Glucose-sensing electrode coated with polymer complex gel containing phenylboronic acid

被引:144
作者
Kikuchi, A
Suzuki, K
Okabayashi, O
Hoshino, H
Kataoka, K
Sakurai, Y
Okano, T
机构
[1] TOKYO WOMENS MED COLL,INST BIOMED ENGN,SHINJUKU KU,TOKYO 162,JAPAN
[2] TOKYO DENKI UNIV,FAC SCI & ENGN,DEPT APPL ELECTR ENGN,HATOYAMA,SAITAMA 35003,JAPAN
[3] SCI UNIV TOKYO,BIOSCI RES INST,NODA,CHIBA 278,JAPAN
关键词
D O I
10.1021/ac950748d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have prepared a copolymer containing both phenylboronic acid and tertiary amine moieties. The copolymer forms a stable complex with poly(vinyl alcohol) (PVA) since boronate moieties interact with PVA hydroxyl groups. The polymer-polymer complex changes its swelling degree with glucose concentration in Dulbecco's phosphate-buffered saline solution (PBS) at pH 7.4, due to the higher complex formation of boronic acid moieties with glucose hydroxyl groups over those in PVA. Glucose-responsive swelling changes of a membrane complex were then utilized to control glucose-responsive current changes with a membrane-coated platinum electrode. Glucose addition to PBS induces swelling of the cast gel membrane, leading to increased diffusion of ion species and thus increased measurable current changes. Since the addition of methyl a-D-glucoside has little influence on the current changes, the current change by the addition of glucose is indicative of the high selectivity of this system for glucose and its cis-hydroxyl groups in glucose, It is observed that current changes are proportional to glucose concentration in the range 0-300 mg/dL. This range corresponds well to physiological blood glucose levels. Current change rates determined from the slope of the time course immediately after glucose addition are also proportional to glucose concentration within this range, yielding even higher sensitivity to the change in glucose concentration, Reproducible signal output is also demonstrated by repetitive, stepwise glucose concentration changes. These results support the applicability of the platinum electrode coated with the gel membrane complex comprising a phenylboronic acid-containing polymer and PVA for a novel glucose-sensing device.
引用
收藏
页码:823 / 828
页数:6
相关论文
共 37 条
[1]   CLINICAL CONTROL OF DIABETES BY ARTIFICIAL PANCREAS [J].
ALBISSER, AM ;
LEIBEL, BS ;
EWART, TG ;
DAVIDOVAC, Z ;
BOTZ, CK ;
ZINGG, W ;
SCHIPPER, H ;
GANDER, R .
DIABETES, 1974, 23 (05) :397-404
[2]  
*AM CORP, 1981, BOR LIG BIOCH SEP AP
[3]   DESIGN AND INVITRO STUDIES OF A NEEDLE-TYPE GLUCOSE SENSOR FOR SUBCUTANEOUS MONITORING [J].
BINDRA, DS ;
ZHANG, YN ;
WILSON, GS ;
STERNBERG, R ;
THEVENOT, DR ;
MOATTI, D ;
REACH, G .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1692-1696
[4]   TEMPERATURE-INDUCED PHASE-TRANSITION BEHAVIORS OF RANDOM VS GRAFT-COPOLYMERS OF N-ISOPROPYLACRYLAMIDE AND ACRYLIC-ACID [J].
CHEN, GH ;
HOFFMAN, AS .
MACROMOLECULAR RAPID COMMUNICATIONS, 1995, 16 (03) :175-182
[5]   GRAFT-COPOLYMERS THAT EXHIBIT TEMPERATURE-INDUCED PHASE-TRANSITIONS OVER A WIDE-RANGE OF PH [J].
CHEN, GH ;
HOFFMAN, AS .
NATURE, 1995, 373 (6509) :49-52
[6]  
CLARK LC, 1988, T AM SOC ART INT ORG, V34, P259
[7]  
GOUGH DA, 1986, T AM SOC ART INT ORG, V32, P148
[8]   CHARACTERIZATION OF PERFLUOROSULFONIC ACID POLYMER COATED ENZYME ELECTRODES AND A MINIATURIZED INTEGRATED POTENTIOSTAT FOR GLUCOSE ANALYSIS IN WHOLE-BLOOD [J].
HARRISON, DJ ;
TURNER, RFB ;
BALTES, HP .
ANALYTICAL CHEMISTRY, 1988, 60 (19) :2002-2007
[9]  
*JAP BIOCH SOC, 1979, BIOCH DAT, V1, P1549
[10]   SENSITIVE GLUCOSE-INDUCED CHANGE OF THE LOWER CRITICAL SOLUTION TEMPERATURE OF POLY[N,N-DIMETHYLACRYLAMIDE-CO-3-(ACRYLAMIDO)PHENYL-BORONIC ACID] IN PHYSIOLOGICAL SALINE [J].
KATAOKA, K ;
MIYAZAKI, H ;
OKANO, T ;
SAKURAI, Y .
MACROMOLECULES, 1994, 27 (04) :1061-1062