Fixed angle plate fixation of comminuted patellar fractures

被引:51
|
作者
Moore, Tyler B. [3 ]
Sampathi, Bharat R. [1 ]
Zamorano, David P. [2 ]
Tynan, Martin C. [1 ]
Scolaro, John A. [1 ]
机构
[1] Univ Calif Irvine, 101 City Dr South,Bldg 29A,Pavil 3,2nd Floor, Orange, CA 92668 USA
[2] St Alphonsus Med Ctr, Boise, ID USA
[3] Ashley Reg Med Ctr, Vernal, UT USA
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2018年 / 49卷 / 06期
关键词
Patella; Fracture; Locking plate; Comminuted; Complex; PARTIAL PATELLECTOMY; FUNCTIONAL OUTCOMES;
D O I
10.1016/j.injury.2018.03.030
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Comminuted patella fractures are uncommon and difficult fractures to manage. Multiple treatment modalities have been suggested, with little clinical data to support practice. Recent biomechanical and technical investigations have described successful plate fixation of comminuted patella fractures. The purpose of this study was to evaluate radiographic, clinical and functional outcome of comminuted patella fractures treated with a fixed angle locking plates. We believe stable fixation, which results in successful fracture union and functional recovery, can be achieved with this technique. Materials and methods: A retrospective review was performed at a single regional academic Level 1 trauma hospital. All comminuted patella fractures treated with a fixed angle locking plate (AO/OTA 34C2 and C3) over a six-year period were evaluated. Thirty-six patients were identified. Average length of follow up was 154 weeks (range 12-297 weeks). Twenty patients were available for functional outcome scoring. Primary outcome measures were: Knee Outcome Score (KOS), Lower Extremity Functional Scale (LES) and goniometer measured knee range of motion. Secondary outcomes evaluated the need for additional screw or cerclage fixation, reoperation for any reason, bothersome hardware, infection and nonunion. Results: Average KOS = 57.2 (20-74), average LES = 58.9 (15-80). Median extension = 0 degrees (full extension), median flexion = 130 degrees. Supplemental screws were used in 17/36 cases; cerclage used in 2/36 cases. Hardware irritation was noted in 4/20 patients, no patient requested elective hardware removal, one patient had failure of fixation and no nonunions were identified. Conclusion: Fixed angle plate stabilization of comminuted patella fractures is a viable technique for fracture fixation. Good to excellent return of knee function and low complication rates, including need for hardware removal, can be expected. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1203 / 1207
页数:5
相关论文
共 50 条
  • [41] Comminuted AO-C3 fractures of the patella: good outcome using anatomically contoured locking plate fixation
    Stefan Buschbeck
    Kristina Götz
    Alexander Klug
    Stefan Barzen
    Yves Gramlich
    Reinhard Hoffmann
    International Orthopaedics, 2022, 46 : 1395 - 1403
  • [42] Complications Associated with Distraction Plate Fixation of Wrist Fractures
    Hanel, Douglas P.
    Ruhlman, Scott David
    Katolik, Leo I.
    Allan, Christopher H.
    HAND CLINICS, 2010, 26 (02) : 237 - +
  • [43] Comminuted AO-C3 fractures of the patella: good outcome using anatomically contoured locking plate fixation
    Buschbeck, Stefan
    Goetz, Kristina
    Klug, Alexander
    Barzen, Stefan
    Gramlich, Yves
    Hoffmann, Reinhard
    INTERNATIONAL ORTHOPAEDICS, 2022, 46 (06) : 1395 - 1403
  • [44] Outcome Analysis of Fixed Angle Locking Plate in Patella Fractures: A Single Centre Experience from North India
    Saurabh Singh
    Rishabh Surana
    Alok Rai
    Divyansh Sharma
    Indian Journal of Orthopaedics, 2021, 55 : 655 - 661
  • [45] Outcome Analysis of Fixed Angle Locking Plate in Patella Fractures: A Single Centre Experience from North India
    Singh, Saurabh
    Surana, Rishabh
    Rai, Alok
    Sharma, Divyansh
    INDIAN JOURNAL OF ORTHOPAEDICS, 2021, 55 (03) : 655 - 661
  • [46] Minimally invasive plate osteosynthesis for comminuted fractures of the metaphysis of the radius
    Imatani, J
    Noda, T
    Morito, Y
    Sato, T
    Hashizume, H
    Inoue, H
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2005, 30B (02) : 220 - 225
  • [47] Biomechanical evaluation of internal fixation for the treatment of comminuted subtrochanteric femur fractures
    Tazawa, Ryo
    Minehara, Hiroaki
    Matsuura, Terumasa
    Kawamura, Tadashi
    Sakai, Rina
    Yoshida, Kazuhiro
    Inoue, Gen
    Takaso, Masashi
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2021, 26 (02) : 261 - 265
  • [48] Outcome of plate fixation of olecranon fractures
    Bailey, CS
    MacDermid, J
    Patterson, SD
    King, GJW
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (08) : 542 - 548
  • [49] Are angle-fixed implants with elastic properties advantageous for the internal fixation of proximal humerus fractures?
    Hessmann, MH
    Sternstein, W
    Mehler, D
    Korner, J
    Hofmann, A
    Rommens, PM
    BIOMEDIZINISCHE TECHNIK, 2004, 49 (12): : 345 - 350
  • [50] Separate Vertical Wiring for the Fixation of Comminuted Fractures of the Inferior Pole of the Patella
    Song, Hyung Keun
    Yoo, Je Hyun
    Byun, Young Soo
    Yang, Kyu Hyun
    YONSEI MEDICAL JOURNAL, 2014, 55 (03) : 785 - 791