03) :1383-1397
[10]   Influence of rotating speed on tip leakage vortex in a mixed flow pump as turbine at pump mode [J].
Han, Yadong ;
Tan, Lei .
RENEWABLE ENERGY, 2020, 162 :144-150