Characterization of copper in uterine fluids of patients who use the copper T-380A intrauterine device

被引:44
|
作者
Arancibia, V [1 ]
Peña, C
Allen, HE
Lagos, G
机构
[1] Pontificia Univ Catolica Chile, Fac Quim, Santiago, Chile
[2] Univ Delaware, Dept Civil & Environm Engn, Newark, DE USA
[3] Pontificia Univ Catolica Chile, Fac Ingn, Santiago, Chile
关键词
copper; IUD; uterine fluid;
D O I
10.1016/S0009-8981(03)00124-4
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The copper intrauterine device (IUD) is a highly effective method of contraception that requires the dissolution of the copper into uterine cavity. However, there is little information about the amount and form of copper in the fluid and whether the presence of this element produces any change in the protein concentration. Methods: Twenty-seven women were divided into three groups that had used IUD for about 6 months, 1 year and greater than or equal to 3 years. The samples were collected during the proliferative phase (Pp), secretory phase (Sp) and menstruation (M). Square-wave anodic stripping voltammetry (SWASV), cyclic voltammetry (CV), high performance liquid chromatography (HPLC) and atomic absorption spectrometry (AAS) were used in this study. Results: Total copper concentrations were between 3.9 and 19.1 mug/ml. The mean and standard deviations were as follows: 6 months, 11.4 +/- 4.7 mug/ml of copper; 1 year, 11.5 +/- 7.0 mug/ml of copper; and 3 years, 6.2 +/- 1.5 mug/ml of copper. Total proteins were quantified by measuring the area under the chromatographic peaks. The mean areas obtained with uterine fluid samples from women who used IUDs for 6 months, 1 year and 3 years were 290,013, 538,934 and 201,863 arbitrary units (AU), respectively. The control sample was only 22323. Conclusions: The amount of copper released from IUD, although high, is in the form of complexes with proteins. IUDs have a constant copper release for at least 6-12 months. Copper(I) was not detected in the fluid. Copper induces a change in the total protein concentration. The amount of copper released and the amount of proteins is slightly larger during the menstrual stage. (C) 2003 Elsevier Science B.V All rights reserved.
引用
收藏
页码:69 / 78
页数:10
相关论文
共 23 条
  • [1] Changes in distribution patterns of integrins in endometrium in copper T380 intrauterine device users
    Oruç, S
    Vatansever, HS
    Karaer, Ö
    Eskicioglu, F
    Narlikuyu, B
    ACTA HISTOCHEMICA, 2005, 107 (02) : 95 - 103
  • [2] Characterization of copper corrosion products originated in simulated uterine fluids and on packaged intrauterine devices
    J. M. Bastidas
    N. Mora
    E. Cano
    J. L. Polo
    Journal of Materials Science: Materials in Medicine, 2001, 12 : 391 - 397
  • [3] Changes in copper and zinc serum levels in women wearing a copper TCu-380A intrauterine device
    Imani, Somaieh
    Moghaddam-Banaem, Lida
    Roudbar-Mohammadi, Shahla
    Asghari-Jafarabadi, Mohammad
    EUROPEAN JOURNAL OF CONTRACEPTION AND REPRODUCTIVE HEALTH CARE, 2014, 19 (01) : 45 - 50
  • [4] Copper T380A intrauterine device for emergency contraception: a prospective, multicentre, cohort clinical trial
    Wu, S.
    Godfrey, E. M.
    Wojdyla, D.
    Dong, J.
    Cong, J.
    Wang, C.
    von Hertzen, H.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2010, 117 (10) : 1205 - 1210
  • [5] Contraceptive failure with Copper T380A intrauterine device (IUD): A single tertiary center experience
    Ekiz, Ali
    Ozkose, Burak
    Yucel, Burak
    Eftal, Muhittin
    Adanur, Ahmet
    Yildirim, Gokhan
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2016, 32 (05) : 1087 - 1091
  • [6] Copper T380 intrauterine device for emergency contraception: highly effective at any time in the menstrual cycle
    Turok, D. K.
    Godfrey, E. M.
    Wojdyla, D.
    Dermish, A.
    Torres, L.
    Wu, S. C.
    HUMAN REPRODUCTION, 2013, 28 (10) : 2672 - 2676
  • [7] Comparison of uterine artery blood flow with levonorgestrel intrauterine system and copper intrauterine device
    Haliloglu, Berna
    Celik, Aygen
    Ilter, Erdin
    Bozkurt, Serpil
    Ozekici, Umit
    CONTRACEPTION, 2011, 83 (06) : 578 - 581
  • [8] Alterations in copper homeostasis and oxidative stress biomarkers in women using the intrauterine device TCu380A
    Arnal, Nathalie
    de Alaniz, Maria J. T.
    Marra, Carlos A.
    TOXICOLOGY LETTERS, 2010, 192 (03) : 373 - 378
  • [9] Effects of levonorgestrel-releasing intrauterine system and T380A intrauterine copper device on dysmenorrhea and days of bleeding in women with and without adenomyosis
    Kelekci, Sefa
    Kelekci, Kiymet Handan
    Yilmaz, Bulent
    CONTRACEPTION, 2012, 86 (05) : 458 - 463
  • [10] A randomized comparison of a novel nitinol-frame low-dose-copper intrauterine contraceptive and a copper T380S intrauterine contraceptive
    Reeves, Matthew F.
    Katz, Bob H.
    Canela, Juan M.
    Hathaway, Mark J.
    Tal, Michael G.
    CONTRACEPTION, 2017, 95 (06) : 544 - 548