Application of Artificial Intelligence-based Image Optimization for Computed Tomography Angiography of the Aorta With Low Tube Voltage and Reduced Contrast Medium Volume

被引:11
作者
Wang, Yining [1 ]
Yu, Min [2 ]
Wang, Ming [1 ]
Wang, Yun [1 ]
Kong, Lingyan [1 ]
Yi, Yan [1 ]
Wang, Man [1 ]
Li, Yumei [1 ]
Jin, Zhengyu [1 ]
机构
[1] Peking Union Med Coll Hosp, Dept Radiol, Beijing, Peoples R China
[2] Neusoft Med Syst Co, CT Business Unit, Shenyang, Liaoning, Peoples R China
基金
中国国家自然科学基金;
关键词
artificial intelligence; computed tomography angiography; image quality; tube voltage; contrast medium; image noise; noise reduction; ITERATIVE RECONSTRUCTION; CT ANGIOGRAPHY; RADIATION-EXPOSURE; QUALITY;
D O I
10.1097/RTI.0000000000000438
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to evaluate the impact of artificial intelligence (AI)-based noise reduction algorithm on aorta computed tomography angiography (CTA) image quality (IQ) at 80 kVp tube voltage and 40 mL contrast medium (CM). Materials and Methods: After obtaining institutional review board approval and 8 written informed consents, 60 patients (35 men, 25 women; age range: 18 to 85 y) referred for aorta CTA examination were assigned to 2 groups at random. Group A underwent an 80 kVp protocol with 40 mL CM (320 mg I/mL). Group A reconstructed with iterative reconstruction was named as group A1 and further AI-based noise reduction was named as group A2. Group B was scanned with standard 120 kVp, 80 mL CM, and iterative reconstruction algorithm. The quantitative assessment of IQ included aorta CT attenuation, noise, signal-to-noise ratio, and contrast-to-noise ratio. A 5-point scale (5-excellent, 1-poor) was used by 2 radiologists independently for qualitative IQ analysis. Results: The image noise significantly decreased while signal-to-noise ratio and contrast-to-noise ratio significantly increased in the order of group A1, B, and A2 (all P<0.05). Compared with group B, the subjective IQ score of group A1 was significantly lower (P<0.05), while that of group A2 had no significant difference (P>0.05). The effective dose and CM volume of group A were reduced by 79.18% and 50%, respectively, than that of group B. Conclusions: The AI-based noise reduction could improve the IQ of aorta CTA with low kV and reduced CM, which achieved the potential of radiation dose and contrast media reduction compared with conventional aorta CTA protocol.
引用
收藏
页码:393 / 399
页数:7
相关论文
共 50 条
[21]   Cerebral Computed Tomography Angiography Using a Low Tube Voltage (80 kVp) and a Moderate Concentration of Iodine Contrast Material A Quantitative and Qualitative Comparison With Conventional Computed Tomography Angiography [J].
Cho, Eun-Suk ;
Chung, Tae-Sub ;
Oh, Dae Kun ;
Choi, Hyun Seok ;
Suh, Sang Hyun ;
Lee, Hyeon-Kyeong ;
Lee, Kyung Hee .
INVESTIGATIVE RADIOLOGY, 2012, 47 (02) :142-147
[22]   Artificial Intelligence-based quantification of atherosclerotic plaque and stenosis from coronary computed tomography angiography using a novel method [J].
Lin, Andrew ;
Manral, Nipun ;
McElhinney, Priscilla ;
Killekar, Aditya ;
Matsumoto, Hidenari ;
Kwiecinski, Jacek ;
Pieszko, Konrad ;
Razipour, Aryabod ;
Grodecki, Kajetan ;
Park, Caroline ;
Doris, Mhairi ;
Kwan, Alan C. ;
Han, Donghee ;
Kuronama, Keiichiro ;
Tomasino, Guadalupe Flores ;
Tzolos, Evangelos ;
Shanbhag, Aakash ;
Goeller, Markus ;
Marwan, Mohamed ;
Cadet, Sebastien ;
Achenbach, Stephan ;
Nicholls, Stephen J. ;
Wong, Dennis T. ;
Berman, Daniel S. ;
Dweck, Marc ;
Newby, David E. ;
Williams, Michelle C. ;
Slomka, Piotr J. ;
Dey, Damini .
MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
[23]   Artificial intelligence-based opportunistic detection of coronary artery stenosis on aortic computed tomography angiography in emergency department patients with acute chest pain [J].
Glessgen, Carl G. ;
Boulougouri, Marianthi ;
Vallee, Jean-Paul ;
Noble, Stephane ;
Platon, Alexandra ;
Poletti, Pierre-Alexandre ;
Paul, Jean-Francois ;
Deux, Jean-Francois .
EUROPEAN HEART JOURNAL OPEN, 2023, 3 (05)
[24]   A review of computed tomography pulmonary angiogram protocols with low contrast medium volume in delivering diagnostic image quality [J].
Konstantinidis, K. .
ARCHIVES OF HELLENIC MEDICINE, 2025, 42 (04) :457-462
[25]   Evaluation of an iterative model-based reconstruction algorithm for low-tube-voltage (80 kVp) computed tomography angiography [J].
Noel, Peter B. ;
Koehler, Thomas ;
Fingerle, Alexander A. ;
Brown, Kevin M. ;
Zabic, Stanislav ;
Muenzel, Daniela ;
Haller, Bernhard ;
Baum, Thomas ;
Henninger, Martin ;
Meier, Reinhard ;
Rummeny, Ernst J. ;
Dobritz, Martin .
JOURNAL OF MEDICAL IMAGING, 2014, 1 (03)
[26]   Prognostic value of a novel artificial intelligence-based coronary computed tomography angiography-derived ischaemia algorithm for patients with suspected coronary artery disease [J].
Bar, Sarah ;
Nabeta, Takeru ;
Maaniitty, Teemu ;
Saraste, Antti ;
Bax, Jeroen J. ;
Earls, James P. ;
Min, James K. ;
Knuuti, Juhani .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2024, 25 (05) :657-667
[27]   Cerebral computed tomography angiography using a 70 kVp protocol: improved vascular enhancement with a reduced volume of contrast medium and radiation dose [J].
Eun-Suk Cho ;
Tae-Sub Chung ;
Sung Jun Ahn ;
KyoungHoon Chong ;
Jang Hun Baek ;
Sang Hyun Suh .
European Radiology, 2015, 25 :1421-1430
[28]   Evaluation of Deep Vein Thrombosis With Reduced Radiation and Contrast Material Dose at Computed Tomography Venography - Clinical Application of a Combined Iterative Reconstruction and Low-Tube-Voltage Technique [J].
Oda, Seitaro ;
Utsunomiya, Daisuke ;
Funama, Yoshinori ;
Shimonobo, Toshiaki ;
Namimoto, Tomohiro ;
Itatani, Ryo ;
Hirai, Toshinori ;
Yamashita, Yasuyuki .
CIRCULATION JOURNAL, 2012, 76 (11) :2614-2622
[29]   Evaluation of a Tube Voltage-Based Contrast Media Adaptation in Coronary Computed Tomography Angiography Using Personalized Triphasic Injection Protocols: A Matched Case-Control Study [J].
Gnasso, Chiara ;
Vecsey-Nagy, Milan ;
Schoepf, U. Joseph ;
Stock, Jonathan ;
Zsarnoczay, Emese ;
Pinos, Daniel ;
Tremamunno, Giuseppe ;
Giovagnoli, Vincent ;
Seidensticker, Peter ;
Emrich, Tilman ;
Varga-Szemes, Akos .
ACADEMIC RADIOLOGY, 2024, 31 (09) :3570-3578
[30]   Artificial intelligence-based image-domain material decomposition in single-energy computed tomography for head and neck cancer [J].
Yuhei Koike ;
Shingo Ohira ;
Yuki Yamamoto ;
Masayoshi Miyazaki ;
Koji Konishi ;
Satoaki Nakamura ;
Noboru Tanigawa .
International Journal of Computer Assisted Radiology and Surgery, 2024, 19 :541-551