Influence of observers, threshold values, and measurement methods on volumetric analysis of cerebral aneurysms with three-dimensional rotational angiography

被引:0
|
作者
Cho, Won-Sang [1 ]
Shin, Dong Hoon [2 ]
Lee, Joongyub [3 ]
Lee, Seung Jin [1 ]
机构
[1] Kangwon Natl Univ, Sch Med, Kangwon Natl Univ Hosp, Dept Neurosurg, Chuncheon Si, Gangwon Do, South Korea
[2] Kangwon Natl Univ Hosp, Dept Radiol, Chuncheon Si, Gangwon Do, South Korea
[3] Seoul Natl Univ Hosp, Div Clin Epidemiol, Med Res Collaborating Ctr, Biomed Res Inst, Seoul 110744, South Korea
关键词
DIGITAL-SUBTRACTION-ANGIOGRAPHY; BARE PLATINUM COILS; INTRACRANIAL ANEURYSMS; PACKING; APPROXIMATION; TRIAL;
D O I
10.1136/neurintsurg-2014-011444
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Introduction Exact measurements of cerebral aneurysms are important in terms of their treatment. However, there is no definitive way to estimate the exact volume of an aneurysm. Our aim was to compare aneurysm volume measured under different conditions: threshold values, observers, and measurement methods. Methods 40 aneurysms and 7 phantom models were included in the study. Three-dimensional rotational angiography was used, and volumes were compared based on the following factors: two methods (two-dimensional formula calculation and three-dimensional software measurement); three observers; and three threshold values for imaging. In addition, in the phantom models, measured volumes were compared with real volumes. The consistency of the volume measurements under different conditions was assessed using the intraclass correlation coefficient (ICC). Results The consistency of the measured volumes was excellent in both the patient aneurysms (ICC >0.98) and phantom models (ICC >0.95), irrespective of the influencing factors. Median volume differences were small for observers, threshold values, and methods. When the measured and real volumes of the phantom models were compared, the software measurement achieved the highest reproducibility for real volumes compared with the formula calculation (ICC=0.86-0.93 vs 0.71-0.80). Conclusions Measurement of aneurysm volume showed high agreement within each influencing factor, such as methods, observers, and threshold values.
引用
收藏
页码:203 / 207
页数:5
相关论文
共 22 条
  • [1] Three-dimensional rotational angiography in the diagnosis of cerebral aneurysms
    Capello, D
    Mavilio, N
    Allegretti, L
    Rosa, ML
    RIVISTA DI NEURORADIOLOGIA, 2003, 16 : 45 - 50
  • [2] Three-dimensional rotational angiography for craniotomy planning and postintervention evaluation of intracranial aneurysms
    Pedicelli, A.
    Desiderio, F.
    Esposito, G.
    Rollo, M.
    Albanese, A.
    Verdolotti, T.
    D'Argento, F.
    Bonomo, L.
    Maira, G.
    Colosimo, C.
    RADIOLOGIA MEDICA, 2013, 118 (03): : 415 - 430
  • [3] Intra-arterial haemodynamic changes during cerebral three-dimensional rotational angiography
    Waldenberger, Peter
    Chemelli, Andreas
    Mallouhi, Ammar
    EUROPEAN RADIOLOGY, 2009, 19 (02) : 503 - 508
  • [4] Three-dimensional rotational angiography for craniotomy planning and postintervention evaluation of intracranial aneurysms
    Pedicelli, A.
    Desiderio, F.
    Esposito, G.
    Rollo, M.
    Albanese, A.
    Verdolotti, T.
    D'Argento, F.
    Bonomo, L.
    Maira, G.
    Colosimo, C.
    RADIOLOGIA MEDICA, 2013, 118 (03): : 415 - 430
  • [5] Three-dimensional computed tomographic angiography as preoperative examination for cerebral aneurysms treatment
    De Araujo, IS
    ARQUIVOS DE NEURO-PSIQUIATRIA, 1998, 56 (04) : 798 - 802
  • [6] Three-Dimensional Morphometric Analysis of Anterior Cerebral Circulation Aneurysms
    Saal-Zapata, Giancarlo
    Walker, Melanie
    Cervantes-Medina, Rosa
    Rodriguez-Varela, Rodolfo
    INTERNATIONAL JOURNAL OF ANGIOLOGY, 2024, 33 (01) : 22 - 28
  • [7] Three-dimensional computed tomographic angiography in detection of cerebral aneurysms in acute subarachnoid hemorrhage
    Zouaoui, A
    Sahel, M
    Marro, B
    Clemenceau, S
    Dargent, N
    Bitar, A
    Faillot, T
    Capelle, L
    Marsault, M
    NEUROSURGERY, 1997, 41 (01) : 125 - 130
  • [8] Three-dimensional reconstructed images after rotational angiography in the evaluation of intracranial aneurysms: Surgical correlation
    Tanoue, S
    Kiyosue, H
    Kenai, H
    Nakamura, T
    Yamashita, M
    Mori, H
    NEUROSURGERY, 2000, 47 (04) : 866 - 871
  • [9] Low-Dose Three-Dimensional Rotational Angiography for Evaluating Intracranial Aneurysms: Analysis of Image Quality and Radiation Dose
    Ki, Hee Jong
    Kim, Bum-Soo
    Kim, Jun-Ki
    Choi, Jai Ho
    Shin, Yong Sam
    Choi, Yangsean
    Shin, Na-Young
    Jang, Jinhee
    Ahn, Kook-Jin
    KOREAN JOURNAL OF RADIOLOGY, 2022, 23 (02) : 256 - 263
  • [10] 256-row multislice CT angiography in the postoperative evaluation of cerebral aneurysms treated with titanium clips: using three-dimensional rotational angiography as the standard of reference
    Kim, Hye Jeong
    Yoon, Dae Young
    Kim, Eun Soo
    Yun, Eun Joo
    Jeon, Hong Jun
    Lee, Jong Young
    Cho, Byung-Moon
    EUROPEAN RADIOLOGY, 2020, 30 (04) : 2152 - 2160