Flow injection renewable drops spectrofluorimetry for sequential determinations of Vitamins B1, B2 and B6

被引:34
作者
Feng, F
Wang, KM [1 ]
Chen, ZZ
Chen, QT
Lin, JD
Huang, SS
机构
[1] Hunan Univ, State Key Lab Chemo Biol Sensing & Chemometr, Coll Chem & Chem Engn, Changsha 410082, Peoples R China
[2] Datong Univ, Dept Chem, Datong 037009, Peoples R China
关键词
flow injection; droplet sensor; Sephadex; Vitamin B; spectrofluorimetry;
D O I
10.1016/j.aca.2004.09.037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel optical chemical sensor based on the dynamic liquid drops combined with flow injection-solid phase has been developed for continuous and sequential determinations of the mixture of Vitamin B-1, Vitamin B, and Vitamin B-6. The design and characteristics of the sensor system are described. The dynamically growing and falling drops serve as windowless optical cells. The adsorption, desorption and quantitative determinations of VB1, VB2 and VB6 were carried out based on selective adsorption of Sephadex CMC-25 and different fluorescence characteristics of VB2, VB6 in the basic solutions. The optimum analytical conditions for compound Vitamin B assay have been established. Under these conditions, linear calibration curves were obtained over the range of 0.01-8.00, 0.01-10.00 and 0.01-3.00 mug/ml for VB1 VB2 and VB6 with the limits of determination of 0.008, 0.005 and 0.006 mug/ml, respectively. This method has been applied in the determination of synthetic mixture of VB1, VB2, VB6 and Vitamin B compound tablets with satisfactory results. The technique, which has been described, provides a simple, effective and sensitive method to assay the biological samples. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:187 / 193
页数:7
相关论文
共 17 条
[1]   ANALYTICAL-CHEMISTRY IN A LIQUID-FILM DROPLET [J].
CARDOSO, AA ;
DASGUPTA, PK .
ANALYTICAL CHEMISTRY, 1995, 67 (15) :2562-2566
[2]  
*COMM HLTH MIN PEO, 1995, PHARM PEOPL REP CHIN, P816
[3]   MEASUREMENT OF GASES BY A SUPPRESSED CONDUCTOMETRIC CAPILLARY ELECTROPHORESIS SEPARATION SYSTEM [J].
DASGUPTA, PK ;
KAR, S .
ANALYTICAL CHEMISTRY, 1995, 67 (21) :3853-3860
[4]  
Feng F, 2004, CHEM J CHINESE U, V25, P1257
[5]  
Feng F, 2003, CHEM J CHINESE U, V24, P2189
[6]   Simultaneous on-line dissolution monitoring of multicomponent solid preparations containing vitamins B1, B2 [J].
Li, W ;
Chen, J ;
Xiang, BR ;
An, DK .
ANALYTICA CHIMICA ACTA, 2000, 408 (1-2) :39-47
[7]   Analytical chemistry in a drop [J].
Liu, HH ;
Dasgupta, PK .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (09) :468-475
[8]  
MAGDA B, 1986, PHARMAZIE, V41, P483
[9]   FLUOROMETRIC ANALYSIS ON INDIVIDUAL NANOLITER SAMPLE DROPLETS [J].
MAHONEY, PP ;
HIEFTJE, GM .
APPLIED SPECTROSCOPY, 1994, 48 (08) :956-958
[10]   An optimized method for the simultaneous determination of vitamins B1, B6, B12, in multivitamin tablets by high performance liquid chromatography [J].
Markopoulou, CK ;
Kagkadis, KA ;
Koundourellis, JE .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (04) :1403-1410