Characterization of copper in uterine fluids of patients who use the copper T-380A intrauterine device

被引:44
作者
Arancibia, V [1 ]
Peña, C
Allen, HE
Lagos, G
机构
[1] Pontificia Univ Catolica Chile, Fac Quim, Santiago, Chile
[2] Univ Delaware, Dept Civil & Environm Engn, Newark, DE USA
[3] Pontificia Univ Catolica Chile, Fac Ingn, Santiago, Chile
关键词
copper; IUD; uterine fluid;
D O I
10.1016/S0009-8981(03)00124-4
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The copper intrauterine device (IUD) is a highly effective method of contraception that requires the dissolution of the copper into uterine cavity. However, there is little information about the amount and form of copper in the fluid and whether the presence of this element produces any change in the protein concentration. Methods: Twenty-seven women were divided into three groups that had used IUD for about 6 months, 1 year and greater than or equal to 3 years. The samples were collected during the proliferative phase (Pp), secretory phase (Sp) and menstruation (M). Square-wave anodic stripping voltammetry (SWASV), cyclic voltammetry (CV), high performance liquid chromatography (HPLC) and atomic absorption spectrometry (AAS) were used in this study. Results: Total copper concentrations were between 3.9 and 19.1 mug/ml. The mean and standard deviations were as follows: 6 months, 11.4 +/- 4.7 mug/ml of copper; 1 year, 11.5 +/- 7.0 mug/ml of copper; and 3 years, 6.2 +/- 1.5 mug/ml of copper. Total proteins were quantified by measuring the area under the chromatographic peaks. The mean areas obtained with uterine fluid samples from women who used IUDs for 6 months, 1 year and 3 years were 290,013, 538,934 and 201,863 arbitrary units (AU), respectively. The control sample was only 22323. Conclusions: The amount of copper released from IUD, although high, is in the form of complexes with proteins. IUDs have a constant copper release for at least 6-12 months. Copper(I) was not detected in the fluid. Copper induces a change in the total protein concentration. The amount of copper released and the amount of proteins is slightly larger during the menstrual stage. (C) 2003 Elsevier Science B.V All rights reserved.
引用
收藏
页码:69 / 78
页数:10
相关论文
共 27 条
[1]  
*AM CANC SOC, 2001, KEY STAT ENDOMETRIAL
[2]   Copper corrosion-simulated uterine solutions [J].
Bastidas, JM ;
Cano, E ;
Mora, N .
CONTRACEPTION, 2000, 61 (06) :395-399
[3]   Characterization of copper corrosion products originated in simulated uterine fluids and on packaged intrauterine devices [J].
Bastidas, JM ;
Mora, N ;
Cano, E ;
Polo, JL .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2001, 12 (05) :391-397
[4]   Characterization of corrosion products on a copper-containing intrauterine device during storage at room temperature [J].
Bastidas, JM ;
Simancas, T .
BIOMATERIALS, 1997, 18 (03) :247-250
[5]  
CASSLEN B, 1986, J REPROD MED, V31, P506
[6]   Polarographic determination of half-wave potentials for copper-organic complexes in seawater [J].
Croot, PL ;
Moffett, JW ;
Luther, GW .
MARINE CHEMISTRY, 1999, 67 (3-4) :219-232
[8]   Concentrations of placental protein 14 in uterine flushings from infertile women: validation of the collection technique and method of expression of results [J].
Hamilton, JA ;
Iles, RK ;
Gunn, LK ;
Wilson, CMY ;
Lower, AM ;
Chard, T ;
Grudzinskas, JG .
HUMAN REPRODUCTION, 1998, 13 (12) :3357-3362
[9]   Cooperative binding of copper(I) to the metal binding domains in Menkes disease protein [J].
Jensen, PY ;
Bonander, N ;
Moller, LB ;
Farver, O .
BIOCHIMICA ET BIOPHYSICA ACTA-PROTEIN STRUCTURE AND MOLECULAR ENZYMOLOGY, 1999, 1434 (01) :103-113
[10]   MECHANISM OF ACTION OF INTRAUTERINE-DEVICES - BIOCHEMICAL-CHANGES [J].
JOHANNISSON, E .
CONTRACEPTION, 1987, 36 (01) :11-22