Assessment and Comparison of Anterior Chamber Dimensions Using Various Imaging Techniques

被引:11
作者
Dinc, Umut Asli [1 ]
Oncel, Banu [1 ]
Gorgun, Ebru [1 ]
Yenerel, Melda Nursal [1 ]
Alimgil, Levent [1 ]
机构
[1] Yeditepe Univ, Hosp Eye, Dept Ophthalmol, TR-34349 Istanbul, Turkey
关键词
OPTICAL COHERENCE TOMOGRAPHY; IMPLANTABLE CONTACT-LENS; PHAKIC INTRAOCULAR-LENS; CORNEAL DIAMETER; HIGH MYOPIA; SEGMENT;
D O I
10.3928/15428877-20091230-21
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BACKGROUND AND OBJECTIVE: To assess and compare the horizontal dimensions of the anterior chamber by different anterior segment imaging techniques. PATIENTS AND METHODS: Eighty eyes of 40 patients without any ocular disease or previous ocular Surgery were recruited and three consecutive measurements of internal anterior chamber diameter and white-to-white distance (WTW) parameters were determined. RESULTS: Mean internal anterior chamber diameter was 11.80 +/- 0.39, 11.56 +/- 0.47, and 11.61 +/- 0.58 mm with Visante-OCT SL-OCT, and Pentacam, respectively. Mean WTW distance was 11.87 +/- 0.35 and 11.65 +/- 0.32 mm by IOLMaster and OrbscanIIz, respectively There was no significant difference between Visante-OCT and Pentacam, IOLMaster, and OrbscanIIz (P = .125, .918, and .314). However, detection of mean internal anterior chamber diameter was significantly greater by Visante-OCT than SL-OCT (P = .026). All devices displayed a high intrasession repeatability (repeated measured ANOVA, P > .05). CONCLUSION: Internal anterior chamber diameter measurements using Visante-OCT, SL-OCT, and Pentacam, and WTW measurements using IOLMaster and OrbscanIIz were easy to handle and demonstrated good repeatability Although similar results of horizontal anterior chamber diameter were determined by Visante-OCT, Pentacam, IOLMaster, and OrbscanIIz, the inter-device differences should be considered during clinical practice.
引用
收藏
页码:115 / 122
页数:8
相关论文
共 25 条
[1]  
Apple D J, 2001, Trans Am Ophthalmol Soc, V99, P95
[2]   Phakic posterior chamber lenses for high myopia: Functional and anatomical outcomes [J].
Arne, JL ;
Lesueur, LC .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (03) :369-374
[3]   Measurement of the internal diameter and depth of the anterior chamber: IOLMaster versus anterior chamber optical coherence tomographer [J].
Baikoff, G ;
Jodai, HJ ;
Bourgeon, G .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09) :1722-1728
[4]   Anterior segment OCT and phakic intraocular lenses:: A perspective [J].
Baikoff, Georges .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (11) :1827-1835
[5]   Comparison of manual and automated methods to determine horizontal corneal diameter [J].
Baumeister, M ;
Terzi, E ;
Ekici, Y ;
Kohnen, T .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (02) :374-380
[6]  
Bloomenstein Marc R, 2002, Optometry, V73, P435
[7]   Anterior segment imaging: New milestones, new challenges [J].
Dupps, William J., Jr. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (11) :1779-1783
[8]   Anterior chamber width measurement by high speed optical coherence tomography [J].
Goldsmith, JA ;
Li, Y ;
Chalita, MR ;
Westphal, V ;
Patil, CA ;
Rollins, AM ;
Izatt, JA ;
Huang, D .
OPHTHALMOLOGY, 2005, 112 (02) :238-244
[9]   Implantable contact lens for moderate to high myopia - Relationship of vaulting to cataract formation [J].
Gonvers, M ;
Bornet, C ;
Othenin-Girard, P .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (05) :918-924
[10]   Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis [J].
Haigis, W ;
Lege, B ;
Miller, N ;
Schneider, B .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 238 (09) :765-773