Fixed angle plate fixation of comminuted patellar fractures

被引:51
|
作者
Moore, Tyler B. [3 ]
Sampathi, Bharat R. [1 ]
Zamorano, David P. [2 ]
Tynan, Martin C. [1 ]
Scolaro, John A. [1 ]
机构
[1] Univ Calif Irvine, 101 City Dr South,Bldg 29A,Pavil 3,2nd Floor, Orange, CA 92668 USA
[2] St Alphonsus Med Ctr, Boise, ID USA
[3] Ashley Reg Med Ctr, Vernal, UT USA
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2018年 / 49卷 / 06期
关键词
Patella; Fracture; Locking plate; Comminuted; Complex; PARTIAL PATELLECTOMY; FUNCTIONAL OUTCOMES;
D O I
10.1016/j.injury.2018.03.030
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Comminuted patella fractures are uncommon and difficult fractures to manage. Multiple treatment modalities have been suggested, with little clinical data to support practice. Recent biomechanical and technical investigations have described successful plate fixation of comminuted patella fractures. The purpose of this study was to evaluate radiographic, clinical and functional outcome of comminuted patella fractures treated with a fixed angle locking plates. We believe stable fixation, which results in successful fracture union and functional recovery, can be achieved with this technique. Materials and methods: A retrospective review was performed at a single regional academic Level 1 trauma hospital. All comminuted patella fractures treated with a fixed angle locking plate (AO/OTA 34C2 and C3) over a six-year period were evaluated. Thirty-six patients were identified. Average length of follow up was 154 weeks (range 12-297 weeks). Twenty patients were available for functional outcome scoring. Primary outcome measures were: Knee Outcome Score (KOS), Lower Extremity Functional Scale (LES) and goniometer measured knee range of motion. Secondary outcomes evaluated the need for additional screw or cerclage fixation, reoperation for any reason, bothersome hardware, infection and nonunion. Results: Average KOS = 57.2 (20-74), average LES = 58.9 (15-80). Median extension = 0 degrees (full extension), median flexion = 130 degrees. Supplemental screws were used in 17/36 cases; cerclage used in 2/36 cases. Hardware irritation was noted in 4/20 patients, no patient requested elective hardware removal, one patient had failure of fixation and no nonunions were identified. Conclusion: Fixed angle plate stabilization of comminuted patella fractures is a viable technique for fracture fixation. Good to excellent return of knee function and low complication rates, including need for hardware removal, can be expected. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1203 / 1207
页数:5
相关论文
共 50 条
  • [21] Helical plate fixation for treatment of comminuted fractures of the proximal and middle one-third of the humerus
    Yang, KH
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2005, 36 (01): : 75 - 80
  • [22] Complete exposure of the articular surface for fixation of patellar fractures
    Gardner, MJ
    Griffith, MH
    Lawrence, BD
    Lorich, DG
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2005, 19 (02) : 118 - 123
  • [23] Dual plate for comminuted proximal humerus fractures
    Choi, Sungwook
    Seo, Kyu-Bum
    Kwon, Yong Suk
    Kang, Hyunseong
    Cho, Changhee
    Rho, Joseph Y.
    ACTA ORTHOPAEDICA BELGICA, 2019, 85 (04): : 429 - 436
  • [24] Patellar Shape-Memory Fixator for the Treatment of Comminuted Fractures of the Inferior Pole of the Patella
    Xin-Wei Liu
    Hui-Juan Shang
    Shuo-Gui Xu
    Zhi-Wei Wang
    Chun-Cai Zhang
    Qing-Ge Fu
    Journal of Materials Engineering and Performance, 2011, 20 : 623 - 628
  • [25] Is there any difference between the biomechanical strengths of the current fixation techniques for comminuted distal patellar fractures? (Comparison of distal patella fracture fixation techniques)
    Kocadal, Onur
    Pepe, Murad
    Gunes, Zafer
    Aksahin, Ertugrul
    Duran, Sell
    Aktekin, Cem Nuri
    ACTA ORTHOPAEDICA BELGICA, 2017, 83 (04): : 550 - 557
  • [26] The palmar fixed angle plate in distal radius fractures - advantages and disadvantages
    Schmelzer-Schmied, N.
    Martini, A. K.
    Jung, M.
    OBERE EXTREMITAET-SCHULTER-ELLENBOGEN-HAND-UPPER EXTREMITY-SHOULDER ELBOW HAND, 2007, 2 (03): : 150 - 155
  • [27] Fragment reconstruction and bone plate fixation versus bridging plate fixation for treating highly comminuted femoral fractures in dogs: 35 cases (1987-1997)
    Johnson, AL
    Smith, CW
    Scheffer, DJ
    JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 1998, 213 (08) : 1157 - 1161
  • [28] Effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures
    Han, L. R.
    Jin, C. X.
    Yan, J.
    Han, S. Z.
    He, X. B.
    Yang, X. F.
    GENETICS AND MOLECULAR RESEARCH, 2015, 14 (01) : 2912 - 2919
  • [29] The use of dorsal distraction plating for severely comminuted distal radius fractures: A review and comparison to volar plate fixation
    Perlus, R.
    Doyon, J.
    Henry, P.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 : S50 - S55
  • [30] Meta-analysis shows that highly comminuted bicondylar tibial plateau fractures treated by single lateral locking plate give similar outcomes as dual plate fixation
    Hengrui Chang
    Yanbin Zhu
    Zhanle Zheng
    Wei Chen
    Shue Zhao
    Yiwen Zhang
    Yingze Zhang
    International Orthopaedics, 2016, 40 : 2129 - 2141