SUPER-RESOLUTION ULTRASOUND LOCALIZATION MICROSCOPY ON A RABBIT LIVER VX2 TUMOR MODEL: AN INITIAL FEASIBILITY STUDY

被引:24
作者
Zhang, Wei [1 ,2 ,3 ]
Lowerison, Matthew R. [1 ,2 ]
Dong, Zhijie [1 ,2 ]
Miller, Rita J. [1 ,2 ]
Keller, Krista A. [4 ]
Song, Pengfei [1 ,2 ,5 ]
机构
[1] Univ Illinois, Beckman Inst Adv Sci & Technol, Urbana, IL 61801 USA
[2] Univ Illinois, Dept Elect & Comp Engn, 1406 W Green St, Urbana, IL 61801 USA
[3] Tongji Hosp, Tongji Med Coll, Dept Med Ultrasound, Wuhan, Peoples R China
[4] Univ Illinois, Dept Vet Clin Med, Urbana, IL 61801 USA
[5] Univ Illinois, Canc Ctr Illinois, Urbana, IL USA
基金
美国国家卫生研究院;
关键词
Super-resolution; Contrast agents; Microbubbles; Microvessels; Cancer; Liver; Animal model; Ultrasound-localization microscopy; Rabbit; VX2; SORAFENIB; CHEMOEMBOLIZATION; ISOFLURANE; RESOLUTION; TRACKING; CANCER;
D O I
10.1016/j.ultrasmedbio.2021.04.012
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasound localization microscopy can image microvasculature in vivo without sacrificing imaging penetration depth. However, the reliance on super-resolution inference limits the applicability of the technique because subpixel tissue motion can corrupt microvascular reconstruction. Consequently, the majority of previous pre-clinical research on this super-resolution procedure has been restricted to low-motion experimental models with ample motion correction or data rejection, which precludes the imaging of organ sites that exhibit a high degree of respiratory and other motion. In this article, we present a novel anesthesia protocol in rabbits that induces safe, controllable periods of apnea to enable the long image-acquisition times required for ultrasound localization microscopy. We apply this protocol to a VX2 liver tumor model undergoing sorafenib therapy and compare the results to super-resolution images from conventional high-dose isoflurane anesthesia. We find that the apneic protocol was necessary to correctly identify the poorly vascularized tumor cores, as verified by immunohistochemistry, and to reveal the tumoral microvascular architecture. (C) 2021 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:2416 / 2429
页数:14
相关论文
共 41 条
[11]   Resolution limits of ultrafast ultrasound localization microscopy [J].
Desailly, Yann ;
Pierre, Juliette ;
Couture, Olivier ;
Tanter, Mickael .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (22) :8723-8740
[12]   Ultrafast ultrasound localization microscopy for deep super-resolution vascular imaging [J].
Errico, Claudia ;
Pierre, Juliette ;
Pezet, Sophie ;
Desailly, Yann ;
Lenkei, Zsolt ;
Couture, Olivier ;
Tanter, Mickael .
NATURE, 2015, 527 (7579) :499-+
[13]   Ultrasound localization microscopy to image and assess microvasculature in a rat kidney [J].
Foiret, Josquin ;
Zhang, Hua ;
Ilovitsh, Tali ;
Mahakian, Lisa ;
Tam, Sarah ;
Ferrara, Katherine W. .
SCIENTIFIC REPORTS, 2017, 7
[14]   Hepatocellular carcinoma [J].
Forner, Alejandro ;
Reig, Maria ;
Bruix, Jordi .
LANCET, 2018, 391 (10127) :1301-1314
[15]   Correlation of Doxorubicin Delivery and Tumor Necrosis after Drug-eluting Bead Transarterial Chemoembolization of Rabbit VX2 Liver Tumors [J].
Gaba, Ron C. ;
Emmadi, Rajyasree ;
Parvinian, Ahmad ;
Casadaban, Leigh C. .
RADIOLOGY, 2016, 280 (03) :752-761
[16]   Transarterial Sorafenib Chemoembolization: Preliminary Study of Technical Feasibility in a Rabbit Model [J].
Gaba, Ron C. ;
Yap, Felix Y. ;
Martinez, Elizabeth M. ;
Li, Yongchao ;
Guzman, Grace ;
Parvinian, Ahmad ;
van Breemen, Richard B. ;
Kumar, Nishant .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2013, 24 (05) :744-750
[17]   Mice Anesthesia, Analgesia, and Care, Part I: Anesthetic Considerations in Preclinical Research [J].
Gargiulo, Sara ;
Greco, Adelaide ;
Gramanzini, Matteo ;
Esposito, Silvia ;
Affuso, Andrea ;
Brunetti, Arturo ;
Vesce, Giancarlo .
ILAR JOURNAL, 2012, 53 (01) :E55-E69
[18]   Two-Stage Motion Correction for Super-Resolution Ultrasound Imaging in Human Lower Limb [J].
Harput, Sevan ;
Christensen-Jeffries, Kirsten ;
Brown, Jemma ;
Li, Yuanwei ;
Williams, Katherine J. ;
Davies, Alun H. ;
Eckersley, Robert J. ;
Dunsby, Christopher ;
Tang, Meng-Xing .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2018, 65 (05) :803-814
[19]   Microvascular flow dictates the compromise between spatial resolution and acquisition time in Ultrasound Localization Microscopy [J].
Hingot, Vincent ;
Errico, Claudia ;
Heiles, Baptiste ;
Rahal, Line ;
Tanter, Mickael ;
Couture, Olivier .
SCIENTIFIC REPORTS, 2019, 9 (1)
[20]   Subwavelength motion-correction for ultrafast ultrasound localization microscopy [J].
Hingot, Vincent ;
Errico, Claudia ;
Tanter, Mickael ;
Couture, Olivier .
ULTRASONICS, 2017, 77 :17-21