Comprehensive investigation of three-dimensional diffuse optical tomography with depth compensation algorithm

被引:40
作者
Niu, Haijing
Lin, Zi-Jing
Tian, Fenghua
Dhamne, Sameer
Liu, Hanli [1 ]
机构
[1] Univ Texas Arlington, Dept Bioengn, Arlington, TX 76019 USA
关键词
diffuse optical tomography; spatial resolution; depth localization; brain imaging; NEAR-INFRARED TOMOGRAPHY; FREQUENCY-DOMAIN; BRAIN ACTIVATION; BREAST; RECONSTRUCTION; RESOLUTION; LOCALIZATION; SENSITIVITY; HEMOGLOBIN; SIMULATION;
D O I
10.1117/1.3462986
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A depth compensation algorithm (DCA) can effectively improve the depth localization of diffuse optical tomography (DOT) by compensating the exponentially decreased sensitivity in the deep tissue. In this study, DCA is investigated based on computer simulations, tissue phantom experiments, and human brain imaging. The simulations show that DCA can largely improve the spatial resolution of DOT in addition to the depth localization, and DCA is also effective for multispectral DOT with a wide range of optical properties in the background tissue. The laboratory phantom experiment demonstrates that DCA can effectively differentiate two embedded objects at different depths in the medium. DCA is further validated by human brain imaging using a finger-tapping task. To our knowledge, this is the first demonstration to show that DCA is capable of accurately localizing cortical activations in the human brain in three dimensions. (C) 2010 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3462986]
引用
收藏
页数:9
相关论文
共 31 条
[1]   Optical tomography in medical imaging [J].
Arridge, SR .
INVERSE PROBLEMS, 1999, 15 (02) :R41-R93
[2]   MRI-guided optical tomography: Prospects and computation for a new imaging method [J].
Barbour, RL ;
Graber, HL ;
Chang, JW ;
Barbour, SLS ;
Koo, PC ;
Aronson, R .
IEEE COMPUTATIONAL SCIENCE & ENGINEERING, 1995, 2 (04) :63-77
[3]   Simulation study of magnetic resonance imaging-guided cortically constrained diffuse optical tomography of human brain function [J].
Boas, DA ;
Dale, AM .
APPLIED OPTICS, 2005, 44 (10) :1957-1968
[4]   Diffuse optical imaging of brain activation: approaches to optimizing image sensitivity, resolution, and accuracy [J].
Boas, DA ;
Dale, AM ;
Franceschini, MA .
NEUROIMAGE, 2004, 23 :S275-S288
[5]   Improving the diffuse optical imaging spatial resolution of the cerebral hemodynamic response to brain activation in humans [J].
Boas, DA ;
Chen, K ;
Grebert, D ;
Franceschini, MA .
OPTICS LETTERS, 2004, 29 (13) :1506-1508
[6]   Three dimensional Monte Carlo code for photon migration through complex heterogeneous media including the adult human head [J].
Boas, DA ;
Culver, JP ;
Stott, JJ ;
Dunn, AK .
OPTICS EXPRESS, 2002, 10 (03) :159-170
[7]   Portable near-infrared diffusive light imager for breast cancer detection [J].
Chen, NG ;
Huang, MM ;
Xia, HJ ;
Piao, DQ ;
Cronin, E ;
Zhu, Q .
JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (03) :504-510
[8]   Diffuse optical tomography of cerebral blood flow, oxygenation, and metabolism in rat during focal ischemia [J].
Culver, JP ;
Durduran, T ;
Furuya, T ;
Cheung, C ;
Greenberg, JH ;
Yodh, AG .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2003, 23 (08) :911-924
[9]   Three-dimensional optical tomography: resolution in small-object imaging [J].
Dehghani, H ;
Pogue, BW ;
Jiang, SD ;
Brooksby, B ;
Paulsen, KD .
APPLIED OPTICS, 2003, 42 (16) :3117-3128
[10]   The effects of internal refractive index variation in near-infrared optical tomography: a finite element modelling approach [J].
Dehghani, H ;
Brooksby, B ;
Vishwanath, K ;
Pogue, BW ;
Paulsen, KD .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (16) :2713-2727