Transformer winding condition assessment using frequency response analysis and evidential reasoning

被引:59
|
作者
Shintemirov, A. [1 ]
Tang, W. H. [1 ]
Wu, Q. H. [1 ]
机构
[1] Univ Liverpool, Dept Elect Engn & Elect, Liverpool L69 3GJ, Merseyside, England
关键词
DECISION-ANALYSIS; FAULT-DIAGNOSIS; ALGORITHM; FRA;
D O I
10.1049/iet-epa.2009.0102
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The study presents an evidential reasoning (ER) approach to transformer winding assessment based on frequency response analysis (FRA). A conventional FRA assessment process is firstly discussed, where frequency response comparison methods and interpretation features are briefly introduced. Then an FRA assessment process is transferred into a multiple-attribute decision-making (MADM) problem under an ER framework and an introduction to the ER algorithm is given. Subsequently, several examples of transformer winding condition assessment problems are considered using two ER evaluation analysis models, where the potential of the ER approach in combining evidence and dealing with uncertainties is demonstrated. In the case when more than one expert is involved in an FRA assessment process, the developed ER framework can be used to aggregate experts' subjective judgements and produce an overall evaluation of the condition of a transformer winding in a formalised form.
引用
收藏
页码:198 / 212
页数:15
相关论文
共 50 条
  • [31] Locating Inter-disc Faults in Transformer Winding Using Frequency Response Analysis
    Yousof, M. F. M.
    Ekanayake, C.
    Saha, T. K.
    2013 AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC), 2013,
  • [32] Novel method for detection of transformer winding faults using Sweep Frequency Response Analysis
    Singh, Jashandeep
    Sood, Yog Raj
    Verma, Piush
    Jarial, Raj Kumar
    2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 2949 - +
  • [33] Transformer winding frequency response data analysis with block frequency point method
    China Electric Power Research Institute, Beijing 100192, China
    Xu, Y. (xuyuan@epri.sgcc.com.cn), 1600, Automation of Electric Power Systems Press (38):
  • [34] Condition assessment for bridges: a hierarchical evidential reasoning (HER) framework
    Bolar, Aman
    Tesfamariam, Solomon
    Sadiq, Rehan
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2013, 9 (07) : 648 - 666
  • [35] Condition assessment model for sewer pipelines using fuzzy-based evidential reasoning
    Hawari, Alaa
    Alkadour, Firas
    Elmasry, Mohamed
    Zayed, Tarek
    AUSTRALIAN JOURNAL OF CIVIL ENGINEERING, 2018, 16 (01) : 23 - 37
  • [36] Frequency response analysis approach for condition monitoring of transformer
    Nirgude, PM
    Gunasekaran, B
    Channakeshava
    Rajkumar, AD
    Singh, BP
    2004 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2004, : 186 - 189
  • [37] POWER TRANSFORMER HEALTH INDEX ESTIMATION USING EVIDENTIAL REASONING
    Milosavljevic, Srdjan
    Janjic, Aleksandar
    FACTA UNIVERSITATIS-SERIES ELECTRONICS AND ENERGETICS, 2020, 33 (04) : 571 - 581
  • [38] Deformation Study of a Transformer Winding using Frequency-Response Analysis and Finite-Element Analysis
    Pradhan, Sibabrata
    Nayak, Sisir Kumar
    2022 22ND NATIONAL POWER SYSTEMS CONFERENCE, NPSC, 2022,
  • [39] Frequency response analysis in diagnosing transformer winding movements - Fundamental understandings
    Sofian, DM
    Wang, ZD
    Jayasinghe, SB
    UPEC 2004: 39th International Universitities Power Engineering Conference, Vols 1-3, Conference Proceedings, 2005, : 138 - 142
  • [40] Influence of Temperature and Moisture Content on Frequency Response Analysis of Transformer Winding
    Bagheri, Mehdi
    Phung, B. T.
    Blackburn, Trevor
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (03) : 1393 - 1404