Functionality test for drug safety alerting in computerized physician order entry systems

被引:12
作者
van der Sijs, Heleen [1 ]
Bouamar, Rachida [1 ]
van Gelder, Teun [1 ,2 ]
Aarts, Jos [3 ]
Berg, Marc [3 ]
Vulto, Arnold [1 ]
机构
[1] Erasmus Univ, Med Ctr, Dept Hosp Pharm, NL-3000 CA Rotterdam, Netherlands
[2] Erasmus Univ, Med Ctr, Dept Internal Med, NL-3000 CA Rotterdam, Netherlands
[3] Erasmus Univ, Inst Hlth Policy & Management, Rotterdam, Netherlands
关键词
Medical order entry systems; Clinical decision support systems; Drug therapy computer-assisted; Safety management; Sensitivity and specificity; CLINICAL DECISION-SUPPORT; OPPORTUNITIES; OUTCOMES;
D O I
10.1016/j.ijmedinf.2010.01.005
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Purpose: To evaluate the functionality of drug safety alerting in hospital computerized physician order entry (CPOE) systems by a newly developed comprehensive test. Methods: Comparative evaluation of drug safety alerting quality in 6 different CPOEs used in Dutch hospitals, by means of 29 test items for sensitivity and 19 for specificity in offices of CPOE system vendors. Sensitivity and specificity were calculated for the complete test, and for the categories "within-order checks", "patient-specific checks", and "checks related to laboratory data and new patient conditions". Qualitative interviews with 16 hospital pharmacists evaluating missing functionality and corresponding pharmacy checks. Results: Sensitivity ranged from 0.38 to 0.79 and specificity from 0.11 to 0.84. The systems achieved the same ranking for sensitivity as for specificity. Within-order checks and patientspecific checks were present in all systems; alert generation or suppression due to laboratory data and new patient conditions was largely absent. Hospital pharmacists unanimously rated checks on contra-indications (absent in 2 CPOEs) and dose regimens less than once a day (absent in 4 CPOEs) as important. Pharmacists' opinions were more divergent for other test items. A variety of pharmacy checks were used, and clinical rules developed, to address missing functionality. Conclusions: Our test revealed widely varying functionality and appeared to be highly discriminative. Basic clinical decision support was partly absent in two CPOEs. Hospital pharmacists did not rate all test items as important and tried to accommodate the lacking functionality by performing additional checks and developing clinical rules. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:243 / 251
页数:9
相关论文
共 50 条
  • [41] Computerized physician order entry of medications and clinical decision support can improve problem list documentation compliance
    Galanter, William L.
    Hier, Daniel B.
    Jao, Chiang
    Sarne, David
    INTERNATIONAL JOURNAL OF MEDICAL INFORMATICS, 2010, 79 (05) : 332 - 338
  • [42] Translation and adaptation of a tool prescribing errors related to computerized physician order entry coding to the French hospital background
    Videau, Manon
    Charpiat, Bruno
    Conort, Ornella
    Janoly-Dumenil, Audrey
    Bedouch, Pierrick
    ANNALES PHARMACEUTIQUES FRANCAISES, 2023, 81 (06): : 1054 - 1071
  • [43] Core Drug-Drug Interaction Alerts for Inclusion in Pediatric Electronic Health Records With Computerized Prescriber Order Entry
    Harper, Marvin B.
    Longhurst, Christopher A.
    McGuire, Troy L.
    Tarrago, Rod
    Desai, Bimal R.
    Patterson, Al
    JOURNAL OF PATIENT SAFETY, 2014, 10 (01) : 59 - 63
  • [44] Improving the utilization of admission order sets in a computerized physician order entry system by integrating modular disease specific order subsets into a general medicine admission order set
    Munasinghe, Rajika L.
    Arsene, Camelia
    Abraham, Tarun K.
    Zidan, Marwan
    Siddique, Mohamed
    JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2011, 18 (03) : 322 - 326
  • [45] COMPUTERIZED PHYSICIAN ORDER ENTRY-BASED HYPERGLYCEMIA INPATIENT PROTOCOL AND GLYCEMIC OUTCOMES: THE CPOE-HIP STUDY
    Guerra, Yannis S.
    Das, Krishna
    Antonopoulos, Pete
    Borkowsky, Shane
    Fogelfeld, Leon
    Gordon, Melanie J.
    Palal, Betsy M.
    Witsil, Joanne C.
    Lacuesta, Evelyn A.
    ENDOCRINE PRACTICE, 2010, 16 (03) : 389 - 397
  • [46] Computerized prescriber order entry-related patient safety reports: analysis of 2522 medication errors
    Amato, Mary G.
    Salazar, Alejandra
    Hickman, Thu-Trang T.
    Quist, Arbor J. L.
    Volk, Lynn A.
    Wright, Adam
    McEvoy, Dustin
    Galanter, William L.
    Koppel, Ross
    Loudin, Beverly
    Adelman, Jason
    McGreevey, John D., III
    Smith, David H.
    Bates, David W.
    Schiff, Gordon D.
    JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2017, 24 (02) : 316 - 322
  • [47] Just what the doctor ordered. Review of the evidence of the impact of computerized physician order entry system on medication errors
    Shamliyan, Tatyana A.
    Duval, Sue
    Du, Jing
    Kane, Robert L.
    HEALTH SERVICES RESEARCH, 2008, 43 (01) : 32 - 53
  • [48] Implementation of Computerized Physician Order Entry Is Associated With Increased Thrombolytic Administration for Emergency Department Patients With Acute Ischemic Stroke
    Ballard, Dustin W.
    Kim, Anthony S.
    Huang, Jie
    Park, David K.
    Kene, Mamata V.
    Chettipally, Uli K.
    Iskin, Hilary R.
    Hsu, John
    Vinson, David R.
    Mark, Dustin G.
    Reed, Mary E.
    ANNALS OF EMERGENCY MEDICINE, 2015, 66 (06) : 601 - 610
  • [49] The impact of computerized provider order entry systems on medical-imaging services: a systematic review
    Georgiou, Andrew
    Prgomet, Mirela
    Markewycz, Andrew
    Adams, Edwina
    Westbrook, Johanna I.
    JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2011, 18 (03) : 335 - 340
  • [50] Use of order sets in inpatient computerized provider order entry systems: A comparative analysis of usage patterns at seven sites
    Wright, Adam
    Feblowitz, Joshua C.
    Pang, Justine E.
    Carpenter, James D.
    Krall, Michael A.
    Middleton, Blackford
    Sittig, Dean F.
    INTERNATIONAL JOURNAL OF MEDICAL INFORMATICS, 2012, 81 (11) : 733 - 745