Electrothermal atomic absorption spectrometric determination of lead in calcium drug samples by direct atomization technique

被引:18
作者
Ahsan, S [1 ]
Kaneco, S
Ohta, K
Mizuno, T
Suzuki, T
Miyada, M
Taniguchi, Y
机构
[1] Mie Univ, Fac Engn, Dept Chem Mat, Tsu, Mie 514, Japan
[2] Mie Univ, Environm Preservat Ctr, Tsu, Mie 514, Japan
[3] Mie Ind Res Inst, Tsu, Mie 514, Japan
关键词
lead; direct atomization; drug sample; electrothermal atomization; molybdenum tube atomizer;
D O I
10.1016/S0003-2670(98)00067-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The direct determination of lead in calcium drug samples by electrothermal atomic absorption spectrometry (ETAAS) with a molybdenum tube atomizer has been developed. Direct calibration with lead standard solutions together with matrix elements (CaHPO4 or CaCo3) and ultrasonic agitation of a solution including the sample powder were used. Thiourea served as a matrix modifier to eliminate the interference of matrix elements. Analytical results obtained from four calcium drug samples by direct atomization are in good conformity with the dissolved acid digested samples. Advantages of this method are simplicity, rapid calibration, fast analysis and low cost. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:279 / 284
页数:6
相关论文
共 50 条
[31]   DIRECT DETERMINATION OF MANGANESE IN BIOLOGICAL-MATERIALS USING ELECTROTHERMAL ATOMIZATION ATOMIC-ABSORPTION SPECTROMETRY WITH A MOLYBDENUM TUBE ATOMIZER [J].
OHTA, K ;
ITOH, S ;
KANECO, S ;
MIZUNO, T .
ANALYTICAL SCIENCES, 1992, 8 (03) :423-426
[32]   Electrothermal atomic absorption spectrometric determination of cadmium and lead in traces in aquatic systems following flotation by two chromium(III) collectors [J].
Kormusoska, Natasa Bakreska ;
Cundeva, Katarina ;
Stafilov, Trajce .
JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2009, 44 (12) :1274-1281
[33]   MODEL FOR THE ANALYTICAL SIGNAL IN ATOMIC ABSORPTION SPECTROMETRY WITH ELECTROTHERMAL ATOMIZATION [J].
Rogulsky, Yu. V. ;
Buhay, A. N. ;
Gudakova, A. A. ;
Kulik, A. N. .
JOURNAL OF APPLIED SPECTROSCOPY, 2008, 75 (03) :309-313
[34]   Model for the analytical signal in atomic absorption spectrometry with electrothermal atomization [J].
Yu. V. Rogulsky ;
A. N. Buhay ;
A. A. Gudakova ;
A. N. Kulik .
Journal of Applied Spectroscopy, 2008, 75 :309-313
[35]   Feasibility of using direct determination of cadmium and lead in fresh meat by electrothermal atomic absorption spectrometry for screening purposes [J].
Damin, Isabel C. F. ;
Silva, Marcia M. ;
Vale, Maria Goreti R. ;
Welz, Bemhard .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (09) :1037-1045
[36]   SAMPLE PREPARATION PROCEDURES FOR VANADIUM DETERMINATION IN PETROLEUM BY ATOMIC-ABSORPTION SPECTROMETRY WITH ELECTROTHERMAL ATOMIZATION [J].
BARRERA, PB ;
CALVO, CP ;
MARTINEZ, FB .
ANALYTICAL LETTERS, 1991, 24 (03) :447-458
[37]   ROMAN SPECTROMETRIC STUDY OF THE CHARRING PROCESS OF LEAD IN SULFUR IN ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
KOSHINO, Y ;
NARUKAWA, A .
ANALYST, 1994, 119 (11) :2473-2475
[38]   Empirical modelling of interferences in electrothermal atomization atomic absorption spectrometry [J].
Grotti, M ;
Leardi, R ;
Frache, R .
ANALYTICA CHIMICA ACTA, 1998, 376 (03) :293-304
[39]   Cyanide as a releasing agent in atomic absorption spectrometric determination of lead and cadmium [J].
ElDefrawy, MM ;
Kabil, MA ;
Khalifa, MI ;
Othman, AS .
ANALUSIS, 1995, 23 (10) :507-510
[40]   Cloud point extraction procedure for flame atomic absorption spectrometric determination of lead(II) in sediment and water samples [J].
Surme, Yavuz ;
Narin, Ibrahim ;
Soylak, Mustafa ;
Yuruk, Huseyin ;
Dogan, Mehmet .
MICROCHIMICA ACTA, 2007, 157 (3-4) :193-199