Gait analysis system for assessment of dynamic loading axis of the knee

被引:14
作者
Kawakami, H
Sugano, N
Yonenobu, K
Yoshikawa, H
Ochi, T
Hattori, A
Suzuki, N
机构
[1] Osaka Univ, Grad Sch Med, Dept Med Robot & Image Sci, Suita, Osaka 5650871, Japan
[2] Osaka Univ, Grad Sch Med, Dept Orthopaed Surg, Suita, Osaka, Japan
[3] Osaka Minami Natl Hosp, Dept Orthopaed Surg, Osaka, Japan
[4] Jikei Univ, Sch Med, Inst High Dimens Med Imaging, Komae, Tokyo, Japan
基金
日本学术振兴会;
关键词
gait analysis system; locus of dynamic loading axis; knee OA; motion capture analysis open MRI;
D O I
10.1016/j.gaitpost.2004.01.002
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The purpose of this study was (1) to demonstrate a computer-assisted gait analysis system that can visualize the locus of the dynamic loading axis on the proximal tibia joint surface, and (2) to assess the accuracy of this system in a patient with bilateral knee osteoarthritis (OA). This system uses force plate data, CT skeletal structure data and motion capture data obtained from an infrared position sensor. The relative positions between bones and markers were used to calculate skeletal model movement based on movement of the markers. The locus of the dynamic loading axis on the knee joint was defined as the point on the proximal tibia joint Surface that intersected with the loading axis of the lower limb, which passed through the centre of the femoral head and the centroid of multiple points surrounded by the distal tibia joint surface contour. To assess the accuracy of this system, open MRI was used to evaluate positions of skin markers against bones in six healthy volunteers. The locus in a patient was affected by differences between the varus knee with medial compartment OA on the non-operative side and the knee treated with high tibial osteotomy (HTO) on the opposite side. At knee flexion angles of 0degrees, 15degrees and 30degrees, the mean value of measurement error for point locations on the locus was within 5.6% of joint width in the lateral direction (JWLD) on the proximal tibia joint. This system can provide clinically useful information for evaluation of the dynamic loading axis on the knee joint surface. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:125 / 130
页数:6
相关论文
共 15 条
[1]   Correcting for deformation in skin-based marker systems [J].
Alexander, EJ ;
Andriacchi, TP .
JOURNAL OF BIOMECHANICS, 2001, 34 (03) :355-361
[2]   A Point Cluster Method for In Vivo Motion Analysis: Applied to a Study of Knee Kinematics [J].
Andriacchi, TP ;
Alexander, EJ ;
Toney, MK ;
Dyrby, C .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1998, 120 (06) :743-749
[3]   A METHOD FOR REGISTRATION OF 3-D SHAPES [J].
BESL, PJ ;
MCKAY, ND .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) :239-256
[4]   Surface-marker cluster design criteria for 3-D bone movement reconstruction [J].
Cappozzo, A ;
Cappello, A ;
DellaCroce, U ;
Pensalfini, F .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (12) :1165-1174
[5]   Position and orientation in space of bones during movement: Experimental artefacts [J].
Cappozzo, A ;
Catani, F ;
Leardini, A ;
Benedetti, MG ;
DellaCroce, U .
CLINICAL BIOMECHANICS, 1996, 11 (02) :90-100
[6]   NORMATIVE DATA OF KNEE-JOINT MOTION AND GROUND REACTION FORCES IN ADULT LEVEL WALKING [J].
CHAO, EY ;
LAUGHMAN, RK ;
SCHNEIDER, E ;
STAUFFER, RN .
JOURNAL OF BIOMECHANICS, 1983, 16 (03) :219-233
[7]   The knee adduction moment during gait in subjects with knee osteoarthritis is more closely correlated with static alignment than radiographic disease severity, toe out angle and pain [J].
Hurwitz, DE ;
Ryals, AB ;
Case, JP ;
Block, JA ;
Andriacchi, TP .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2002, 20 (01) :101-107
[8]   3-DIMENSIONAL KINEMATICS OF THE HUMAN KNEE DURING WALKING [J].
LAFORTUNE, MA ;
CAVANAGH, PR ;
SOMMER, HJ ;
KALENAK, A .
JOURNAL OF BIOMECHANICS, 1992, 25 (04) :347-357
[9]   Skin movement artefact assessment and compensation in the estimation of knee-joint kinematics [J].
Lucchetti, L ;
Cappozzo, A ;
Cappello, A ;
Della Croce, U .
JOURNAL OF BIOMECHANICS, 1998, 31 (11) :977-984
[10]  
MIKULICZ J, 1878, ARCH ANAT