Comparative biomechanical analysis of an improved novel pedicle screw with sheath and bone cement

被引:22
作者
Takigawa, Tomoyuki
Tanaka, Masato
Konishi, Hitoshi
Ikuma, Hisanori
Misawa, Haruo
Sugimoto, Yoshihisa
Nakanishi, Kazuo
Kuramoto, Koichi
Nishida, Keiichiro
Ozaki, Toshifumi
机构
[1] Okayama Univ, Grad Sch Med Dent Pharmaceut Sci, Dept Orthopaed, Okayama 7008558, Japan
[2] Okayama Senoo Hosp, Dept Orthopaed Surg, Okayama, Japan
[3] Nakashima Propeller Co Ltd, Nakashima Med Div, Okayama, Japan
来源
JOURNAL OF SPINAL DISORDERS & TECHNIQUES | 2007年 / 20卷 / 06期
关键词
pedicle screw; biomechanics; osteoporosis; polymethylmethacrylate augmentation;
D O I
10.1097/BSD.0b013e318030d2d6
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design: A human cadaveric biomechanical study of fixation strength of an improved novel pedicle screw (NPS) with cement and a conventional screw. Objective: To clarify whether the NPS has adequate fixation strength without leakage in vertebrae with low bone quality. Summary of Background Data: The fixation strength of pedicle screws decreases in frail spines of elderly osteoporotic patients. Augmentation of screw fixation with bone cement must be balanced against increased difficulty of screw removal and risk of cement leakage. We developed the NPS consisting of an internal screw and an outer sheath to mitigate the disadvantages of cement augmentation. Methods: The T12 and L1 vertebrae obtained from 18 formalin preserved cadavers (11 males and 7 females; mean age, 82.7y) were used. The mean bone mineral density was 0.39 +/- 0.14 g/cm(2). The NPS was inserted into one pedicle of each vertebra and the control screw, a Compact CD2 screw, was inserted into the contralateral pedicle. Both screws were 6 mm in diameter and 40 mm in length. Pull-out tests were performed at a crosshead speed of 10 mm/min. Cyclic loading tests were performed with a maximum 250 N load at 2 Hz until 30,000 cycles. Results: Cement leakage did not occur in any of the specimens tested. The mean maximum force at pull-out was 760 +/- 344 N for the NPS and 346 172 N for the control screw (P < 0.01). Loosening of 50% of the screws was observed after 17,000 cycles of the NPS and after 30 cycles of the control screw. The hazard ratio of loosening was 19.6 (95% confidence interval 19.3-19.9) (P < 0.001). Conclusions: The NPS showed a significantly higher mechanical strength than the control screw in both pull-out tests and cyclic loading test than the control screw in both pull-out tests and cyclic loading test. The NPS showed more than adequate strength without cement leakage.
引用
收藏
页码:462 / 467
页数:6
相关论文
共 35 条
[1]  
Abshire B B, 2001, Spine J, V1, P408, DOI 10.1016/S1529-9430(01)00119-X
[2]   MECHANICAL-PROPERTIES OF MICROCALLUS IN HUMAN CANCELLOUS BONE [J].
BLACKBURN, J ;
HODGSKINSON, R ;
CURREY, JD ;
MASON, JE .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1992, 10 (02) :237-246
[3]  
Cook Stephen D, 2004, Spine J, V4, P402, DOI 10.1016/j.spinee.2003.11.010
[4]   LOADS ON THE LUMBAR TRUNK DURING LEVEL WALKING [J].
CROMWELL, R ;
SCHULTZ, AB ;
BECK, R ;
WARWICK, D .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1989, 7 (03) :371-377
[5]   EFFECT OF FORMALDEHYDE FIXATION ON SOME MECHANICAL-PROPERTIES OF BOVINE BONE [J].
CURREY, JD ;
BREAR, K ;
ZIOUPOS, P ;
REILLY, GC .
BIOMATERIALS, 1995, 16 (16) :1267-1271
[6]   Spatial relationships between prevalent and incident spine fractures [J].
Davis, JW ;
Grove, JS ;
Wasnich, RD ;
Ross, PD .
BONE, 1999, 24 (03) :261-264
[7]   FORMALIN FIXATION EFFECTS ON VERTEBRAL BONE-DENSITY AND FAILURE MECHANICS - AN IN-VITRO STUDY OF HUMAN AND SHEEP VERTEBRAE [J].
EDMONDSTON, SJ ;
SINGER, KP ;
DAY, RE ;
BREIDAHL, PD ;
PRICE, RI .
CLINICAL BIOMECHANICS, 1994, 9 (03) :175-179
[8]   Bone cement or bone substitute augmentation of pedicle screws improves pullout strength in posterior spinal fixation [J].
Evans, SL ;
Hunt, CM ;
Ahuja, S .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2002, 13 (12) :1143-1145
[9]   Incidence of subsequent vertebral fracture after kyphoplasty [J].
Fribourg, D ;
Tang, C ;
Delamarter, R ;
Bae, H .
SPINE, 2004, 29 (20) :2270-2276
[10]   VERTEBRAL FRACTURE ASSESSMENT USING A SEMIQUANTITATIVE TECHNIQUE [J].
GENANT, HK ;
WU, CY ;
VANKUIJK, C ;
NEVITT, MC .
JOURNAL OF BONE AND MINERAL RESEARCH, 1993, 8 (09) :1137-1148