Effect of door opening and defrost cycle on a freezer with phase change panels

被引:109
作者
Gin, B. [1 ]
Farid, M. M. [1 ]
Bansal, P. K. [2 ]
机构
[1] Univ Auckland, Dept Chem & Mat Engn, Auckland 1142, New Zealand
[2] Univ Auckland, Dept Mech Engn, Auckland 1142, New Zealand
关键词
Phase change material; Freezer; Energy consumption; Door opening; Defrost; Power loss; LATENT-HEAT STORAGE; PERFORMANCE; REFRIGERATORS;
D O I
10.1016/j.enconman.2010.06.005
中图分类号
O414.1 [热力学];
学科分类号
摘要
An investigation into the effectiveness of phase change material (PCM) panels placed against the internal walls of a freezer to maintain stable temperatures in the presence of heat loads such as door openings, defrosting, and loss of electrical power was carried out. Temperature response was studied during loss of power, a defrost cycle lasting 30 min, and a door opening scheme of 13 door openings over an 11 h period. This PCM system has significantly decreased the rate of temperature increase inside the freezer during defrosting and power loss. Energy consumption was measured during steady operation, a defrost cycle of 30 min, and a scheme of eight door openings at 40 min intervals. It was found that heat loads caused greater energy consumption, and that the presence of PCM during defrosting and door openings resulted in slightly lower energy consumption compared to without PCM. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2698 / 2706
页数:9
相关论文
共 15 条
[1]  
*AS NZS, 2007, 447412007 ASNZS
[2]   Investigation of the thermal performance of a passive solar test-room with wall latent heat storage [J].
Athienitis, AK ;
Liu, C ;
Hawes, D ;
Banu, D ;
Feldman, D .
BUILDING AND ENVIRONMENT, 1997, 32 (05) :405-410
[3]   Performance enhancement of a household refrigerator by addition of latent heat storage [J].
Azzouz, K. ;
Leducq, D. ;
Gobin, D. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (05) :892-901
[4]   Developing new test procedures for domestic refrigerators: harmonisation issues and future R&D needs - a review [J].
Bansal, PK .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2003, 26 (07) :735-748
[5]  
Bansal PK, 2001, ENERGY EFFICIENCY IN HOUSEHOLD APPLIANCES AND LIGHTING, P404
[6]   TEST STANDARDS FOR HOUSEHOLD REFRIGERATORS AND FREEZERS .1. PRELIMINARY COMPARISONS [J].
BANSAL, PK ;
KRUGER, R .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1995, 18 (01) :4-20
[7]   EXPERIMENTAL-STUDY OF DIRECTIONAL SOLIDIFICATION OF AQUEOUS AMMONIUM-CHLORIDE SOLUTION [J].
CHEN, CF ;
CHEN, F .
JOURNAL OF FLUID MECHANICS, 1991, 227 :567-586
[8]   Underfloor heating with latent heat storage [J].
Farid, M ;
Kong, WJ .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2001, 215 (A5) :601-609
[9]   A review on phase change energy storage: materials and applications [J].
Farid, MM ;
Khudhair, AM ;
Razack, SAK ;
Al-Hallaj, S .
ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (9-10) :1597-1615
[10]   Measurement and prediction of air movement through doorways in refrigerated rooms [J].
Foster, AM ;
Barrett, R ;
James, SJ ;
Swain, MJ .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2002, 25 (08) :1102-1109