PRE-OPERATIVE EVALUATION OF AXILLARY LYMPH NODE STATUS IN PATIENTS WITH SUSPECTED BREAST CANCER USING SHEAR WAVE ELASTOGRAPHY

被引:49
|
作者
Youk, Ji Hyun [1 ]
Son, Eun Ju [1 ]
Kim, Jeong-Ah [1 ]
Gweon, Hye Mi [1 ]
机构
[1] Yonsei Univ, Coll Med, Gangnam Severance Hosp, Dept Radiol, Seoul, South Korea
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2017年 / 43卷 / 08期
关键词
Ultrasonography; Sonoelastography; Shear wave elastography; Axilla; Lymph node; ULTRASOUND ELASTOGRAPHY; SONOGRAPHIC ELASTOGRAPHY; INITIAL-EXPERIENCE; DIAGNOSIS; BENIGN; MASSES; METASTASES; ULTRASONOGRAPHY; LYMPHADENOPATHY; DIFFERENTIATION;
D O I
10.1016/j.ultrasmedbio.2017.03.016
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The aim of this study was to evaluate shear wave elastography (SWE) for pre-operative evaluation of axillary lymph node (LN) status in patients with suspected breast cancer. A total of 130 axillary LNs in 130 patients who underwent SWE before fine-needle aspiration, core biopsy or surgery were analyzed. On gray-scale images, long and short axes, shape (elliptical or round), border (sharp or unsharp) and cortical thickening (concentric, eccentric or no fatty hilum) of LNs were assessed. On SWE, mean, maximum, minimum, standard deviation and the lesion-to-fat ratio (E-ratio) values of elasticity were collected. Gray-scale and SWE features were compared statistically between metastatic and benign LNs using the x(2)-test and independent t-test. Diagnostic performance of each feature was evaluated using the area under the receiver operating characteristic curve (AUC). Logistic regression analysis was used to determine gray-scale or SWE features independently associated with metastatic LNs. Of the 130 LNs, 65 (50%) were metastatic and 65 (50%) were benign after surgery. Metastatic LNs were significantly larger (p - 0.018); had higher elasticity indexes at SWE (p < 0.0001); and had higher proportions of round shape (p = 0.033), unsharp border (p = 0.048) and eccentric cortical thickening or no fatty hilum (p = 0.005) compared with benign LNs. On multivariate analysis, E-ratio was independently associated with metastatic LNs (odds ratio = 3.312, p = 0.008). E-ratio had the highest AUC among gray-scale (0.582-0.719) and SWE (0.900-0.950) variables. SWE had good diagnostic performance in metastatic axillary LNs, and E-ratio was independently associated with metastatic LNs. (E-mail: jhyouk@yuhs.ac) (C) 2017 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1581 / 1586
页数:6
相关论文
共 50 条
  • [41] Second-Look Ultrasound Using Shear-Wave Elastography in MRI-Suspected Locoregional Recurrence of Breast Carcinoma
    Divjak, Eugen
    Ivanac, Gordana
    Radovic, Niko
    Spoljar, Iva Biondic
    Sovic, Slavica
    Bahnik, Valentina
    Brkljacic, Boris
    ULTRASCHALL IN DER MEDIZIN, 2022, 43 (03): : 274 - 279
  • [42] Qualitative Classification of Shear Wave Elastography for Differential Diagnosis Between Benign and Metastatic Axillary Lymph Nodes in Breast Cancer
    Luo, Shuyi
    Yao, Guangyu
    Hong, Zhe
    Zhang, Shiyu
    Wang, Weizhen
    Zhang, Jingwen
    Zhang, Yaru
    Wu, Junkai
    Zhang, Li
    Cheng, Hong
    Hao, Yi
    Li, Yingjia
    FRONTIERS IN ONCOLOGY, 2019, 9
  • [43] Fusion of B-mode and shear wave elastography ultrasound features for automated detection of axillary lymph node metastasis in breast carcinoma
    Pham, The-Hanh
    Faust, Oliver
    Koh, Joel En Wei
    Ciaccio, Edward J.
    Barua, Prabal D.
    Omar, Norlia
    Ng, Wei Lin
    Ab Mumin, Nazimah
    Rahmat, Kartini
    Acharya, U. Rajendra
    EXPERT SYSTEMS, 2022, 39 (05)
  • [44] Axillary lymph node dissection is not obligatory in breast cancer patients with biopsy-proven axillary lymph node metastasis
    Yoo, Tae-Kyung
    Kang, Bong Joo
    Kim, Sung Hun
    Song, Byung Joo
    Ahn, Juneyoung
    Park, Woo-Chan
    Chae, Byung Joo
    BREAST CANCER RESEARCH AND TREATMENT, 2020, 181 (02) : 403 - 409
  • [45] HOW PRE-OPERATIVE SENTINEL LYMPH NODE CONTRAST-ENHANCED ULTRASOUND HELPS INTRA-OPERATIVE SENTINEL LYMPH NODE BIOPSY IN BREAST CANCER: INITIAL EXPERIENCE
    Li, Juan
    Lu, Man
    Cheng, Xueqing
    Hu, Ziyue
    Li, Hui
    Wang, Hao
    Jiang, Jingzhen
    Li, Tingting
    Zhang, Zhenqi
    Zhao, Caihong
    Ma, Yue
    Tan, Bo
    Liu, Jingping
    Yu, Yuan
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (08): : 1865 - 1873
  • [46] Comparison of the diagnostic performance of shear wave elastography with shear wave dispersion for pre-operative staging of hepatic fibrosis in patients with hepatocellular carcinoma
    Wang, Kun
    Yu, Dong
    Li, Gaofeng
    Wen, Li
    Zhang, Shuchen
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 154
  • [47] Axillary Nodal Burden in Breast Cancer Patients With Pre-operative Fine Needle Aspiration-proven Positive Lymph Nodes Compared to Those With Positive Sentinel Nodes
    Cipolla, Calogero
    Valerio, Maria Rosaria
    Grassi, Nello
    Calamia, Sergio
    Latteri, Stefania
    Latteri, Mario
    Graceffa, Giuseppa
    Vieni, Salvatore
    IN VIVO, 2020, 34 (02): : 729 - 734
  • [48] Feasibility of sentinel lymph node biopsy in breast cancer patients clinically suspected of axillary lymph node metastasis on preoperative imaging
    Kwak, Hee Yong
    Chae, Byung Joo
    Bae, Ja Seong
    Kim, Eun Jin
    Chang, Eun Young
    Kim, Sang Hoon
    Jung, Sang Seol
    Song, Byung Joo
    WORLD JOURNAL OF SURGICAL ONCOLOGY, 2013, 11
  • [49] Feasibility of sentinel lymph node biopsy in breast cancer patients clinically suspected of axillary lymph node metastasis on preoperative imaging
    Hee Yong Kwak
    Byung Joo Chae
    Ja Seong Bae
    Eun Jin Kim
    Eun Young Chang
    Sang Hoon Kim
    Sang Seol Jung
    Byung Joo Song
    World Journal of Surgical Oncology, 11
  • [50] Ultrasound elastography as an adjuvant to conventional ultrasound in the preoperative assessment of axillary lymph nodes in suspected breast cancer: A pilot study
    Taylor, K.
    O'Keeffe, S.
    Britton, P. D.
    Wallis, M. G.
    Treece, G. M.
    Housden, J.
    Parashar, D.
    Bond, S.
    Sinnatamby, R.
    CLINICAL RADIOLOGY, 2011, 66 (11) : 1064 - 1071