Additional Intrastromal Corneal Ring Segments in Keratoconus

被引:2
作者
Hashemi, Hassan [1 ]
Nabavi, Amin [1 ]
Bayat, Reza [1 ]
Mohebbi, Masoumeh [1 ]
机构
[1] Univ Tehran Med Sci, Farabi Eye Hosp, Eye Res Ctr, Qazvin Sq, Tehran 1336616351, Iran
关键词
keratoconus; intrastromal corneal ring segment; KeraRing; FOLLOW-UP; IMPLANTATION; OUTCOMES; INTACS; MODELS; EYES;
D O I
10.1097/ICO.0000000000001519
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the outcome of additional KeraRing (Mediphacos, Belo Horizonte, Brazil) implantation in patients with keratoconus with previously implanted INTACS (Addition Technology Inc, Fremont, CA) segments. Methods: The KeraRing was implanted in 5 eyes of 3 patients with keratoconus without removal of previous intrastromal corneal ring segments. Tunnels were created manually Snellen uncorrected distance visual acuity (UDVA), corrected distance visual acuity, refractive and keratometric values, and higher-order aberrations were recorded before and after KeraRing implantation. Results: UDVA, corrected distance visual acuity, subjective refraction, and keratometric values were improved in 4/5 of cases and remained stable during a median follow-up of 36 months. UDVA improved from 20/200 and 20/100 to 20/100 and 20/40 in the right and left eyes of patient 1, respectively, and from 20/200 to 20/40 in both eyes of patient 2. The reduction in mean keratometric value was 2.1 and 4.4 D in the right and left eyes of patient 1, and 1.4 and 1.9 D in the right and left eyes of patient 2, respectively. In patient 3, UDVA (20/100) and mean keratometric value (52.4) remained unchanged after second intrastromal corneal ring segment implantation. Total higher-order aberrations were improved in all cases. No intraoperative or postoperative complication was observed. However, one of the cases reported glare under scotopic conditions. Conclusions: KeraRing implantation in properly selected eyes with previously implanted INTACS could enhance final visual and refractive outcomes.
引用
收藏
页码:574 / 579
页数:6
相关论文
共 50 条
[31]   Enhanced effect of double-stacked intrastromal corneal ring segments in keratoconus [J].
Feldman, Brad H. ;
Kim, Terry .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (02) :332-335
[32]   Deep Anterior Lamellar Keratoplasty in Eyes With Intrastromal Corneal Ring Segments [J].
Ravera, Vittoria ;
Bovone, Cristina ;
Scorcia, Vincenzo ;
D'Angelo, Sergio ;
Busin, Massimo .
CORNEA, 2019, 38 (05) :642-644
[33]   Comparison of Complication Rates between Manual and Femtosecond Laser-Assisted Techniques for Intrastromal Corneal Ring Segments Implantation in Keratoconus [J].
Monteiro, Tiago ;
Alfonso, Jose F. ;
Freitas, Rui ;
Franqueira, Nuno ;
Faria-Correira, Fernando ;
Ambrosio, Renato ;
Madrid-Costa, David .
CURRENT EYE RESEARCH, 2019, 44 (12) :1291-1298
[34]   Clinical outcomes after intrastromal corneal ring segments reoperation in keratoconus patients [J].
Lconardo Torquetti ;
Guilherme Ferrara ;
Franklin Almeida ;
Leandro Cunha ;
Paulo Ferrara ;
Jesus Merayo-Lloves .
International Journal of Ophthalmology, 2013, (06) :796-800
[35]   Late onset of deep corneal vascularization: a rare complication of intrastromal corneal ring segments for keratoconus [J].
Cosar, Cemile Banu ;
Sridhar, M. S. ;
Sener, Bozkurt .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2009, 19 (02) :298-300
[36]   Efficacy of Intrastromal Corneal Ring Segments Combined With Flash Collagen Cross-Linking in Keratoconus [J].
Gordillo, Carlos H. ;
Grandin, Juan C. ;
Zaldivar, Roger ;
Zaldivar, Roberto ;
Lotfi, Adriana C. .
CORNEA, 2017, 36 (02) :144-147
[37]   Investigation of the efficiency of intrastromal ring segments with cross-linking using different sequence and timing for keratoconus [J].
Liu, Xuan-Li ;
Li, Ping-Hua ;
Fournie, Pierre ;
Malecaze, Francois .
INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (04) :703-708
[38]   Intrastromal corneal ring segments and posterior chamber phakic intraocular lens implantation for keratoconus correction [J].
Alfonso, Jose F. ;
Lisa, Carlos ;
Fernandez-Vega, Luis ;
Madrid-Costa, David ;
Poo-Lopez, Arancha ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (04) :706-713
[39]   Clinical Outcomes After Implantation of 320°-Arc Length Intrastromal Corneal Ring Segments in Keratoconus [J].
Torquetti, Leonardo ;
Cunha, Priscila ;
Luz, Allan ;
Kwitko, Sergio ;
Carrion, Marcio ;
Rocha, Guilherme ;
Signorelli, Armando ;
Coscarelli, Sandro ;
Ferrara, Guilherme ;
Bicalho, Frederico ;
Neves, Renato ;
Ferrara, Paulo .
CORNEA, 2018, 37 (10) :1299-1305
[40]   Corneal higher-order aberrations after crosslinking and intrastromal corneal ring segments for keratoconus [J].
Greenstein, Steven A. ;
Chung, Daniel ;
Rosato, Lauren ;
Gelles, John D. ;
Hersh, Peter S. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (07) :979-985