Beryllium-stimulated neopterin as a diagnostic adjunct in chronic beryllium disease

被引:10
作者
Maier, LA
Kittle, LA
Mroz, MM
Newman, LS
机构
[1] Natl Jewish Med & Res Ctr, Dept Med, Div Environm & Occupat Hlth Sci, Denver, CO 80206 USA
[2] Univ Colorado, Ctr Hlth Sci, Dept Med, Div Pulm Sci & Crit Care Med, Denver, CO 80202 USA
[3] Univ Colorado, Ctr Hlth Sci, Dept Prevent Med & Biomet, Denver, CO 80202 USA
关键词
beryllium; berylliosis; biomarker; chronic beryllium disease; diagnosis; neopterin;
D O I
10.1002/ajim.10227
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background The diagnosis of chronic beryllium disease (CBD) relies on the beryllium lymphocyte proliferation test (BeLPT) to demonstrate a Be specific immune response. This test has improved early diagnosis, but cannot discriminate beryllium sensitization (BeS) from CBD. We previously found high neopterin levels in CBD patients' serum and questioned whether Be-stimulated neopterin production by peripheral blood cells in vitro might be useful in the diagnosis of CBD. Methods CBD, BeS, Be exposed workers without disease (Be-exp) normal controls and sarcoidosis subjects were enrolled. Peripheral blood mononuclear cells (PBMN) were cultured in the presence and absence of beryllium sulfate. Neopterin levels were determined from cell supernatants by enzyme linked immunosorbent assay (ELISA). Clinical evaluation of CBD subjects included chest radiography, pulmonary function testing, exercise testing, and the BeLPT Results CBD patients produced higher levels of neopterin in both unstimulated and Be-stimulated conditions compared to all other subjects (P<0.0001). Unstimulated neopterin mononuclear cell levels overlapped among groups, however, Be-stimulated neopterin levels in CBD showed little overlap. Using a neopterin concentration of 2.5 ng/ml as a cutoff, Be-stimulated neopterin had a sensitivity of 80% and specificity of 100% for CBD and was able to differentiate CBD from BeS. Be-stimulated neopterin was inversely related to measures of pulmonary function, exercise capacity, and gas exchange. Conclusions Neopterin maybe a useful diagnostic adjunct in the non-invasive assessment of CBD, differentiating CBD from BeS. Further studies will be required to determine how it performs in workplace screening. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:592 / 601
页数:10
相关论文
共 42 条
[1]   Urinary neopterin excretion and dihydropteridine reductase activity in rheumatoid arthritis [J].
Altindag, ZZ ;
Sahin, G ;
Inanici, F ;
Hascelik, Z .
RHEUMATOLOGY INTERNATIONAL, 1998, 18 (03) :107-111
[2]  
[Anonymous], GUID US ILO INT CLAS
[3]  
Blaschke E, 1988, Sarcoidosis, V5, P25
[4]  
CRAPO RO, 1981, AM REV RESPIR DIS, V123, P185
[5]   ELEVATED SERUM NEOPTERIN LEVELS IN SARCOIDOSIS [J].
EKLUND, A ;
BLASCHKE, E .
LUNG, 1986, 164 (06) :325-332
[6]  
FERRIS BG, 1971, AM REV RESPIR DIS, V104, P232
[7]  
GOLDMAN HI, 1959, AM REV TUBERC PULM, V79, P457
[8]   Neopterin: a review [J].
Hamerlinck, FFV .
EXPERIMENTAL DERMATOLOGY, 1999, 8 (03) :167-176
[9]  
Harris J, 1997, AM J IND MED, V32, P21, DOI 10.1002/(SICI)1097-0274(199707)32:1<21::AID-AJIM3>3.0.CO
[10]  
2-U