Axial compression behavior of precast circular semi-continuous concrete-filled steel tube columns

被引:2
|
作者
Cao, Bing [1 ]
Xie, Mingming [1 ]
Zhu, Longfei [1 ]
Cao, Wancheng [1 ]
Huang, Bo [1 ]
Du, Yihan [1 ]
Wang, Jiawei [1 ]
Yang, Yizhen [1 ]
Wang, Changsheng [1 ]
机构
[1] Anhui Polytech Univ, Coll Civil Engn & Architecture, Beijing Rd 8, Wuhu 241000, Peoples R China
关键词
Precast circular semi-continuous concrete-filled steel tube (PCSCFST) column; confinement; bolt; axial compression; ultimate bearing capacity; SEISMIC BEHAVIOR; PSEUDODYNAMIC TESTS; TURKEY EARTHQUAKE; AUGUST; 17; CONNECTIONS; STRENGTH; PERFORMANCE; BUILDINGS; KOCAELI; MEMBERS;
D O I
10.1177/16878132221107471
中图分类号
O414.1 [热力学];
学科分类号
摘要
To study the axial compression performance of precast circular semi-continuous concrete-filled steel tube (PCSCFST) column, a total of 17 specimens were prepared and tested, including 13 PCSCFST columns and 4 continuous CFST columns. This PCSCFST column is made up of upper and lower steel tubes and outer steel tubes connected by bolts, which has the advantages of easy factory production and convenient transportation. The results showed that shear failure occurred in continuous CFST columns, but not in PCSCFST columns, bolts had obvious influence on failure mode. Maintaining the consistency of the thickness of each steel tube on the specimen can not only improve the local buckling, but also avoid the short plate effect to give full play to the material performance. Moreover, with the increase of steel tube thickness, concrete strength, bolt diameter, reduction of specimen length and pure bolt connection instead of bolt and weld combination connection, the deformation resistance of bolts and axial compression performance of specimens had been enhanced. However, the increase of bolt diameter from 12 to 18 mm resulted in a better strength degradation rate, but worse bearing capacity and deformation resistance. Finally, the predictions of the ultimate bearing capacity of PCSCFST columns under axial compression agree well with the test results, the average value of N-exp/N-pre and the variance are 0.998 and 0.00111.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Nonlinear inelastic analysis of semi-rigid steel frames with circular concrete-filled steel tubular columns
    Bui, Van-Tuong
    Kim, Seung-Eock
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2021, 196
  • [42] Axial Strength of Concrete-Filled Square Steel Tubular Columns Reinforced by Inner Circular Steel Tube
    Li, Xinzhong
    Wei, Xueying
    Zhao, Junhai
    ADVANCES IN STRUCTURES, PTS 1-5, 2011, 163-167 : 4542 - 4545
  • [43] Axial compressive behavior of reinforced concrete-filled stainless steel tube (RCFSST) stub columns: Experimental research
    Qiao, Qiyun
    Li, Jiafeng
    Mou, Ben
    Cao, Wanlin
    JOURNAL OF BUILDING ENGINEERING, 2021, 44
  • [44] Stress-strain modelling of circular concrete-filled FRP-steel composite tube columns under axial compression load
    Hamed, Asmaa Y.
    Hassanein, M. F.
    Hasan, Mohamed Abdel-Shakour
    STRUCTURES, 2024, 67
  • [45] SEISMIC BEHAVIOR OF PRECAST CONCRETE FILLED DUAL STEEL TUBE COLUMNS IN SOCKET FOUNDATIONS
    Li, Xian
    Ma, Xiao-han
    Ding, Bei-Dou
    Zhao, Yu-wei
    Zhang, Peng
    ADVANCED STEEL CONSTRUCTION, 2019, 15 (03): : 215 - 224
  • [46] Eccentric compression behavior of concrete-filled steel tube columns strengthened by CFRP/steel strip
    Miao, Kunting
    Wei, Yang
    Zhang, Shichang
    Zheng, Kaiqi
    Ding, Mingmin
    ENGINEERING STRUCTURES, 2023, 287
  • [47] Iterative Finite Element Analysis of Concrete-Filled Steel Tube Columns Subjected to Axial Compression
    Sarir, Payam
    Jiang, Huanjun
    Asteris, Panagiotis G.
    Formisano, Antonio
    Armaghani, Danial Jahed
    BUILDINGS, 2022, 12 (12)
  • [48] Axial behaviour of slender concrete-filled steel tube square columns strengthened with square concrete-filled steel tube jackets
    Zhu, Tao
    Liang, Hongjun
    Lu, Yiyan
    Li, Weijie
    Zhang, Hong
    ADVANCES IN STRUCTURAL ENGINEERING, 2020, 23 (06) : 1074 - 1086
  • [49] Fire Resistance of Crisscross Concrete-Filled Steel Tube Core Columns in the Different Axial Compression
    Xu, Yafeng
    Fu, Yi
    Zhang, Yubo
    Zhao, Xin
    ADVANCES IN STRUCTURES, PTS 1-5, 2011, 163-167 : 157 - 160
  • [50] Experiments and design of laminated bamboo and concrete-filled steel tube columns under axial compression
    Zhang, Zicheng
    Wei, Yang
    Yi, Jiyang
    Wei, Baoxing
    Lin, Yu
    Huang, Silu
    ENGINEERING STRUCTURES, 2024, 318