Application of Artificial Intelligence-based Image Optimization for Computed Tomography Angiography of the Aorta With Low Tube Voltage and Reduced Contrast Medium Volume

被引:13
作者
Wang, Yining [1 ]
Yu, Min [2 ]
Wang, Ming [1 ]
Wang, Yun [1 ]
Kong, Lingyan [1 ]
Yi, Yan [1 ]
Wang, Man [1 ]
Li, Yumei [1 ]
Jin, Zhengyu [1 ]
机构
[1] Peking Union Med Coll Hosp, Dept Radiol, Beijing, Peoples R China
[2] Neusoft Med Syst Co, CT Business Unit, Shenyang, Liaoning, Peoples R China
基金
中国国家自然科学基金;
关键词
artificial intelligence; computed tomography angiography; image quality; tube voltage; contrast medium; image noise; noise reduction; ITERATIVE RECONSTRUCTION; CT ANGIOGRAPHY; RADIATION-EXPOSURE; QUALITY;
D O I
10.1097/RTI.0000000000000438
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to evaluate the impact of artificial intelligence (AI)-based noise reduction algorithm on aorta computed tomography angiography (CTA) image quality (IQ) at 80 kVp tube voltage and 40 mL contrast medium (CM). Materials and Methods: After obtaining institutional review board approval and 8 written informed consents, 60 patients (35 men, 25 women; age range: 18 to 85 y) referred for aorta CTA examination were assigned to 2 groups at random. Group A underwent an 80 kVp protocol with 40 mL CM (320 mg I/mL). Group A reconstructed with iterative reconstruction was named as group A1 and further AI-based noise reduction was named as group A2. Group B was scanned with standard 120 kVp, 80 mL CM, and iterative reconstruction algorithm. The quantitative assessment of IQ included aorta CT attenuation, noise, signal-to-noise ratio, and contrast-to-noise ratio. A 5-point scale (5-excellent, 1-poor) was used by 2 radiologists independently for qualitative IQ analysis. Results: The image noise significantly decreased while signal-to-noise ratio and contrast-to-noise ratio significantly increased in the order of group A1, B, and A2 (all P<0.05). Compared with group B, the subjective IQ score of group A1 was significantly lower (P<0.05), while that of group A2 had no significant difference (P>0.05). The effective dose and CM volume of group A were reduced by 79.18% and 50%, respectively, than that of group B. Conclusions: The AI-based noise reduction could improve the IQ of aorta CTA with low kV and reduced CM, which achieved the potential of radiation dose and contrast media reduction compared with conventional aorta CTA protocol.
引用
收藏
页码:393 / 399
页数:7
相关论文
共 48 条
[31]   Improved Image Quality and Decreased Radiation Dose of Lower Extremity Computed Tomography Angiography Using Low-Tube-Voltage and Adaptive Iterative Reconstruction [J].
Pan, Yu-Ning ;
Li, Ai-Jing ;
Chen, Zhao-Qian ;
Ren, Da-Wei ;
Zhang, Jie ;
Jiang, Mao-Qing ;
Huang, Qiu-Li .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (02) :272-276
[32]   Application value of individualized tube voltage, contrast injection, and adaptive statistical iterative reconstruction V algorithm based on body mass index in renal computed tomography angiography for radiation and iodinated contrast dose reduction [J].
Li, Junjun ;
Xiao, Yi ;
Cao, Le ;
Cheng, Yannan ;
Li, Yanan ;
Jia, Xiaoqian ;
Li, Xinyu ;
Fan, Ganglian ;
Li, Jianying ;
Guo, Jianxin .
BRITISH JOURNAL OF RADIOLOGY, 2024, 97 (1164) :1971-1978
[33]   Novel artificial intelligence-based hypodensity detection tool improves clinician identification of hypodensity on non-contrast computed tomography in stroke patients [J].
Dos Santos, Angela ;
Visser, Milanka ;
Lin, Longting ;
Bivard, Andrew ;
Churilov, Leonid ;
Parsons, Mark William .
FRONTIERS IN NEUROLOGY, 2024, 15
[34]   Evaluation of Low-dose Computed Tomography Images Reconstructed Using Artificial Intelligence-based Adaptive Filtering for Denoising: A Comparison with Computed Tomography Reconstructed with Iterative Reconstruction Algorithm [J].
Kulkarni, Suyash ;
Patil, Vasundhara ;
Nene, Aniruddha ;
Shetty, Nitin ;
Choudhari, Amitkumar ;
Joshi, Akansha ;
Pramesh, C. S. ;
Baheti, Akshay ;
Mahadik, Kalpesh .
JOURNAL OF MEDICAL PHYSICS, 2025, 50 (01) :108-117
[35]   Low contrast medium-volume third-generation dual-source computed tomography angiography for transcatheter aortic valve replacement planning [J].
Felmly, Lloyd M. ;
De Cecco, Carlo N. ;
Schoepf, U. Joseph ;
Varga-Szemes, Akos ;
Mangold, Stefanie ;
McQuiston, Andrew D. ;
Litwin, Sheldon E. ;
Bayer, Richard R., II ;
Vogl, Thomas J. ;
Wichmann, Julian L. .
EUROPEAN RADIOLOGY, 2017, 27 (05) :1944-1953
[36]   Low contrast medium-volume third-generation dual-source computed tomography angiography for transcatheter aortic valve replacement planning [J].
Lloyd M. Felmly ;
Carlo N. De Cecco ;
U. Joseph Schoepf ;
Akos Varga-Szemes ;
Stefanie Mangold ;
Andrew D. McQuiston ;
Sheldon E. Litwin ;
Richard R. Bayer ;
Thomas J. Vogl ;
Julian L. Wichmann .
European Radiology, 2017, 27 :1944-1953
[37]   Low Radiation Dose and High Image Quality of 320-Row Coronary Computed Tomography Angiography Using a Small Dose of Contrast Medium and Refined Scan Timing Prediction [J].
Shirasaka, Takashi ;
Nagao, Michinobu ;
Yamasaki, Yuzo ;
Kojima, Tsukasa ;
Kondo, Masatoshi ;
Hamasaki, Hiroshi ;
Kamitani, Takeshi ;
Kato, Toyoyuki ;
Asayama, Yoshiki .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (01) :7-12
[38]   Effect of reduced x-ray tube voltage, low iodine concentration contrast medium, and sinogram-affirmed iterative reconstruction on image quality and radiation dose at coronary CT angiography: Results of the prospective multicenter REALISE trial [J].
Yin, Wei-Hua ;
Lu, Bin ;
Gao, Jian-Bo ;
Li, Pei-Ling ;
Sun, Kai ;
Wu, Zhi-Feng ;
Yang, Wen-Jie ;
Zhang, Xiao-Qin ;
Zheng, Min-Wen ;
McQuiston, Andrew D. ;
Meinel, Felix G. ;
Schoepf, Uwe Joseph .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2015, 9 (03) :215-224
[39]   Preliminary phantom study of four-dimensional computed tomographic angiography for renal artery mapping: Low-tube voltage and low-contrast volume imaging with deep learning-based reconstruction [J].
Urikura, A. ;
Ishii, I. ;
Sone, M. ;
Sugawara, S. ;
Itou, C. ;
Kimura, S. ;
Suzuki, H. ;
Ishihara, T. ;
Kusumoto, M. .
RADIOGRAPHY, 2025, 31 (03)
[40]   Reducing Iodine Contrast Volume in CT Angiography of the Abdominal Aorta Using Integrated Tube Potential Selection and Weight-Based Method Without Compromising Image Quality [J].
Vasconcelos, Rogerio ;
Vrtiska, Terri J. ;
Foley, Thomas A. ;
Macedo, Thanila A. ;
Cardona, Juan C. Montoya ;
Williamson, Eric E. ;
McCollough, Cynthia H. ;
Fletcher, Joel G. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 208 (03) :552-563