An epistemic indoor air quality assessment protocol for air-conditioned offices

被引:15
作者
Hui, P. S. [1 ]
Wong, L. T. [1 ]
Mui, K. W. [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
关键词
IAQ; epistemic assessment; CO2; measurements; air-conditioned offices;
D O I
10.1177/1420326X07076503
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Long-term measurement could be the best approach to determine the average pollutant concentration of an indoor environment for decisions on mitigation measures. This approach requires considerable measurement effort for accurate results and hence indoor air quality (IAQ) assessment methods that need less effort have been cleveloped.This study proposes an epistemic approach for assessing an acceptable office IAQ against certain indoor air pollutant exposure limits. Together with the prior understanding of failure rates of IAQ determined from a number of extensive survey studies, a sample test result of pollutant levels and the uncertainties of different sampling schemes, the probability of satisfactory IAQ for an assessed air-conditioned office could be quantified. In particular, assessment of an acceptable IAQ for some air-conditioned offices in Hong Kong was demonstrated by taking CO2 as an example pollutant. Accuracy of the failure rates was improved by the application of sampling correction factors and Bayesian statistics. The probabilities of an acceptable office IAQ were evaluated against a CO2 level limit. This approach would be useful for IAQ assessment in some air-conditioned offices.
引用
收藏
页码:139 / 147
页数:9
相关论文
共 38 条
[11]  
*HKEPD, 1997, FIN REP CONS STUD IN
[12]   Health effects due to indoor air pollution [J].
Hoskins, JA .
INDOOR AND BUILT ENVIRONMENT, 2003, 12 (06) :427-433
[13]   Sampling point densities for assessing indoor air quality [J].
Hui, PS ;
Wong, LT ;
Mui, KW .
Tall Buildings: From Engineering to Sustainability, 2005, :1045-1049
[14]  
*IAQMG, 1999, GOV HONG KONG SPEC A
[15]  
Institute of Environmental Epidemiology, 1996, GUID GOOD IND AIR QU
[16]   Evaluation of indoor air quality using the decibel concept based on carbon dioxide and TVOC [J].
Jokl, MV .
BUILDING AND ENVIRONMENT, 2000, 35 (08) :677-697
[17]  
MCLIUS J, 1984, ACGIH, V10, P3
[18]   Development and application of a protocol for the assessment of indoor air quality [J].
Möhle, G ;
Crump, D ;
Brown, V ;
Hunter, C ;
Squire, R ;
Mann, H ;
Raw, GJ .
INDOOR AND BUILT ENVIRONMENT, 2003, 12 (03) :139-149
[19]  
Mooney Christopher Z., 1997, Monte Carlo simulation
[20]   Evaluation on sampling point densities for assessing indoor air quality [J].
Mui, K. W. ;
Wong, L. T. ;
Ho, W. L. .
BUILDING AND ENVIRONMENT, 2006, 41 (11) :1515-1521