Purification of a primary coolant in a nuclear power plant using a magnetic filter - electrodeionization hybrid separation system

被引:18
作者
Song, JH
Song, MC
Yeon, KH
Kim, JB
Lee, KJ
Moon, SH
机构
[1] Gwangju Inst Sci & Technol, Dept Environm Sci & Engn, Kwangju 500712, South Korea
[2] Korea Adv Inst Sci & Technol, Dept Nucl & Quantum Engn, Taejon 305701, South Korea
关键词
D O I
10.1007/s10967-004-0500-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A magnetic filter-continuous electrodeionization (CEDI) hybrid separation system was investigated for the purification of the primary coolant in a nuclear power plant. A magnetic filter system with a 3000 Gauss magnetic field and a CEDI system with a cell consisting of 3 compartments were used for the removal of magnetite and nickel ions, respectively. The hybrid separation system achieved removal rates of 98% for magnetite and 99% for the nickel ions demonstrating its feasibility for the purification of primary coolant.
引用
收藏
页码:725 / 732
页数:8
相关论文
共 50 条
  • [21] Reliability of the Coolant Flow Rate Measuring System at the Ignalina Nuclear Power Plant
    Yu. Augutis
    E. Uspuras
    R. Alzbutas
    V. Matuzas
    Atomic Energy, 2004, 96 : 403 - 406
  • [22] Reliability of the coolant flow rate measuring system at the Ignalina nuclear power plant
    Augutis, Y
    Uspuras, E
    Alzbutas, R
    Matuzas, V
    ATOMIC ENERGY, 2004, 96 (06) : 403 - 406
  • [23] Research on Evaluation Method of Actinide Nuclide Activities in Primary Coolant System of Pressurized Water Reactor Nuclear Power Plant
    Xiong J.
    Lyu W.
    Guo R.
    Gao Y.
    Jiang Z.
    Hedongli Gongcheng/Nuclear Power Engineering, 2024, 45 (02): : 47 - 52
  • [24] Simulation and Analysis of Reactor Coolant System for Two-Loop Nuclear Power Plant
    Zeng C.
    Zhao Y.
    Ye Z.
    Ren Y.
    Hedongli Gongcheng/Nuclear Power Engineering, 2018, 39 : 58 - 61
  • [25] Distributed Raman temperature measurement system for monitoring of nuclear power plant coolant loops
    Jensen, F
    Takada, E
    Nakazawa, M
    Kakuta, T
    Yamamoto, S
    FIBER OPTIC SENSORS V, 1996, 2895 : 132 - 143
  • [26] The development of reactor coolant pump vibration monitoring and a diagnostic system in the nuclear power plant
    Koo, IS
    Kim, WW
    ISA TRANSACTIONS, 2000, 39 (03) : 309 - 316
  • [27] Basic Properties and Numerical Simulations of the Radioactive Noble Gas Removal System from the Primary Coolant in PWR Nuclear Power Plant
    Kamishima, Naoyuki
    Nishio, Hiroki
    Nishimoto, Shohei
    Miyamoto, Hitoshi
    Minemoto, Masaki
    KAGAKU KOGAKU RONBUNSHU, 2011, 37 (05) : 400 - 407
  • [28] Xenon isotopic signature study of the primary coolant of CANDU nuclear power plant to enhance CTBT verification
    Zhang, W.
    Ungar, K.
    Hoffman, I.
    Lawrie, R.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2009, 280 (01) : 121 - 128
  • [29] Xenon isotopic signature study of the primary coolant of CANDU nuclear power plant to enhance CTBT verification
    W. Zhang
    K. Ungar
    I. Hoffman
    R. Lawrie
    Journal of Radioanalytical and Nuclear Chemistry, 2009, 280 : 121 - 128