An epistemic indoor air quality assessment protocol for air-conditioned offices

被引:15
|
作者
Hui, P. S. [1 ]
Wong, L. T. [1 ]
Mui, K. W. [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
关键词
IAQ; epistemic assessment; CO2; measurements; air-conditioned offices;
D O I
10.1177/1420326X07076503
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Long-term measurement could be the best approach to determine the average pollutant concentration of an indoor environment for decisions on mitigation measures. This approach requires considerable measurement effort for accurate results and hence indoor air quality (IAQ) assessment methods that need less effort have been cleveloped.This study proposes an epistemic approach for assessing an acceptable office IAQ against certain indoor air pollutant exposure limits. Together with the prior understanding of failure rates of IAQ determined from a number of extensive survey studies, a sample test result of pollutant levels and the uncertainties of different sampling schemes, the probability of satisfactory IAQ for an assessed air-conditioned office could be quantified. In particular, assessment of an acceptable IAQ for some air-conditioned offices in Hong Kong was demonstrated by taking CO2 as an example pollutant. Accuracy of the failure rates was improved by the application of sampling correction factors and Bayesian statistics. The probabilities of an acceptable office IAQ were evaluated against a CO2 level limit. This approach would be useful for IAQ assessment in some air-conditioned offices.
引用
收藏
页码:139 / 147
页数:9
相关论文
共 50 条
  • [11] A statistical model for characterizing common air pollutants in air-conditioned offices
    Wong, L. T.
    Mui, K. W.
    Hui, P. S.
    ATMOSPHERIC ENVIRONMENT, 2006, 40 (23) : 4246 - 4257
  • [12] Comparison of Indoor Air Quality for Air-Conditioned and Naturally Ventilated Office Spaces in Urban Area
    Jain, Supreme
    Garg, Divyam
    Goel, Anubha
    INDOOR ENVIRONMENTAL QUALITY, ACIEQ, 2020, 60 : 1 - 8
  • [13] Feasibility study of a simple IAQ index for assessing air-conditioned offices
    Hui, P. S.
    Mui, K. W.
    Wong, L. T.
    FACILITIES, 2012, 30 (3-4) : 124 - 134
  • [14] An energy benchmarking model for ventilation systems of air-conditioned offices in subtropical climates
    Mui, K. W.
    Wong, L. T.
    Law, L. Y.
    APPLIED ENERGY, 2007, 84 (01) : 89 - 98
  • [15] Risks of unsatisfactory airborne bacteria level in air-conditioned offices of subtropical climates
    Mui, K. W.
    Wong, L. T.
    Hui, P. S.
    BUILDING AND ENVIRONMENT, 2008, 43 (04) : 475 - 479
  • [16] Impact of condensate cooled air purging on indoor air quality in an air conditioned laboratory
    Palanisamy, Dhamodharan
    Ayalur, Bakthavatsalam Kannappan
    BUILDING AND ENVIRONMENT, 2021, 188
  • [17] INDOOR AIR QUALITY IN SMALL DOCTOR'S OFFICES IN POLAND
    Gladyszewska-Fiedoruk, Katarzyna
    Krawczyk, Dorota Anna
    SUSTAINABLE BUILDING AND REFURBISHMENT FOR NEXT GENERATIONS, 2013, : 543 - 546
  • [18] Assessment of productivity loss in air-conditioned buildings using PMV index
    Kosonen, R
    Tan, F
    ENERGY AND BUILDINGS, 2004, 36 (10) : 987 - 993
  • [19] Imposing limits on summer set-points in UK air-conditioned offices: A survey of facility managers
    Lakeridou, Michelle
    Ucci, Marcella
    Marmot, Alexi
    ENERGY POLICY, 2014, 75 : 354 - 368
  • [20] Investigation of Indoor Air Quality in Several Offices in Baghdad - Case Study
    Al Rikabi, Ihab Jabbar
    Abuelnour, Mohamed Ali
    Abed, Talib Kamil
    Jawad, Abdul Hameed Mohammed
    Omara, Adil A. M.
    2022 8TH INTERNATIONAL ENGINEERING CONFERENCE ON SUSTAINABLE TECHNOLOGY AND DEVELOPMENT (IEC), 2022, : 78 - 82