Issues involved in the quantitative 3D imaging of proton doses using optical CT and chemical dosimeters

被引:20
作者
Doran, Simon [1 ,2 ]
Gorjiara, Tina [3 ]
Kacperek, Andrzej [4 ]
Adamovics, John [5 ]
Kuncic, Zdenka [6 ]
Baldock, Clive [6 ]
机构
[1] CRUK Canc Imaging Ctr, Inst Canc Res, London, England
[2] Univ Surrey, Dept Phys, Guildford, Surrey, England
[3] Royal Prince Alfred Hosp, Camperdown, NSW 2050, Australia
[4] Clatterbridge Canc Ctr, Wirral, Merseyside, England
[5] Rider Univ, Dept Biol & Chem, Lawrenceville, NJ 08648 USA
[6] Univ Sydney, Sch Phys, Inst Med Phys, Sydney, NSW 2006, Australia
基金
英国工程与自然科学研究理事会;
关键词
optical CT; proton therapy; PRESAGE; POLYMER GEL DOSIMETER; DEPENDENCE; PRESAGE(R); APPARATUS; WATER; BEAMS;
D O I
10.1088/0031-9155/60/2/709
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dosimetry of proton beams using 3D imaging of chemical dosimeters is complicated by a variation with proton linear energy transfer (LET) of the dose-response (the so-called 'quenching effect'). Simple theoretical arguments lead to the conclusion that the total absorbed dose from multiple irradiations with different LETs cannot be uniquely determined from postirradiation imaging measurements on the dosimeter. Thus, a direct inversion of the imaging data is not possible and the proposition is made to use a forward model based on appropriate output from a planning system to predict the 3D response of the dosimeter. In addition to the quenching effect, it is well known that chemical dosimeters have a non-linear response at high doses. To the best of our knowledge it has not yet been determined how this phenomenon is affected by LET. The implications for dosimetry of a number of potential scenarios are examined. Dosimeter response as a function of depth (and hence LET) was measured for four samples of the radiochromic plastic PRESAGE (R), using an optical computed tomography readout and entrance doses of 2.0 Gy, 4.0 Gy, 7.8 Gy and 14.7 Gy, respectively. The dosimeter response was separated into two components, a single-exponential low-LET response and a LET-dependent quenching. For the particular formulation of PRESAGE (R) used, deviations from linearity of the dosimeter response became significant for doses above approximately 16 Gy. In a second experiment, three samples were each irradiated with two separate beams of 4 Gy in various different configurations. On the basis of the previous characterizations, two different models were tested for the calculation of the combined quenching effect from two contributions with different LETs. It was concluded that a linear superposition model with separate calculation of the quenching for each irradiation did not match the measured result where two beams overlapped. A second model, which used the concept of an 'effective dose' matched the experimental results more closely. An attempt was made to measure directly the quench function for two proton beams as a function of all four variables of interest (two physical doses and two LET values). However, this approach was not successful because of limitations in the response of the scanner.
引用
收藏
页码:709 / 726
页数:18
相关论文
共 26 条
[21]  
Schreiner L. J., 2004, Journal of Physics: Conference Series, V3, P9, DOI 10.1088/1742-6596/3/1/003
[22]   Temperature and temporal dependence of the optical response for a radiochromic dosimeter [J].
Skyt, Peter S. ;
Wahlstedt, Isak ;
Muren, Ludvig P. ;
Petersen, Jorgen B. B. ;
Balling, Peter .
MEDICAL PHYSICS, 2012, 39 (12) :7232-7236
[23]   Proton therapy [J].
Smith, Alfred R. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (13) :R491-R504
[24]  
Verhey L, 1998, 59 ICRU
[25]   Dosimetric evaluation of a novel polymer gel dosimeter for proton therapy [J].
Zeidan, O. A. ;
Sriprisan, S. I. ;
Lopatiuk-Tirpak, O. ;
Kupelian, P. A. ;
Meeks, S. L. ;
Hsi, W. C. ;
Li, Z. ;
Palta, J. R. ;
Maryanski, M. J. .
MEDICAL PHYSICS, 2010, 37 (05) :2145-2152
[26]   Feasibility of using PRESAGE® for relative 3D dosimetry of small proton fields [J].
Zhao, Li ;
Newton, Joseph ;
Oldham, Mark ;
Das, Indra J. ;
Cheng, Chee-Wai ;
Adamovics, John .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (22) :N431-N443