An experimental study on reinforced concrete beams strengthened with prestressed near surface mounted CFRP strips

被引:94
作者
Peng, Hui [1 ,2 ]
Zhang, Jianren [3 ]
Cai, C. S. [4 ]
Liu, Yang [3 ]
机构
[1] Changsha Univ Sci & Technol, Minist Educ, Key Lab Safety Control Bridge Engn, Changsha 410004, Hunan, Peoples R China
[2] Louisiana State Univ, Baton Rouge, LA 70803 USA
[3] Changsha Univ Sci & Technol, Sch Civil Engn & Architecture, Minist Educ, Key Lab Safety Control Bridge Engn, Changsha 410004, Hunan, Peoples R China
[4] Louisiana State Univ, Dept Civil & Environm Engn, Baton Rouge, LA 70803 USA
基金
中国国家自然科学基金;
关键词
Near surface mounted; Prestressed; FRP strips; Strengthening; Failure mode; RC BEAMS; FRP REINFORCEMENT; T-BEAMS; CAPACITY; PERFORMANCE; SHEAR; SLABS; RODS; BOND;
D O I
10.1016/j.engstruct.2014.08.007
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Externally-bonded prestressed FRP plates and near surface mounted (NSM) FRP strips are two important techniques of strengthening concrete structures with FRP materials. However, there are considerable limitations for these two techniques. Using prestressed NSM FRP strips can combine the advantages of these two strengthening methods and it thus becomes very attractive to further promote FRP applications in retrofitting concrete structures. In this paper, a total of 7 rectangular reinforced concrete beams were constructed for static load tests, of which 1 specimen was the reference beam and the other 6 beams were strengthened with FRP strips. The behavior and failure modes of these specimens were investigated, the difference of the mechanical performance due to various strengthening techniques was compared, and the effect of parameters, such as the bond length, prestressing force, and the anchorage, on the behavior and failure modes of specimens was analyzed. The testing results showed that the load-carrying behavior of flexural members could be improved significantly by strengthening with prestressed NSM FRP strips, since the highest load-carrying capacity of the beam with prestressed NSM strips is increased by 122% and 44.2% when compared to the beam without strengthening and with non-prestressed FRP strips, respectively. While the prestressed FRP strips could be anchored by epoxy through the near surface mounting, the failure modes of beams strengthened with this technique might be the debonding of epoxy- concrete interface and delamination of the concrete cover. It was proven that these failure modes can be avoided by extending the bond length of FRP strips or using U-wraps of CFRP sheets. The stress transfer length of the prestressed-FRP strengthened beam with U-wrap anchorage is approximately 100 mm. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:222 / 233
页数:12
相关论文
共 28 条
[1]   Anchorage and tension-stiffening effect between near-surface-mounted CFRP rods and concrete [J].
Al-Mahmoud, Firas ;
Castel, Arnaud ;
Francois, Raoul ;
Tourneur, Christian .
CEMENT & CONCRETE COMPOSITES, 2011, 33 (02) :346-352
[2]  
[Anonymous], 2005, 318R05 ACI
[3]  
[Anonymous], 2007, LRFD BRIDG DES SPEC, V4th
[4]  
Badawi M., 2007, THESIS U WATERLOO WA
[5]   Evaluation of the transfer length of prestressed near surface mounted CFRP rods in concrete [J].
Badawi, Moataz ;
Wahab, Noran ;
Soudki, Khaled .
CONSTRUCTION AND BUILDING MATERIALS, 2011, 25 (03) :1474-1479
[6]   Flexural strengthening of RC beams with prestressed NSM CFRP rods - Experimental and analytical investigation [J].
Badawi, Moataz ;
Soudki, Khaled .
CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (10) :3292-3300
[7]   Effect of Partial Unbonding on Prestressed Near-Surface-Mounted CFRP-Strengthened Concrete T-Beams [J].
Choi, Han T. ;
West, Jeffrey S. ;
Soudki, Khaled A. .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2011, 15 (01) :93-102
[8]   Flexural and shear strengthening of RC beams with composite materials - The influence of cutting steel stirrups to install CFRP strips [J].
Costa, Ines G. ;
Barros, Joaquim A. O. .
CEMENT & CONCRETE COMPOSITES, 2010, 32 (07) :544-553
[9]   NSM technique to increase the load carrying capacity of continuous RC slabs [J].
Dalfre, Glaucia M. ;
Barros, Joaquim A. O. .
ENGINEERING STRUCTURES, 2013, 56 :137-153
[10]   A modified pull-out test for bond of near-surface mounted FRP rods in concrete [J].
De Lorenzis, L ;
Rizzo, A ;
La Tegola, A .
COMPOSITES PART B-ENGINEERING, 2002, 33 (08) :589-603