Assessment of aortic stenosis by three-dimensional echocardiography: an accurate and novel approach

被引:67
作者
Goland, Sorel
Trento, Alfredo
Iida, Kiyoshi
Czer, Lawrence S. C.
De Robertis, Michele
Naqvi, Tasneem Z.
Tolstrup, Kirsten
Akima, Takashi
Luo, Huai
Siegel, Robert J.
机构
[1] Cedars Sinai Med Ctr, Div Cardiol, Dept Cardiol & Cardiothorac Surg, Los Angeles, CA 90048 USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Los Angeles, CA 90024 USA
关键词
D O I
10.1136/hrt.2006.110726
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Accurate assessment of aortic valve area (AVA) is important for clinical decision-making in patients with aortic valve stenosis (AS). The role of three-dimensional echocardiography (3D) in the quantitative assessment of AS has not been evaluated so far. Objectives: To evaluate the reproducibility and accuracy of real-time three-dimensional echocardiography (RT3D) and 3D-guided two-dimensional planimetry (3D/2D) for assessment of AS, and compare these results with those of standard echocardiography and cardiac catheterisation (Cath). Methods: AVA was estimated by transthoracic echo-Doppler (TTE) and by direct planimetry using transoesophageal echocardiography (TEE) as well as RT3D and 3D/2D. 15 patients underwent assessment of AS by Cath. Results: 33 patients with AS were studied (20 men, mean (SD) age 70 (14) years). Bland-Altman analysis showed good agreement and small absolute differences in AVA between all planimetric methods (RT3D vs 3D/2D: 20.01 (0.15) cm(2); 3D/2D vs TEE: 0.05 (0.22) cm(2); RT3D vs TEE: 0.06 (0.26) cm(2)). The agreement between AVA assessment by 2D-TTE and planimetry was 20.01 (0.20) cm(2) for 3D/2D; 0.00 (0.15) cm(2) for RT3D; and -0.05 (0.30) cm(2) for TEE. Correlation coefficient r for AVA assessment between each of 3D/2D, RT3D, TEE planimetry and Cath was 0.81, 0.86 and 0.71, respectively. The intraobserver variability was similar for all methods, but interobserver variability was better for 3D techniques than for TEE (p<0.05). Conclusions: The 3D echo methods for planimetry of the AVA showed good agreement with the standard TEE technique and flow-derived methods. Compared with AV planimetry by TEE, both 3D methods were at least as good as TEE and had better reproducibility. 3D aortic valve planimetry is a novel non-invasive technique, which provides an accurate and reliable quantitative assessment of AS.
引用
收藏
页码:801 / 807
页数:7
相关论文
共 29 条
  • [2] ACCURACY OF AORTIC-STENOSIS SEVERITY ASSESSMENT BY DOPPLER-ECHOCARDIOGRAPHY - IMPORTANCE OF IMAGE QUALITY
    BARTUNEK, J
    DEBACQUER, D
    RODRIGUES, AC
    DEBRUYNE, B
    [J]. INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1995, 11 (02): : 97 - 104
  • [3] Planimetry of aortic valve area using multiplane transoesophageal echocardiography is not a reliable method for assessing severity of aortic stenosis
    Bernard, Y
    Meneveau, N
    Vuillemenot, A
    Magnin, D
    Anguenot, T
    Schiele, F
    Bassand, JP
    [J]. HEART, 1997, 78 (01) : 68 - 73
  • [4] Improved assessment of mitral valve stenosis by volumetric real-time three-dimensional echocardiography
    Binder, TM
    Rosenhek, R
    Porenta, G
    Maurer, G
    Baumgartner, H
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (04) : 1355 - 1361
  • [5] Effect of harmonic imaging for planimetry on transthoracic echocardiography on visualization of the aortic valve
    Brasch, AV
    Luo, H
    Khan, SS
    Mirocha, JM
    DeRobertis, M
    Naqvi, TZ
    Jeon, DS
    Siegel, RJ
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (09) : 1047 - +
  • [6] Practical value of cardiac magnetic resonance imaging for clinical quantification of aortic valve stenosis comparison with echocardiography
    Caruthers, SD
    Lin, SJ
    Brown, P
    Watkins, MP
    Williams, TA
    Lehr, KA
    Wickline, SA
    [J]. CIRCULATION, 2003, 108 (18) : 2236 - 2243
  • [7] Value of multiplane transesophageal echocardiography in determining aortic valve area in aortic stenosis
    Cormier, B
    Iung, B
    Porte, JM
    Barbant, S
    Vahanian, A
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (10) : 882 - &
  • [8] FACTORS AFFECTING DOPPLER ECHOCARDIOGRAPHIC VALVE AREA ASSESSMENT IN AORTIC-STENOSIS
    DANIELSEN, R
    NORDREHAUG, JE
    VIKMO, H
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1989, 63 (15) : 1107 - 1111
  • [9] Planimetric assessment of anatomic valve area overestimates effective orifice area in bicuspid aortic stenosis
    Donal, E
    Novaro, GM
    Deserrano, D
    Popovic, ZB
    Greenberg, NL
    Richards, KE
    Thomas, JD
    Garcia, MJ
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2005, 18 (12) : 1392 - 1398
  • [10] Multislice computed tomography for detection of patients with aortic valve stenosis and quantification of severity
    Feuchtner, GM
    Dichtl, W
    Friedrich, GJ
    Frick, M
    Alber, H
    Schachner, T
    Bonatti, J
    Matlouhi, A
    Frede, T
    Pachinger, O
    Nedden, DZ
    Müller, S
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (07) : 1410 - 1417