An epistemic indoor air quality assessment protocol for air-conditioned offices

被引:15
|
作者
Hui, P. S. [1 ]
Wong, L. T. [1 ]
Mui, K. W. [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
关键词
IAQ; epistemic assessment; CO2; measurements; air-conditioned offices;
D O I
10.1177/1420326X07076503
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Long-term measurement could be the best approach to determine the average pollutant concentration of an indoor environment for decisions on mitigation measures. This approach requires considerable measurement effort for accurate results and hence indoor air quality (IAQ) assessment methods that need less effort have been cleveloped.This study proposes an epistemic approach for assessing an acceptable office IAQ against certain indoor air pollutant exposure limits. Together with the prior understanding of failure rates of IAQ determined from a number of extensive survey studies, a sample test result of pollutant levels and the uncertainties of different sampling schemes, the probability of satisfactory IAQ for an assessed air-conditioned office could be quantified. In particular, assessment of an acceptable IAQ for some air-conditioned offices in Hong Kong was demonstrated by taking CO2 as an example pollutant. Accuracy of the failure rates was improved by the application of sampling correction factors and Bayesian statistics. The probabilities of an acceptable office IAQ were evaluated against a CO2 level limit. This approach would be useful for IAQ assessment in some air-conditioned offices.
引用
收藏
页码:139 / 147
页数:9
相关论文
共 50 条
  • [21] Performance by Design: Supporting Decisions around Indoor Air Quality in Offices
    Snow, Stephen
    Oakley, Michael
    Schraefel, M. C.
    PROCEEDINGS OF THE 2019 ACM DESIGNING INTERACTIVE SYSTEMS CONFERENCE (DIS 2019), 2019, : 99 - 111
  • [22] Indoor air quality index for preoccupancy assessment
    Wagdi, Dalia
    Tarabieh, Khaled
    Abou Zeid, Mohamed Nagib
    AIR QUALITY ATMOSPHERE AND HEALTH, 2018, 11 (04) : 445 - 458
  • [23] Indoor air quality index for preoccupancy assessment
    Dalia Wagdi
    Khaled Tarabieh
    Mohamed Nagib Abou Zeid
    Air Quality, Atmosphere & Health, 2018, 11 : 445 - 458
  • [24] Indoor air quality assessment in the air traffic control tower of the Athens Airport, Greece
    Helmis, Costas G.
    Assimakopoulos, Vasiliki D.
    Flocas, Helena A.
    Stathopoulou, Ourania I.
    Sgouros, George
    Hatzaki, Maria
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2009, 148 (1-4) : 47 - 60
  • [25] Ventilation of air-conditioned residential buildings: A case study in Hong Kong
    Ai, Z. T.
    Mak, C. M.
    Cui, D. J.
    Xue, P.
    ENERGY AND BUILDINGS, 2016, 127 : 116 - 127
  • [26] Indoor air quality in sports center: Assessment of gaseous pollutants
    Bralewska, Karolina
    Rogula-Kozlowska, Wioletta
    Bralewski, Adrian
    BUILDING AND ENVIRONMENT, 2022, 208
  • [27] Assessment of indoor air quality in geriatric environments of southwestern Europe
    Pereira, Ermelinda L.
    Madacussengua, Obete
    Baptista, Paula
    Feliciano, Manuel
    AEROBIOLOGIA, 2021, 37 (01) : 139 - 153
  • [28] MODELING OF INDOOR AIR QUALITY
    Teodosiu, Catalin
    Ilie, Viorel
    Teodosiu, Raluca
    ENERGY AND CLEAN TECHNOLOGIES, 2015, : 969 - 976
  • [29] Indoor air quality in schools
    de Gennaro, Gianluigi
    Dambruoso, Paolo Rosario
    Loiotile, Annamaria Demarinis
    Di Gilio, Alessia
    Giungato, Pasquale
    Tutino, Maria
    Marzocca, Annalisa
    Mazzone, Antonio
    Palmisani, Jolanda
    Porcelli, Francesca
    ENVIRONMENTAL CHEMISTRY LETTERS, 2014, 12 (04) : 467 - 482
  • [30] Assessment of indoor air quality in geriatric environments of southwestern Europe
    Ermelinda L. Pereira
    Obete Madacussengua
    Paula Baptista
    Manuel Feliciano
    Aerobiologia, 2021, 37 : 139 - 153