A Highly Sensitive Hydrogen Peroxide Biosensor Based on Hemoglobin Immobilized on Cadmium Sulfide Quantum Dots/Chitosan Composite Modified Glassy Carbon Electrode

被引:13
|
作者
Butwong, Nutthaya [1 ]
Zhou, Lin [2 ,3 ]
Moore, Eric [2 ,3 ,4 ,5 ]
Srijaranai, Supalax [4 ,5 ]
Luong, John H. T. [2 ,3 ]
Glennon, Jeremy D. [2 ,3 ]
机构
[1] Rajamangala Univ Technol, Fac Sci & Liberal Arts, Dept Appl Chem, Nakhon 30000, Ratchasima, Thailand
[2] Natl Univ Ireland Univ Coll Cork, Innovat Chromatog Grp, ISSC, Dept Chem, Cork, Ireland
[3] Natl Univ Ireland Univ Coll Cork, ABCRF, Cork, Ireland
[4] Khon Kaen Univ, Fac Sci, Dept Chem, Khon Kaen 40002, Thailand
[5] Khon Kaen Univ, Ctr Innovat Chem, Fac Sci, Khon Kaen 40002, Thailand
基金
爱尔兰科学基金会;
关键词
Hemoglobin; Cadmium sulphide; Quantum dots; Chitosan; Hydrogen peroxide; LAYER-BY-LAYER; DIRECT ELECTROCHEMISTRY; FLUORESCENCE PROBE; AQUEOUS-SOLUTION; IONIC LIQUID; CHITOSAN; DOTS; NANOPARTICLES; NANOTUBES; FILMS;
D O I
10.1002/elan.201400353
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An L-cysteine capped cadmium sulfide-chitosan nanocomposite has been synthesized, characterized and used for surface modification of a glassy carbon electrode. With direct electron transfer, hemoglobin (Hb) adsorbed strongly on the nanocomposite and displayed excellent bioelectrocatalysis for H2O2. The biosensor was capable of reducing H2O2 at -0.35 V, with a detection limit of 3.13 nM, linearity in the range of 15 nM to 10 mu M and a response time of less than 2 s. The Michaelis-Menten constant (K-M) was 0.57 nM, attesting high bioelectrocatalysis of immobilized Hb for H2O2. Reproducibility of the fabrication method was very satisfactory with a relative standard deviation of 5.3%. The biosensor lost only 6.5% of its original response after 7 days when stored in a pH 7.4 PBS at 4 degrees C.
引用
收藏
页码:2465 / 2473
页数:9
相关论文
共 50 条
  • [21] Biosensor for Hydrogen Peroxide Based on Chitosan and Nanoparticle Complex Film-Modified Glassy-Carbon Electrodes
    Xu, Qiao
    Wang, Jian-Hao
    Wang, Zhan
    Wang, Hai-Qiao
    Yang, Qin
    Zhao, Yuan-Di
    ANALYTICAL LETTERS, 2009, 42 (15) : 2496 - 2508
  • [22] A glassy carbon electrode modified with FeS nanosheets as a highly sensitive amperometric sensor for hydrogen peroxide
    Jin, Jiayi
    Wu, Wenqin
    Min, Hui
    Wu, Huimin
    Wang, Shengfu
    Ding, Yu
    Yang, Shuijin
    MICROCHIMICA ACTA, 2017, 184 (05) : 1389 - 1396
  • [23] Immobilization of Hemoglobin on the Gold Colloid Modified Pretreated Glassy Carbon Electrode for Preparing a Novel Hydrogen Peroxide Biosensor
    Yang Liu
    Qi-Yu Jiang
    Shuang-Yun Lu
    Ye Zhang
    Hai-Ying Gu
    Applied Biochemistry and Biotechnology, 2009, 152 : 418 - 427
  • [24] A sensitive amperometric hydrogen peroxide sensor based on thionin/EDTA/carbon nanotubes—chitosan composite film modified electrode
    Keying Zhang
    Li Zhang
    Jigui Xu
    Cong Wang
    Tao Geng
    Hongyan Wang
    Jun Zhu
    Microchimica Acta, 2010, 171 : 139 - 144
  • [25] A glassy carbon electrode modified with SnO2 nanofibers, polyaniline and hemoglobin for improved amperometric sensing of hydrogen peroxide
    Kafi, A. K. M.
    Wali, Qamar
    Jose, Rajan
    Biswas, Tapan Kumar
    Yusoff, Mashitah M.
    MICROCHIMICA ACTA, 2017, 184 (11) : 4443 - 4450
  • [26] Amperometric hydrogen peroxide biosensor based on a glassy carbon electrode modified with polythionine and gold nanoparticles
    Wang, Qingxia
    Zhang, Haili
    Wu, Yiwei
    Yu, Aimin
    MICROCHIMICA ACTA, 2012, 176 (3-4) : 279 - 285
  • [27] A hydrogen peroxide biosensor with high stability based on gelatin-multiwalled carbon nanotubes modified glassy carbon electrode
    Wang, Yulin
    Li, Tianyu
    Zhang, Weijie
    Huang, Yaqin
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2014, 18 (07) : 1981 - 1987
  • [28] Hydrogen peroxide sensor based on hemoglobin immobilized on glassy carbon electrode with SiO2 nanoparticles/chitosan film as immobilization matrix
    Zhang, H.
    Zou, X.
    Han, D.
    ANALYTICAL LETTERS, 2007, 40 (04) : 661 - 676
  • [29] A SENSITIVE HYDROGEN PEROXIDE SENSOR BASED ON HEMOGLOBIN IMMOBILIZED ON GOLD NANOPARTICLES AND 1,6-HEXANEDITHIOL MODIFIED GOLD ELECTRODE
    Liu, Chenyao
    Li, Shuoqi
    Jiao, Jiao
    Cao, Wei
    Hu, Jingbo
    Li, Qilong
    ANALYTICAL LETTERS, 2011, 44 (05) : 885 - 897
  • [30] Determination of Hydrogen Peroxide by Electrochemiluminescence Using a Chitosan-graphene Composite Film Doped Cadmium-Tellurium Quantum Dot Modified Glassy Carbon Electrode
    Pan, Qian-Xiu
    Wang, Jiang-Yun
    Cheng, Yuan-Zheng
    Li, Wen-Jing
    Wang, Xue-Dong
    ANALYTICAL LETTERS, 2018, 51 (09) : 1373 - 1383