A novel miniaturized extraction capillary for determining gaseous formaldehyde by high-performance liquid chromatography

被引:19
作者
Ueta, Ikuo [1 ]
Mochizuki, Suguru [1 ]
Kawakubo, Susumu [1 ]
Kuwabara, Tetsuo [1 ]
Jinno, Kiyokatsu [2 ]
Saito, Yoshihiro [2 ]
机构
[1] Univ Yamanashi, Dept Appl Chem, Kofu, Yamanashi 4008511, Japan
[2] Toyohashi Univ Technol, Dept Environm & Life Sci, Toyohashi, Aichi 4418580, Japan
基金
日本学术振兴会;
关键词
Formaldehyde; Derivatization; Sample preparation; High-performance liquid chromatography; Miniaturization; SOLID-PHASE EXTRACTION; VOLATILE ORGANIC-COMPOUNDS; SAMPLE PREPARATION; INDOOR AIR; NEEDLE; DEVICE; BREATH;
D O I
10.1007/s00216-014-8144-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel miniaturized sample extraction capillary was developed to provide a simple and sensitive method for analyzing gaseous formaldehyde (FA) using conventional high-performance liquid chromatography (HPLC). The extraction capillary was prepared by packing silica gel particles in a stainless steel capillary with a 1.6-mm o.d. Before the gaseous samples were collected, the silica gel particles were impregnated with a derivatizing reagent 2,4-dinitrophenylhydrazine (DNPH) by passing a solution of DNPH through the extraction capillary. FA was derivatized to form the corresponding hydrazone during the active sampling of a gaseous sample, and the derivative was sorbed by the silica gel. The capillary was then directly connected to a six-port valve, and desorption from the capillary and injection into the HPLC were achieved simultaneously by passing a solvent through the capillary. The run-to-run and device-to-device variabilities, as relative standard deviations, were both less than 6.9 %. The limit of detection for FA was 2.5 ng/L using a sampling volume of 100 mL, and a sample collection time of 2 min. Acetaldehyde and acetone in a gaseous sample could also be simultaneously extracted and determined using this method. The applicability of the developed method for determining FA in real indoor air samples was confirmed by comparing the results obtained using the proposed method and a conventional sample preparation method. The developed method enables the rapid and simple sample preparation of gaseous FA and gives a good level of sensitivity.
引用
收藏
页码:899 / 905
页数:7
相关论文
共 29 条
[1]  
[Anonymous], 2011, 160003 ISO
[2]  
ASTM, 2003, D519703 ASTM
[3]   Development of SPME on-fiber derivatization for the sampling of formaldehyde and other carbonyl compounds in indoor air [J].
Bourdin, Delphine ;
Desauziers, Valerie .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (01) :317-328
[4]   On-line Coupling of Solid-Phase Extraction to Liquid Chromatography-A Review [J].
Chen, Ligang ;
Wang, Hui ;
Zeng, Qinglei ;
Xu, Yang ;
Sun, Lei ;
Xu, Haoyan ;
Ding, Lan .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2009, 47 (08) :614-623
[5]   Recent developments in solid phase extraction in elemental speciation of environmental samples with special reference to aqueous solutions [J].
Das, Debasis ;
Gupta, Utpal ;
Das, Arabinda K. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2012, 38 :163-171
[6]  
IARC Working Group on the Evaluation of Carcinogenic Risks to Humans, 2006, IARC Monogr Eval Carcinog Risks Hum, V88, P1
[7]   In-valve sample preparation cartridge designed for microcolumn liquid chromatography [J].
Imaizumi, M ;
Saito, Y ;
Ban, K ;
Wada, H ;
Hayashida, M ;
Jinno, K .
CHROMATOGRAPHIA, 2004, 60 (11-12) :619-623
[8]   Rapid On-Site Air Sampling with a Needle Extraction Device for Evaluating the Indoor Air Environment in School Facilities [J].
Inoue, Mitsuru ;
Mizuguchi, Ayako ;
Ueta, Ikuo ;
Takahashi, Kazuya ;
Saito, Yoshihiro .
ANALYTICAL SCIENCES, 2013, 29 (05) :519-525
[9]   Miniaturized sample preparation using a fiber-packed capillary as the medium [J].
Jinno, Kiyokatsu ;
Ogawa, Mitsuhiro ;
Ueta, Ikuo ;
Saito, Yoshihiro .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2007, 26 (01) :27-35