Application of Artificial Intelligence-based Image Optimization for Computed Tomography Angiography of the Aorta With Low Tube Voltage and Reduced Contrast Medium Volume

被引:12
作者
Wang, Yining [1 ]
Yu, Min [2 ]
Wang, Ming [1 ]
Wang, Yun [1 ]
Kong, Lingyan [1 ]
Yi, Yan [1 ]
Wang, Man [1 ]
Li, Yumei [1 ]
Jin, Zhengyu [1 ]
机构
[1] Peking Union Med Coll Hosp, Dept Radiol, Beijing, Peoples R China
[2] Neusoft Med Syst Co, CT Business Unit, Shenyang, Liaoning, Peoples R China
基金
中国国家自然科学基金;
关键词
artificial intelligence; computed tomography angiography; image quality; tube voltage; contrast medium; image noise; noise reduction; ITERATIVE RECONSTRUCTION; CT ANGIOGRAPHY; RADIATION-EXPOSURE; QUALITY;
D O I
10.1097/RTI.0000000000000438
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to evaluate the impact of artificial intelligence (AI)-based noise reduction algorithm on aorta computed tomography angiography (CTA) image quality (IQ) at 80 kVp tube voltage and 40 mL contrast medium (CM). Materials and Methods: After obtaining institutional review board approval and 8 written informed consents, 60 patients (35 men, 25 women; age range: 18 to 85 y) referred for aorta CTA examination were assigned to 2 groups at random. Group A underwent an 80 kVp protocol with 40 mL CM (320 mg I/mL). Group A reconstructed with iterative reconstruction was named as group A1 and further AI-based noise reduction was named as group A2. Group B was scanned with standard 120 kVp, 80 mL CM, and iterative reconstruction algorithm. The quantitative assessment of IQ included aorta CT attenuation, noise, signal-to-noise ratio, and contrast-to-noise ratio. A 5-point scale (5-excellent, 1-poor) was used by 2 radiologists independently for qualitative IQ analysis. Results: The image noise significantly decreased while signal-to-noise ratio and contrast-to-noise ratio significantly increased in the order of group A1, B, and A2 (all P<0.05). Compared with group B, the subjective IQ score of group A1 was significantly lower (P<0.05), while that of group A2 had no significant difference (P>0.05). The effective dose and CM volume of group A were reduced by 79.18% and 50%, respectively, than that of group B. Conclusions: The AI-based noise reduction could improve the IQ of aorta CTA with low kV and reduced CM, which achieved the potential of radiation dose and contrast media reduction compared with conventional aorta CTA protocol.
引用
收藏
页码:393 / 399
页数:7
相关论文
共 48 条
  • [21] Cerebral Computed Tomography Angiography Using a Low Tube Voltage (80 kVp) and a Moderate Concentration of Iodine Contrast Material A Quantitative and Qualitative Comparison With Conventional Computed Tomography Angiography
    Cho, Eun-Suk
    Chung, Tae-Sub
    Oh, Dae Kun
    Choi, Hyun Seok
    Suh, Sang Hyun
    Lee, Hyeon-Kyeong
    Lee, Kyung Hee
    INVESTIGATIVE RADIOLOGY, 2012, 47 (02) : 142 - 147
  • [22] Artificial Intelligence-based quantification of atherosclerotic plaque and stenosis from coronary computed tomography angiography using a novel method
    Lin, Andrew
    Manral, Nipun
    McElhinney, Priscilla
    Killekar, Aditya
    Matsumoto, Hidenari
    Kwiecinski, Jacek
    Pieszko, Konrad
    Razipour, Aryabod
    Grodecki, Kajetan
    Park, Caroline
    Doris, Mhairi
    Kwan, Alan C.
    Han, Donghee
    Kuronama, Keiichiro
    Tomasino, Guadalupe Flores
    Tzolos, Evangelos
    Shanbhag, Aakash
    Goeller, Markus
    Marwan, Mohamed
    Cadet, Sebastien
    Achenbach, Stephan
    Nicholls, Stephen J.
    Wong, Dennis T.
    Berman, Daniel S.
    Dweck, Marc
    Newby, David E.
    Williams, Michelle C.
    Slomka, Piotr J.
    Dey, Damini
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [23] Artificial intelligence-based image-domain material decomposition in single-energy computed tomography for head and neck cancer
    Koike, Yuhei
    Ohira, Shingo
    Yamamoto, Yuki
    Miyazaki, Masayoshi
    Konishi, Koji
    Nakamura, Satoaki
    Tanigawa, Noboru
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2024, 19 (03) : 541 - 551
  • [24] Evaluation of an iterative model-based reconstruction algorithm for low-tube-voltage (80 kVp) computed tomography angiography
    Noel, Peter B.
    Koehler, Thomas
    Fingerle, Alexander A.
    Brown, Kevin M.
    Zabic, Stanislav
    Muenzel, Daniela
    Haller, Bernhard
    Baum, Thomas
    Henninger, Martin
    Meier, Reinhard
    Rummeny, Ernst J.
    Dobritz, Martin
    JOURNAL OF MEDICAL IMAGING, 2014, 1 (03)
  • [25] Prognostic value of a novel artificial intelligence-based coronary computed tomography angiography-derived ischaemia algorithm for patients with suspected coronary artery disease
    Bar, Sarah
    Nabeta, Takeru
    Maaniitty, Teemu
    Saraste, Antti
    Bax, Jeroen J.
    Earls, James P.
    Min, James K.
    Knuuti, Juhani
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2024, 25 (05) : 657 - 667
  • [26] Cerebral computed tomography angiography using a 70 kVp protocol: improved vascular enhancement with a reduced volume of contrast medium and radiation dose
    Eun-Suk Cho
    Tae-Sub Chung
    Sung Jun Ahn
    KyoungHoon Chong
    Jang Hun Baek
    Sang Hyun Suh
    European Radiology, 2015, 25 : 1421 - 1430
  • [27] Evaluation of Deep Vein Thrombosis With Reduced Radiation and Contrast Material Dose at Computed Tomography Venography - Clinical Application of a Combined Iterative Reconstruction and Low-Tube-Voltage Technique
    Oda, Seitaro
    Utsunomiya, Daisuke
    Funama, Yoshinori
    Shimonobo, Toshiaki
    Namimoto, Tomohiro
    Itatani, Ryo
    Hirai, Toshinori
    Yamashita, Yasuyuki
    CIRCULATION JOURNAL, 2012, 76 (11) : 2614 - 2622
  • [28] Artificial intelligence-based image-domain material decomposition in single-energy computed tomography for head and neck cancer
    Yuhei Koike
    Shingo Ohira
    Yuki Yamamoto
    Masayoshi Miyazaki
    Koji Konishi
    Satoaki Nakamura
    Noboru Tanigawa
    International Journal of Computer Assisted Radiology and Surgery, 2024, 19 : 541 - 551
  • [29] Evaluation of a Tube Voltage-Based Contrast Media Adaptation in Coronary Computed Tomography Angiography Using Personalized Triphasic Injection Protocols: A Matched Case-Control Study
    Gnasso, Chiara
    Vecsey-Nagy, Milan
    Schoepf, U. Joseph
    Stock, Jonathan
    Zsarnoczay, Emese
    Pinos, Daniel
    Tremamunno, Giuseppe
    Giovagnoli, Vincent
    Seidensticker, Peter
    Emrich, Tilman
    Varga-Szemes, Akos
    ACADEMIC RADIOLOGY, 2024, 31 (09) : 3570 - 3578
  • [30] Computed Tomography (CT) Venography With Dual-Energy CT: Low Tube Voltage and Dose Reduction of Contrast Medium for Detection of Deep Vein Thrombosis
    Ichikawa, Shintaro
    Ichikawa, Tomoaki
    Motosugi, Utaroh
    Imaizumi, Akira
    Sano, Katsuhiro
    Morisaka, Hiroyuki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (05) : 797 - 801