Corneal hysteresis measured with the Ocular Response Analyzer® in normal and glaucomatous eyes

被引:86
作者
Abitbol, Olivia [1 ,2 ,3 ]
Bouden, Jihene [2 ,3 ]
Doan, Serge [2 ,3 ]
Hoang-Xuan, Thanh [2 ,3 ]
Gatinel, Damien [2 ,3 ]
机构
[1] St Joseph Fdn, Glaucoma Inst, Dept Ophthalmol, F-75674 Paris 14, France
[2] Hop Bichat Claude Bernard, Dept Ophthalmol, F-75877 Paris 18, France
[3] Rothschild Fdn, Dept Ophthalmol, Paris, France
关键词
central corneal thickness; corneal biomechanics; glaucoma; hysteresis; INTRAOCULAR-PRESSURE; BIOMECHANICAL PROPERTIES; ACQUIRED PIT; OPTIC-NERVE; RISK-FACTOR; THICKNESS; HYPERTENSION; DAMAGE;
D O I
10.1111/j.1755-3768.2009.01554.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To identify differences in corneal hysteresis (CH) and central corneal thickness (CCT) between healthy and glaucomatous patients. Methods: Retrospective observational study. One hundred and thirty-three eyes of 75 healthy and 58 glaucomatous patients were included. CH was measured in each patient using Ocular Response Analyzer. CCT was determined by ultrasonic pachymetry. For each patient, one eye was randomly selected. We used a Student t-test to search for significant differences between the different groups (p < 0.05). Results: In healthy and glaucomatous eyes, mean CH values were 10.46 +/- 1.6 and 8.77 +/- 1.4 mm Hg, respectively. Mean CCT values were 560.2 +/- 36.3 and 535.3 +/- 42.7 mu m, respectively. CH and CCT were significantly lower in glaucomatous eyes than in normal eyes, (p < 0.05). Discussion: In our series, CH was lower in glaucomatous than in normal eyes. The relationship between glaucoma, IOP, and ocular structures may not be confined to the consideration of CCT. A low CH value could be responsible for under-estimation of IOP. CH could also be a risk factor for glaucoma, independent of IOP. Further studies are needed to support these hypotheses. Conclusion: In our investigation, CCT and CH were significantly lower in glaucomatous eyes than in healthy eyes.
引用
收藏
页码:116 / 119
页数:4
相关论文
共 23 条
  • [1] Lower corneal hysteresis in glaucoma patients with acquired pit of the optic nerve (APON)
    Bochmann, Frank
    Ang, Ghee S.
    Azuara-Blanco, Augusto
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2008, 246 (05) : 735 - 738
  • [2] Central corneal thickness and corneal hysteresis associated with glaucoma damage
    Congdon, NG
    Broman, AT
    Bandeen-Roche, K
    Grover, D
    Quigley, HA
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (05) : 868 - 875
  • [3] Copt RP, 1999, ARCH OPHTHALMOL-CHIC, V117, P14
  • [4] EHLERS N, 1975, ACTA OPHTHALMOL, V53, P34
  • [5] Central corneal thickness and intraocular pressure in a Mongolian population
    Foster, PJ
    Baasanhu, J
    Alsbirk, PH
    Munkhbayar, D
    Uranchimeg, D
    Johnson, GJ
    [J]. OPHTHALMOLOGY, 1998, 105 (06) : 969 - 973
  • [6] Accuracy of clinical estimates of intraocular pressure in Chinese eyes
    Foster, PJ
    Wong, JS
    Wong, E
    Chen, FG
    Machin, D
    Chew, PTK
    [J]. OPHTHALMOLOGY, 2000, 107 (10) : 1816 - 1821
  • [7] Gordon MO, 2002, ARCH OPHTHALMOL-CHIC, V120, P714
  • [8] Central corneal thickness as a risk factor for advanced glaucoma damage
    Herndon, LW
    Weizer, JS
    Stinnett, SS
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2004, 122 (01) : 17 - 21
  • [9] Central corneal thickness correlated with glaucoma damage and rate of progression
    Jonas, JB
    Stroux, A
    Velten, I
    Juenemann, A
    Martus, P
    Budde, WM
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (04) : 1269 - 1274
  • [10] Corneal hysteresis using the Reichert ocular response analyser: findings pre- and post-LASIK and LASEK
    Kirwan, Caitriona
    O'Keefe, Michael
    [J]. ACTA OPHTHALMOLOGICA, 2008, 86 (02) : 215 - 218