Application of Artificial Intelligence-based Image Optimization for Computed Tomography Angiography of the Aorta With Low Tube Voltage and Reduced Contrast Medium Volume

被引:12
|
作者
Wang, Yining [1 ]
Yu, Min [2 ]
Wang, Ming [1 ]
Wang, Yun [1 ]
Kong, Lingyan [1 ]
Yi, Yan [1 ]
Wang, Man [1 ]
Li, Yumei [1 ]
Jin, Zhengyu [1 ]
机构
[1] Peking Union Med Coll Hosp, Dept Radiol, Beijing, Peoples R China
[2] Neusoft Med Syst Co, CT Business Unit, Shenyang, Liaoning, Peoples R China
基金
中国国家自然科学基金;
关键词
artificial intelligence; computed tomography angiography; image quality; tube voltage; contrast medium; image noise; noise reduction; ITERATIVE RECONSTRUCTION; CT ANGIOGRAPHY; RADIATION-EXPOSURE; QUALITY;
D O I
10.1097/RTI.0000000000000438
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to evaluate the impact of artificial intelligence (AI)-based noise reduction algorithm on aorta computed tomography angiography (CTA) image quality (IQ) at 80 kVp tube voltage and 40 mL contrast medium (CM). Materials and Methods: After obtaining institutional review board approval and 8 written informed consents, 60 patients (35 men, 25 women; age range: 18 to 85 y) referred for aorta CTA examination were assigned to 2 groups at random. Group A underwent an 80 kVp protocol with 40 mL CM (320 mg I/mL). Group A reconstructed with iterative reconstruction was named as group A1 and further AI-based noise reduction was named as group A2. Group B was scanned with standard 120 kVp, 80 mL CM, and iterative reconstruction algorithm. The quantitative assessment of IQ included aorta CT attenuation, noise, signal-to-noise ratio, and contrast-to-noise ratio. A 5-point scale (5-excellent, 1-poor) was used by 2 radiologists independently for qualitative IQ analysis. Results: The image noise significantly decreased while signal-to-noise ratio and contrast-to-noise ratio significantly increased in the order of group A1, B, and A2 (all P<0.05). Compared with group B, the subjective IQ score of group A1 was significantly lower (P<0.05), while that of group A2 had no significant difference (P>0.05). The effective dose and CM volume of group A were reduced by 79.18% and 50%, respectively, than that of group B. Conclusions: The AI-based noise reduction could improve the IQ of aorta CTA with low kV and reduced CM, which achieved the potential of radiation dose and contrast media reduction compared with conventional aorta CTA protocol.
引用
收藏
页码:393 / 399
页数:7
相关论文
共 47 条
  • [11] Diagnostic accuracy of low-radiation coronary computed tomography angiography with low tube voltage and knowledge-based model reconstruction
    Lee, Joohee
    Kim, Tae Hoon
    Lee, Byoung Kwon
    Yoon, Young Won
    Kwon, Hyuck Moon
    Hong, Bum Kee
    Min, Pil-Ki
    Choi, Eui-Young
    Oh, Chi Suk
    Park, Chul Hwan
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [12] Application of a Deep Learning-Based Contrast-Boosting Algorithm to Low-Dose Computed Tomography Pulmonary Angiography With Reduced Iodine Load
    Park, Minsu
    Hwang, Minhee
    Lee, Ji Won
    Kim, Kun-Il
    Ahn, Chulkyun
    Suh, Young Ju
    Jeong, Yeon Joo
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2025, 49 (02) : 288 - 296
  • [13] Radiation dose reduction at low tube voltage with coronary artery bypass graft computed tomography angiography based on the contrast noise ratio index
    Masuda, Takanori
    Nakaura, Takeshi
    Funama, Yoshinori
    Sato, Tomoyasu
    Masuda, Shouko
    Gotanda, Rumi
    Arao, Keiko
    Imaizumi, Hiromasa
    Arao, Shinichi
    Ono, Atsushi
    Hiratsuka, Junichi
    Awai, Kazuo
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (06) : 527 - 532
  • [14] Influence of contrast agent on artificial intelligence-based CT low attenuation volume percentage measurement
    Wiedbrauck, Damian
    Karczewski, Maciej
    Schoenberg, Stefan O.
    Fink, Christian
    Kayed, Hany
    ACTA RADIOLOGICA, 2023, 64 (06) : 2111 - 2117
  • [15] Application of low-concentration contrast agents and low-tube-voltage computed tomography to chest enhancement examinations: A multicenter prospective study
    Meng, Donghua
    Cui, Xiaonan
    Bai, Changsen
    Yu, Zhongwen
    Xin, Lei
    Fu, Yufei
    Wang, Sicong
    Du, Yu
    Gao, Zhipeng
    Ye, Zhaoxiang
    SCIENCE PROGRESS, 2020, 103 (01)
  • [16] Low-iodine-dose computed tomography coupled with an artificial intelligence-based contrast-boosting technique in children: a retrospective study on comparison with conventional-iodine-dose computed tomography
    Shin, Dong-Joo
    Choi, Young Hun
    Lee, Seul Bi
    Cho, Yeon Jin
    Lee, Seunghyun
    Cheon, Jung-Eun
    PEDIATRIC RADIOLOGY, 2024, 54 (08) : 1315 - 1324
  • [17] Comparing feasibility of low-tube-voltage protocol with low-iodine-concentration contrast and high-tube-voltage protocol with high-iodine-concentration contrast in coronary computed tomography angiography
    Cha, Min Jae
    Kim, Sung Mok
    Ahn, Tae Ran
    Choe, Yeon Hyeon
    PLOS ONE, 2020, 15 (07):
  • [18] Cerebral computed tomography angiography using a 70 kVp protocol: improved vascular enhancement with a reduced volume of contrast medium and radiation dose
    Cho, Eun-Suk
    Chung, Tae-Sub
    Ahn, Sung Jun
    Chong, KyoungHoon
    Baek, Jang Hun
    Suh, Sang Hyun
    EUROPEAN RADIOLOGY, 2015, 25 (05) : 1421 - 1430
  • [19] High-Pitch Dual-Source Computed Tomography Renal Angiography Comparison With Conventional Low-Pitch Computed Tomography Angiography: Image Quality, Contrast Medium Volume, and Radiation Dose
    Pang, LiFang
    Zhao, Yue
    Dong, HaiPeng
    Shi, HongCheng
    Yang, WenJie
    Zhang, Huan
    Yan, FuHua
    Liu, Bo
    Yan, Jing
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (05) : 737 - 740
  • [20] Feasibility of Low Volume of High-Concentration Iodinated Contrast Medium With 70 kVp Tube Voltage on High-Pitch Dual-Source Computed Tomography Angiography in Children With Congenital Heart Disease
    Nie, Pei
    Guo, Jian
    Yang, Zhitao
    Li, Xiaoli
    Yang, Guangjie
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (01) : 52 - 58