Reduced order model of a two-phase loop thermosyphon by modal identification method

被引:5
作者
Bodjona, Serge [1 ]
Girault, Manuel [1 ]
Videcoq, Etienne [1 ]
Bertin, Yves [1 ]
机构
[1] Univ Poitiers, CNRS, Inst Pprime, Dept Fluides,Therm,Combust,ENSMA, Teleport 2,1 Ave Clement Ader,BP 40109, F-86961 Futuroscope, France
关键词
Stiffened gas equation of state; Two-phase flows model; Compressible flow; Galerkin projection; Low order model; Parameter estimation; LOW THERMODYNAMIC QUALITY; NATURAL CIRCULATION; NUCLEAR-REACTORS; CAREM-25; REACTOR; GALERKIN METHOD; SYSTEM; FLOW; OPTIMIZATION; PERFORMANCE; SIMULATION;
D O I
10.1016/j.ijheatmasstransfer.2018.02.075
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study focuses on the model reduction of a two-phase loop thermosyphon. The aim is to propose a nonlinear reduced order model able to mimic the thermo-hydraulic behavior of the loop in order to use it for real-time state feedback control, in future applications. First, the one-dimensional two-phase flow model describing the liquid-gas mixture in both mechanical and thermal equilibrium is recalled. The numerical resolution of this detailed model is carried out using a finite volume approach and a Harten-Lax-van Leer Contact Riemann solver. Then, from this detailed model, a new structure of reduced model is determined via the Galerkin projection method. These reduced models, built by the Modal Identification Method, show a very good agreement between the outputs of the detailed model and those computed by the reduced model, during the identification stage. Two test cases, corresponding to different thermal loads at the evaporator, show that the overall levels of density, velocity, mass flow rate, pressure, temperature and internal energy in the loop are satisfactorily reproduced by the reduced model with a global relative error less than 5%. The interest of using such a model lies in the significant gain in CPU time. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:637 / 654
页数:18
相关论文
共 33 条
[1]   Non-incremental transient solution of the Rayleigh-Benard convection model by using the PGD [J].
Aghighi, M. S. ;
Ammar, A. ;
Metivier, C. ;
Normandin, M. ;
Chinesta, F. .
JOURNAL OF NON-NEWTONIAN FLUID MECHANICS, 2013, 200 :65-78
[2]   Numerical investigation on effect of riser diameter and inclination on system parameters in a two-phase closed loop thermosyphon solar water heater [J].
Aung, Nay Zar ;
Li, Songjing .
ENERGY CONVERSION AND MANAGEMENT, 2013, 75 :25-35
[3]   Comparison between the modal identification method and the POD-Galerkin method for model reduction in nonlinear diffusive systems [J].
Balima, O. ;
Favennec, Y. ;
Girault, M. ;
Petit, D. .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 2006, 67 (07) :895-915
[4]   Application of POD-based dynamical systems to dispersion and deposition of particles in turbulent channel flow [J].
Beghein, C. ;
Allery, C. ;
Waclawczyk, M. ;
Pozorski, J. .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2014, 58 :97-113
[5]  
Bielinski H., 2011, Heat Transfer, DOI [10.5772/13768, DOI 10.5772/13768]
[6]   Transient simulation of a two-phase loop thermosyphon with a model out of thermodynamic equilibrium [J].
Bodjona, S. ;
Videcoq, E. ;
Saurel, R. ;
Chinnayya, A. ;
Benselama, A. M. ;
Bertin, Y. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 108 :2321-2332
[7]   Experimental thermal regulation of an ultra-high precision metrology system by combining Modal Identification Method and Model Predictive Control [J].
Bouderbala, K. ;
Nouira, H. ;
Girault, M. ;
Videcoq, E. .
APPLIED THERMAL ENGINEERING, 2016, 104 :504-515
[8]   Reduced-order modeling of transonic flows around an airfoil submitted to small deformations [J].
Bourguet, Remi ;
Braza, Marianna ;
Dervieux, Alain .
JOURNAL OF COMPUTATIONAL PHYSICS, 2011, 230 (01) :159-184
[9]   Goal-oriented, model-constrained optimization for reduction of large-scale systems [J].
Bui-Thanh, T. ;
Willcox, K. ;
Ghattas, O. ;
Waanders, B. van Bloemen .
JOURNAL OF COMPUTATIONAL PHYSICS, 2007, 224 (02) :880-896
[10]   Theoretical and experimental investigations of a two-phase thermosyphon solar water heater [J].
Chien, C. C. ;
Kung, C. K. ;
Chang, C. C. ;
Lee, W. S. ;
Jwo, C. S. ;
Chen, S. L. .
ENERGY, 2011, 36 (01) :415-423