RR interval variability in the evaluation of ventricular tachycardia and effects of implantable cardioverter defibrillator therapy

被引:3
|
作者
Tsukahara, Keita [1 ]
Oginosawa, Yasushi [1 ]
Fujino, Yoshihisa [2 ]
Honda, Toshihiro [3 ]
Kikuchi, Kan [4 ]
Nozoe, Masatsugu [5 ]
Uchida, Takayuki [6 ]
Minamiguchi, Hitoshi [7 ]
Sonoda, Koichiro [8 ]
Ogawa, Masahiro [9 ]
Ideguchi, Takeshi [10 ]
Kizaki, Yoshihisa [11 ]
Nakamura, Toshihiro [12 ]
Oba, Kageyuki [13 ]
Higa, Satoshi [14 ]
Yoshida, Keiki [15 ]
Yagyu, Keishiro [1 ]
Miyamoto, Taro [1 ]
Yamagishi, Yasunobu [1 ]
Ohe, Hisaharu [1 ]
Kohno, Ritsuko [16 ]
Kataoka, Masaharu [1 ]
Otsuji, Yutaka [1 ]
Abe, Haruhiko [16 ]
机构
[1] Univ Occupat & Environm Hlth, Dept Internal Med 2, Kitakyushu, Fukuoka, Japan
[2] Univ Occupat & Environm Hlth, Dept Environm Epidmiol, Inst Ind Ecol Sci, Kitakyushu, Fukuoka, Japan
[3] Kumamoto Junkankika Hosp, Div Cardiol, Kumamoto, Japan
[4] Kyushu Hosp, Div Cardiol, Japan Community Healthcare Org, Kitakyushu, Japan
[5] Saiseikai Fukuoka Gen Hosp, Div Cardiol, Fukuoka, Japan
[6] Iizuka Hosp, Dept Cardiovasc Surg, Iizuka, Japan
[7] Osaka Police Hosp, Dept Cardiol, Osaka, Japan
[8] Sasebo City Gen Hosp, Dept Cardiol, Sasebo, Japan
[9] Fukuoka Univ, Dept Cardiol, Sch Med, Fukuoka, Japan
[10] Univ Miyazaki, Fac Med, Dept Internal Med, Circulatory & Body Fluid Regulat, Miyazaki, Japan
[11] Sasebo Chuo Hosp, Dept Cardiol, Nagasaki, Japan
[12] Natl Hosp Org, Dept Cardiol, Kyushu Med Ctr, Fukuoka, Japan
[13] Yuai Med Ctr, Dept Cardiol, Okinawa, Japan
[14] Makiminato Cent Hosp, Div Cardiovasc Med, Cardiac Elctrophysiol & Pacing Lab, Okinawa, Japan
[15] Saga Ken Med Ctr Koseikan, Dept Cardiol, Saga, Saga, Japan
[16] Univ Occupat & Environm Hlth, Dept Heart Rhythm Management, Kitakyushu, Japan
关键词
anti-tachycardia pacing therapy; implantable cardioverter defibrillator; RR interval variability; shock therapy; ventricular tachycardia; ANTITACHYCARDIA PACING THERAPIES; REDUCTION; SHOCKS; TACHYARRHYTHMIAS;
D O I
10.1002/joa3.12551
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: An implantable cardioverter defibrillator (ICD) is the most reliable therapeutic device for preventing sudden cardiac death in patients with sustained ventricular tachycardia (VT). Regarding its effectiveness, targeted VT is defined based on the tachyarrhythmia cycle length. However, variations in RR interval variability of VTs may occur. Few studies have reported on VT characteristics and effects of ICD therapy according to the RR interval variability. We aimed to identify the clinical characteristics of VTs and ICD therapy effects according to the RR interval variability. Methods: We analyzed 821 VT episodes in 69 patients with ICDs or cardiac resynchronization therapy defibrillators. VTs were classified as irregular when the difference between two successive beats was >20 ms in at least one of 10 RR intervals; otherwise, they were classified as regular. We evaluated successful termination using anti-tachycardia pacing (ATP)/shock therapy, spontaneous termination, and acceleration between regular and irregular VTs. The RR interval variability reproducibility rates were evaluated. Results: Regular VT was significantly more successfully terminated than irregular VT by ATP. No significant difference was found in shock therapy or VT acceleration between the regular and irregular VTs. Spontaneous termination occurred significantly more often in irregular than in regular VT cases. The reproducibility rates of RR interval variability in each episode and in all episodes were 89% and 73%, respectively. Conclusions: ATP therapy showed greater effectiveness for regular than for irregular VT. Spontaneous termination was more common in irregular than in regular VT. RR interval variability of VTs seems to be reproducible.
引用
收藏
页码:1052 / 1060
页数:9
相关论文
共 50 条
  • [41] Both low and high energy cardioversion induced accelerated ventricular tachycardia in a patient treated with an implantable cardioverter defibrillator
    Washizuka, T
    Chinushi, M
    Hatada, K
    Kasai, H
    Ohhira, K
    Furushima, H
    Aizawa, Y
    JAPANESE HEART JOURNAL, 1999, 40 (05): : 665 - 669
  • [42] TREATMENT OF VENTRICULAR-TACHYCARDIA AND FIBRILLATION WITH LOW-ENERGY CARDIOVERSION BY THE IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR (ICD)
    SIEBELS, J
    SCHNEIDER, MAE
    KUCK, KH
    ZEITSCHRIFT FUR KARDIOLOGIE, 1993, 82 (11): : 683 - 691
  • [43] Adjunctive therapy for recurrent ventricular tachycardia in patients with implantable cardioverter defibrillators
    Reiffel J.A.
    Current Cardiology Reports, 2007, 9 (5) : 381 - 386
  • [44] Safety and efficacy of a dual chamber implantable cardioverter defibrillator capable of slow ventricular tachycardia discrimination:: A randomized study
    Mletzko, R
    Aliot, E
    Seidl, K
    Lavergne, T
    Mabo, P
    Hohnloser, S
    Böcker, D
    Schoels, W
    Sadoul, N
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (12): : 2275 - 2282
  • [45] Does Volume Overload Predict Failed Antitachycardia Pacing Therapy for Ventricular Tachycardia in Patients With an Implantable Cardioverter-Defibrillator?
    Hosseini-khalili, Alireza
    Kluger, Jeffrey
    CIRCULATION, 2014, 130
  • [46] Implantable cardioverter defibrillator events in patients with asymptomatic nonsustained ventricular tachycardia: Is device implantation justified?
    Russo, AM
    Nayak, H
    Verdino, R
    Springman, J
    Gerstenfeld, E
    Hsia, H
    Marchlinski, FE
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (12): : 2289 - 2295
  • [47] Incidence and predictors of mortality following ablation of ventricular tachycardia in patients with an implantable cardioverter-defibrillator
    Sauer, William H.
    Zado, Erica
    Gerstenfeld, Edward P.
    Marchlinski, Francis E.
    Callans, David J.
    HEART RHYTHM, 2010, 7 (01) : 9 - 14
  • [48] Underdetection of ventricular tachycardia by an implantable cardioverter–defibrillator due to a locally prolonged arrhythmia cycle length
    Illkyu-Oliver Lee
    Christian Ukena
    Michael Böhm
    Axel Buob
    Hans-Ruprecht Neuberger
    Clinical Research in Cardiology, 2013, 102 : 923 - 925
  • [49] Predictors and Proarrhythmic Consequences of Inappropriate Implantable Cardioverter-Defibrillator Therapy
    Tenma, Taro
    Yokoshiki, Hisashi
    Mizukami, Kazuya
    Mitsuyama, Hirofumi
    Watanabe, Masaya
    Sasaki, Ryo
    Maeno, Motoki
    Matsui, Yoshiro
    Tsutsui, Hiroyuki
    CIRCULATION JOURNAL, 2015, 79 (09) : 1920 - U242
  • [50] Induction of ventricular fibrillation rather than ventricular tachycardia predicts tachyarrhythmia recurrences in patients with idiopathic dilated cardiomyopathy and implantable cardioverter defibrillator for secondary prophylaxis
    Rolf, Sascha
    Haverkamp, Wilhelm
    Borggrefe, Martin
    Breithardt, Guenter
    Bocker, Dirk
    EUROPACE, 2009, 11 (03): : 289 - 296