Issues involved in the quantitative 3D imaging of proton doses using optical CT and chemical dosimeters

被引:20
作者
Doran, Simon [1 ,2 ]
Gorjiara, Tina [3 ]
Kacperek, Andrzej [4 ]
Adamovics, John [5 ]
Kuncic, Zdenka [6 ]
Baldock, Clive [6 ]
机构
[1] CRUK Canc Imaging Ctr, Inst Canc Res, London, England
[2] Univ Surrey, Dept Phys, Guildford, Surrey, England
[3] Royal Prince Alfred Hosp, Camperdown, NSW 2050, Australia
[4] Clatterbridge Canc Ctr, Wirral, Merseyside, England
[5] Rider Univ, Dept Biol & Chem, Lawrenceville, NJ 08648 USA
[6] Univ Sydney, Sch Phys, Inst Med Phys, Sydney, NSW 2006, Australia
基金
英国工程与自然科学研究理事会;
关键词
optical CT; proton therapy; PRESAGE; POLYMER GEL DOSIMETER; DEPENDENCE; PRESAGE(R); APPARATUS; WATER; BEAMS;
D O I
10.1088/0031-9155/60/2/709
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dosimetry of proton beams using 3D imaging of chemical dosimeters is complicated by a variation with proton linear energy transfer (LET) of the dose-response (the so-called 'quenching effect'). Simple theoretical arguments lead to the conclusion that the total absorbed dose from multiple irradiations with different LETs cannot be uniquely determined from postirradiation imaging measurements on the dosimeter. Thus, a direct inversion of the imaging data is not possible and the proposition is made to use a forward model based on appropriate output from a planning system to predict the 3D response of the dosimeter. In addition to the quenching effect, it is well known that chemical dosimeters have a non-linear response at high doses. To the best of our knowledge it has not yet been determined how this phenomenon is affected by LET. The implications for dosimetry of a number of potential scenarios are examined. Dosimeter response as a function of depth (and hence LET) was measured for four samples of the radiochromic plastic PRESAGE (R), using an optical computed tomography readout and entrance doses of 2.0 Gy, 4.0 Gy, 7.8 Gy and 14.7 Gy, respectively. The dosimeter response was separated into two components, a single-exponential low-LET response and a LET-dependent quenching. For the particular formulation of PRESAGE (R) used, deviations from linearity of the dosimeter response became significant for doses above approximately 16 Gy. In a second experiment, three samples were each irradiated with two separate beams of 4 Gy in various different configurations. On the basis of the previous characterizations, two different models were tested for the calculation of the combined quenching effect from two contributions with different LETs. It was concluded that a linear superposition model with separate calculation of the quenching for each irradiation did not match the measured result where two beams overlapped. A second model, which used the concept of an 'effective dose' matched the experimental results more closely. An attempt was made to measure directly the quench function for two proton beams as a function of all four variables of interest (two physical doses and two LET values). However, this approach was not successful because of limitations in the response of the scanner.
引用
收藏
页码:709 / 726
页数:18
相关论文
共 26 条
[1]   Characterisation of PRESAGE™:: A new 3-D radiochromic solid polymer dosemeter for ionising radiation [J].
Adamovics, J. ;
Maryanski, M. J. .
RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) :107-112
[2]   A preliminary analysis of LET effects in the dosimetry of proton beams using PRESAGE™ and optical CT [J].
Al-Nowais, S. ;
Doran, S. ;
Kacperek, A. ;
Krstajic, N. ;
Adamovics, J. ;
Bradley, D. .
APPLIED RADIATION AND ISOTOPES, 2009, 67 (03) :415-418
[3]  
Al-Nowais S, 2010, J PHYS C SER, V250
[4]  
Bäck SÅJ, 1999, PHYS MED BIOL, V44, P1983, DOI 10.1088/0031-9155/44/8/310
[5]   Polymer gel dosimetry [J].
Baldock, C. ;
De Deene, Y. ;
Doran, S. ;
Ibbott, G. ;
Jirasek, A. ;
Lepage, M. ;
McAuley, K. B. ;
Oldham, M. ;
Schreiner, L. J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (05) :R1-R63
[6]   The fundamental radiation properties of normoxic polymer gel dosimeters: a comparison between a methacrylic acid based gel and acrylamide based gels [J].
De Deene, Y ;
Vergote, K ;
Claeys, C ;
De Wagter, C .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (03) :653-673
[7]  
Deluca P M, 2007, 78 ICRU
[8]   Water and tissue equivalence of a new PRESAGE® formulation for 3D proton beam dosimetry: A Monte Carlo study [J].
Gorjiara, Tina ;
Kuncic, Zdenka ;
Doran, Simon ;
Adamovics, John ;
Baldock, Clive .
MEDICAL PHYSICS, 2012, 39 (11) :7071-7079
[9]   Investigation of radiological properties and water equivalency of PRESAGE® dosimeters [J].
Gorjiara, Tina ;
Hill, Robin ;
Kuncic, Zdenka ;
Adamovics, John ;
Bosi, Stephen ;
Kim, Jung-Ha ;
Baldock, Clive .
MEDICAL PHYSICS, 2011, 38 (04) :2265-2274
[10]   Linear energy transfer dependence of a normoxic polymer gel dosimeter investigated using proton beam absorbed dose measurements [J].
Gustavsson, H ;
Bjäck, SAJ ;
Medin, J ;
Grusell, E ;
Olsson, LE .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (17) :3847-3855