The Validity of In Vivo Tooth Volume Determinations From Cone-Beam Computed Tomography

被引:70
作者
Liu, Yi [2 ]
Olszewski, Raphael [3 ]
Alexandroni, Emanuel Stefan [4 ]
Enciso, Reyes [1 ]
Xu, Tianmin [2 ]
Mah, James K. [1 ]
机构
[1] Univ So Calif, Sch Dent, Los Angeles, CA 90089 USA
[2] Peking Univ, Dept Orthodont, Sch Stomatol, Beijing 100871, Peoples R China
[3] Catholic Univ Louvain, Dept Oral & Maxillofacial Surg, Clin Univ St Luc, B-1200 Brussels, Belgium
[4] Univ So Calif, Sch Dent, Div Craniofacial Sci & Therapeut, Los Angeles, CA 90089 USA
关键词
Tooth volume; Cone-beam CT; Segmentation; Radiographic; Orthodontic; ACCURACY; CT; QUALITY;
D O I
10.2319/121608-639.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To determine the accuracy of volumetric analysis of teeth in vivo using cone-beam computed tomography (CBCT). Materials and Methods: The physical volume (Vw) of 24 bicuspids extracted for orthodontic purposes (16 were imaged with the I-CAT and 8 with the CB MercuRay) were determined using the water displacement technique. Corresponding pretreatment CBCT image data were uploaded into Amira 4.0 for segmentation and radiographic volume (Va). All measurements were performed twice by two observers. The statistical difference between Vw and Va was assessed using a paired Hest. The intraobserver and interobserver reliability were determined by calculating Pearson correlation coefficients and intraclass correlation coefficients. Results: The overall mean Vw of teeth specimens was 0.553 +/- 0.082 cm(3), while the overall mean Va was 0.548 +/- 0.079 cm(3) (0.529 +/- 0.078 cm(3) for observer 1 and 0.567 +/- 0.085 cm(3) for observer 2). There were statistically significant differences between Va and Vw (P < .05). Between observer 1 and observer 2, Va measurements were statistically significantly different (P < .05). The interobserver and intraobserver correlation coefficient for Vw was high. Lastly, surface smoothing reduced the volume by 3% to 12%. Conclusions: In vivo determination of tooth volumes from CBCT data is feasible. The measurements slightly deviate from the physical volumes within -4% to 7%. Smoothing operations reduce volume measurements. Currently, no requirements for accuracy of volumetric determinations of tooth volume have been established. (Angle Orthod. 2010;80:160-166.)
引用
收藏
页码:160 / 166
页数:7
相关论文
共 27 条
[1]   Determination of the Hounsfield value for CT-based design of custom femoral stems [J].
Aamodt, A ;
Kvistad, KA ;
Andersen, E ;
Lund-Larsen, J ;
Eine, J ;
Benum, P ;
Husby, OS .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (01) :143-147
[2]   Volumetric analysis of extraction sockets using cone beam computed tomography: a pilot study on ex vivo jaw bone [J].
Agbaje, Jimoh Olubanwo ;
Jacobs, Reinhilde ;
Maes, Frederik ;
Michiels, Katleen ;
van Steenberghe, Daniel .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2007, 34 (11) :985-990
[3]   ROOT SURFACE MEASUREMENTS OF MANDIBULAR MOLARS USING STEREOPHOTOGRAMMETRY [J].
ANDERSON, RW ;
MCGARRAH, HE ;
LAMB, RD ;
EICK, JD .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1983, 107 (04) :613-615
[4]   METHOD OF MEASURING ROOT AREAS OF EXTRACTED TEETH [J].
CRABB, JJ ;
WILSON, HJ .
JOURNAL OF DENTISTRY, 1974, 2 (04) :171-174
[5]   VOLUME MEASUREMENTS OF NORMAL ORBITAL STRUCTURES BY COMPUTED TOMOGRAPHIC ANALYSIS [J].
FORBES, G ;
GEHRING, DG ;
GORMAN, CA ;
BRENNAN, MD ;
JACKSON, IT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 145 (01) :149-154
[6]  
Garino Francesco, 2005, Prog Orthod, V6, P214
[7]  
Garino Francesco, 2004, Prog Orthod, V5, P248
[8]   A new technique for the creation of a computerized composite skull model [J].
Gateno, J ;
Xia, J ;
Teichgraeber, JF ;
Rosen, A .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2003, 61 (02) :222-227
[9]   In search of anatomic truth: 3-dimensional digital modeling and the future of orthodontics [J].
Harrell, WE ;
Hatcher, DC ;
Bolt, RL .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2002, 122 (03) :325-330
[10]   Cone-beam computed tomography in orthodontics: Benefits and limitations; [Die Digitale Volumentomographie in der Kieferorthopädie: Möglichkeiten und Grenzen] [J].
Holberg C. ;
Steinhäuser S. ;
Geis P. ;
Rudzki-Janson I. .
Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 2005, 66 (6) :434-444