Effective Cardiac Index and Systemic-Pulmonary Collaterals Evaluated by Cardiac Magnetic Resonance Late After Fontan Palliation

被引:13
作者
Ali, Lamia Ait [1 ]
Cadoni, Alessandra [2 ]
Rossi, Giuseppe [1 ]
Keilberg, Petra [3 ]
Passino, Claudio [4 ,5 ]
Festa, Pierluigi [6 ]
机构
[1] CNR, Inst Clin Physiol, Massa, Italy
[2] Brotzu Hosp, Pediat Cardiol, Pediat Cardiol & GUCH Unit, Cagliari, Italy
[3] Fdn G Monasterio CNR Reg Toscana, MRI Lab, Massa Pisa, Italy
[4] Fdn G Monasterio CNR Reg Toscana, Dept Cardiol & Cardiovasc Med, Massa Pisa, Italy
[5] Scuola Super Sant Anna, Pisa, Italy
[6] Fdn G Monasterio CNR Reg Toscana, Pediat Cardiol & GUCH Unit, Massa Pisa, Italy
关键词
AORTOPULMONARY COLLATERALS; POST-FONTAN; BLOOD-FLOW; COMPLETION; QUANTIFICATION; OUTCOMES;
D O I
10.1016/j.amjcard.2017.03.040
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The regulation of cardiac output in the Fontan circuit is not completely understood. Systemic-pulmonary collaterals (SPCs) are frequent in patients with univentricular heart, and their clinical significance and management remain controversial. The aims of our study were to identify factors associated with SPCs' flow at late follow-up after Fontan and evaluate the relation between SPCs flow (QSPCs) and the effective cardiac index (CI). From our cardiac magnetic resonance database, we identified all Fontan patients with a complete set of flow measurements allowing calculation of QSPCs and effective CI. QSPCs was calculated as (left pulmonary veins flow + right pulmonary veins flow) - (right pulmonary artery flow + left pulmonary artery flow). Effective CI was calculated as (Aortic flow (QAo) - QSPCs)/BSA. Medical, surgical history, and clinical status were recorded. Sixty-four post-Fontan patients (36 male; mean age 19 +/- 10 years) were included in the study. Median QSPCs was 0.7 L/min/m(2) (interquartile [IQ] range 0.386-0.983) accounting for a median of 21% (IQ range 13-28) of aortic flow. The effective CI in our population was 2.4 +/- 0.6 L/min/m(2). QSPCs inversely correlate with left pulmonary artery area (r =-0.37, p = 0.004) and total antegrade pulmonary flow (r = -0.32, p = 0.01). QSPCs correlate with indexed aortic flow (r = 0.6, p<0.001) and inversely correlate with effective CI (r = -0.39, p = 0.002). Effective CI inversely correlates with age at study and age at the Fontan palliation (r = -0.35, p = 0.005, and r = -0.29, p = 0.02, respectively) and positively with ventricular ejection fraction (r = 0.3, p = 0.01). In conclusion, SPCs are common in Fontan patients, correlate inversely with effective CI, and are associated with a reduced antegrade pulmonary flow. In cardiac magnetic resonance evaluation of post-Fontan patients, effective CI should be taken into account rather than the total CI. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:2069 / 2072
页数:4
相关论文
共 19 条
[1]   Systematic-to-pulmonary collaterals: A source of flow energy loss in Fontan physiology [J].
Ascuitto, RJ ;
Ross-Ascuitto, NT .
PEDIATRIC CARDIOLOGY, 2004, 25 (05) :472-481
[2]   Practice variability and outcomes of coil embolization of aortopulmonary collaterals before fontan completion: A report from the Pediatric Heart Network Fontan Cross-Sectional Study [J].
Banka, Puja ;
Sleeper, Lynn A. ;
Atz, Andrew M. ;
Cowley, Collin G. ;
Gallagher, Dianne ;
Gillespie, Matthew J. ;
Graham, Eric M. ;
Margossian, Renee ;
McCrindle, Brian W. ;
Sang, Charlie J. ;
Williams, Ismee A. ;
Newburger, Jane W. .
AMERICAN HEART JOURNAL, 2011, 162 (01) :125-130
[3]   Aortopulmonary collateral flow in the Fontan patient: Does it matter? [J].
Bradley, SM ;
McCall, MM ;
Sistino, JJ ;
Radtke, WAK .
ANNALS OF THORACIC SURGERY, 2001, 72 (02) :408-415
[4]   Cardiac magnetic resonance versus routine cardiac catheterization before bidirectional Glenn anastomosis: Long-term follow-up of a prospective randomized trial [J].
Brown, David W. ;
Gauvreau, Kimberlee ;
Powell, Andrew J. ;
Lang, Peter ;
del Nido, Pedro J. ;
Odegard, Kirsten C. ;
Geva, Tal .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 146 (05) :1172-1178
[5]   Acute Effects of Embolizing Systemic-to-Pulmonary Arterial Collaterals on Blood Flow in Patients With Superior Cavopulmonary Connections A Pilot Study [J].
Dori, Yoav ;
Glatz, Andrew C. ;
Hanna, Brian D. ;
Gillespie, Matthew J. ;
Harris, Matthew A. ;
Keller, Marc S. ;
Fogel, Mark A. ;
Rome, Jonathan J. ;
Whitehead, Kevin K. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (01) :101-106
[6]  
Festa P, 2009, CONGENITAL HEART DEF, V3
[7]   Quantification of Systemic-to-Pulmonary Artery Collateral Flow Challenges and Opportunities [J].
Geva, Tal .
CIRCULATION-CARDIOVASCULAR IMAGING, 2012, 5 (02) :175-177
[8]   The Fontan circulation: who controls cardiac output? [J].
Gewillig, Marc ;
Brown, Stephen C. ;
Eyskens, Benedicte ;
Heying, Ruth ;
Ganame, Javier ;
Budts, Werner ;
La Gerche, Andre ;
Gorenflo, Matthias .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2010, 10 (03) :428-433
[9]   Systemic-to-Pulmonary Collateral Flow, as Measured by Cardiac Magnetic Resonance Imaging, Is Associated With Acute Post-Fontan Clinical Outcomes [J].
Glatz, Andrew C. ;
Rome, Jonathan J. ;
Small, Adam J. ;
Gillespie, Matthew J. ;
Dori, Yoav ;
Harris, Matthew A. ;
Keller, Marc S. ;
Fogel, Mark A. ;
Whitehead, Kevin K. .
CIRCULATION-CARDIOVASCULAR IMAGING, 2012, 5 (02) :218-225
[10]   Aortopulmonary collateral flow volume affects early postoperative outcome after Fontan completion: A multimodality study [J].
Grosse-Wortmann, Lars ;
Drolet, Christian ;
Dragulescu, Andreea ;
Kotani, Yasuhiro ;
Chaturvedi, Rajiv ;
Lee, Kyong-Jin ;
Mertens, Luc ;
Taylor, Katherine ;
La Rotta, Gustavo ;
van Arsdell, Glen ;
Redington, Andrew ;
Yoo, Shi-Joon .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 144 (06) :1329-1336