Comparison of the mechanical properties of orthodontic nickel-titanium wires

被引:8
|
作者
Kayser, D [1 ]
Bourauel, C [1 ]
Braumann, B [1 ]
Jäger, A [1 ]
机构
[1] Univ Bonn, Poliklin Kieferorthapad, D-53111 Bonn, Germany
来源
BIOMEDIZINISCHE TECHNIK | 2002年 / 47卷 / 12期
关键词
nickel-titanium wire; orthodontics; super-elasticity; tooth movement;
D O I
10.1515/bmte.2002.47.12.334
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Two packages each, containing 10 wires per package, of different batches of 25 different types of orthodontic archwires made of super-elastic nickel-titanium alloys measuring 0.41 x 0.56 mm(2), were investigated. The wires were characterized by obtaining the following measurements at an ambient temperature of 37degrees: a three-point bending test with the supporting points spaced 10 mm apart, and determination of the torque/bending angle curves using a pure bending test. The force/deflection curves provided the parameters characterizing the super-elastic unloading plateau: average force, slope and endpoint. From the torque/bending angle curves, the parameters average torque, plateau endpoint and the elasticity parameters were determined. Average force (0.8-4.5 N), endpoint (0.2-0.9 mm) and the slope of the unloading plateau (0.2-2.1 N/mm) of the three-point bending test clearly differed for individual wires. Significant differences were also seen for average torque (1.5-11.5 Nmm), unloading plateau endpoint (2.7-20.0 degrees) and elasticity parameters epsilon(4), E-4, E-5 and E-6 in the pure bending test. Individual batches showed only minor differences. The results permit the conclusion to be drawn that super-elasticity is applicable to only a small portion of the wires examined. Although other wires showed super-elastic behaviour, the unloading plateaus has a force level of up to 6 N, and cannot be recommended for orthodontic application. The super-elastic plateau is often of use only for deflections greater than 1.5 mm. The use of super-elastic archwires made of nickel-titanium alloys makes sense only when the elastic properties of the respective wires are known. This makes the provision by the manufacturer of relevant data on the elastic properties of wires a necessity.
引用
收藏
页码:334 / 342
页数:9
相关论文
共 50 条
  • [31] A Comparative Evaluation of Surface Hardness and Nanomechanical Properties of Nickel-Titanium Orthodontic Wires: An In Vitro Study
    Santhakumari, Prasanth Prathapan
    Raja, Vighnesh Varma
    Kalarickal, Biju
    Parambil, Mohamed Haris Thavalam
    Sebastian, Joseph
    Cheeramelil, Jacob
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (07)
  • [32] A study of corrosion of stainless steel, nickel-titanium, coated nickel-titanium, and TMA orthodontic wires with potentiostatic anodic polarization.
    Kim, H
    Johnson, JW
    Ngan, P
    Durkee, M
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 278 - 278
  • [33] Characterization of nickel-titanium orthodontic wires by x-ray diffraction.
    Souza, ACRA
    Buono, VTL
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 181 - 181
  • [34] Mechanical behavior at different temperatures and stresses for superelastic nickel-titanium orthodontic wires having different transformation temperatures
    Iijima, M
    Ohno, H
    Kawashima, I
    Endo, K
    Mizoguchi, I
    DENTAL MATERIALS, 2002, 18 (01) : 88 - 93
  • [35] Comparison of the superelasticity of different nickel-titanium orthodontic archwires and the loss of their properties by heat treatment
    Bellini, Humberto
    Moyano, Javier
    Gil, Javier
    Puigdollers, Andreu
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2016, 27 (10)
  • [36] COMPARISONS OF THE THERMODYNAMIC PROPERTIES OF 3 NICKEL-TITANIUM ORTHODONTIC ARCHWIRES
    BISHARA, SE
    ORTHO, D
    WINTERBOTTOM, JM
    SULIEMAN, AHA
    RIM, K
    JAKOBSEN, JR
    ANGLE ORTHODONTIST, 1995, 65 (02) : 117 - 122
  • [37] Properties of Superelastic Nickel-Titanium Wires after Clinical Use
    Alcaraz, Ines
    Moyano, Javier
    Pamies, Ariadna
    Ruiz, Guillem
    Artes, Montserrat
    Gil, Javier
    Puigdollers, Andreu
    MATERIALS, 2023, 16 (16)
  • [38] The effect of temperature on the mechanical behavior of nickel-titanium orthodontic initial archwires
    Lombardo, Luca
    Toni, Giorgia
    Stefanoni, Filippo
    Mollica, Francesco
    Guarneri, Maria Paola
    Siciliani, Giuseppe
    ANGLE ORTHODONTIST, 2013, 83 (02) : 298 - 305
  • [39] Differential scanning calorimetry (DSC) analyses of superelastic and nonsuperelastic nickel-titanium orthodontic wires
    Bradley, TG
    Brantley, WA
    Culbertson, BM
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1996, 109 (06) : 589 - 597
  • [40] Characterization and coating stability evaluation of nickel-titanium orthodontic esthetic wires: an in vivo study
    Argalji, Nina
    da Silva, Eduardo Moreira
    Cury-Saramago, Adriana
    Mattos, Claudia Trindade
    BRAZILIAN ORAL RESEARCH, 2017, 31