Experimental investigation of turbulent heat transfer by counter and co-swirling flow in a flat tube fitted with twin twisted tapes

被引:52
|
作者
Abdolbaqi, M. Kh. [1 ]
Azmi, W. H. [1 ,2 ]
Mamat, Rizalman [1 ,2 ]
Mohamed, N. M. Z. N. [1 ,2 ]
Najafi, G. [3 ]
机构
[1] Univ Malaysia Pahang, Fac Mech Engn, Pekan 26600, Pahang, Malaysia
[2] Univ Malaysia Pahang, Automot Engn Ctr, Pekan 26600, Pahang, Malaysia
[3] Tarbiat Modares Univ, Tehran, Iran
关键词
Heat transfer coefficient; Friction factor; Twin twisted tape; Flat tube; PRESSURE-DROP; CIRCULAR TUBE; LAMINAR-FLOW; TRANSFER ENHANCEMENT; TRANSFER COEFFICIENT; THERMAL PERFORMANCE; INSERTS; NANOFLUID; FRICTION; ELEMENTS;
D O I
10.1016/j.icheatmasstransfer.2016.04.021
中图分类号
O414.1 [热力学];
学科分类号
摘要
The use of inserts has gained extensive attention due to their role in improving the efficiency of thermal systems. In this study, an experimental investigation was conducted to explore the effect of twin counter and co-twisted tapes on heat transfer rate (Nu), friction factor (f) and thermal enhancement index (eta). The twin counter twisted tapes (CTT) and twin co-twisted tapes (CoTT) were used as swirl flow generators in a test section. The tests were conducted using the CTT and CoTT with three different twist ratios (H/D) = 5, 10 and 15) for Reynolds numbers range between 7200 and 32,400 under uniform heat flux conditions. The results show that Nusselt number (Nu), friction factor (f) and thermal enhancement index (eta) increase with decreasing twist ratio (H/D) and the CTT is more efficient than the CoTT for heat transfer enhancement. Within the scope of this study, heat transfer rates in the flat tube fitted with the CTT are around 22.5% and 61% higher than those with the CoTT and plain flat tube, respectively. The maximum thermal enhancement index (eta) obtained at the constant flow rate by the CTT with H/D = 5, 10 and 15, are 1.58, 1.44 and 1.15 respectively, while those obtained using the CoTT with the same range of H/D are 1.43, 1.19 and 1.04, respectively. Furthermore, the empirical correlations of the heat transfer (Nu), friction factor (I) and thermal enhancement index (eta) are also reported. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:295 / 302
页数:8
相关论文
共 50 条
  • [21] Mechanics of heat transfer through twisted tape fitted in heat exchanger tube in turbulent regime
    Abhijit Rajan
    Rahul Raj
    Simu Sneha
    Shivesh Kumar
    Laljee Prasad
    International Journal of Advances in Engineering Sciences and Applied Mathematics, 2023, 15 : 95 - 102
  • [22] Effect of non-uniform magnetic field on heat transfer of swirling ferrofluid flow inside tube with twisted tapes
    Mokhtari, Mojtaba
    Hariri, Saman
    Gerdroodbary, M. Barzegar
    Yeganeh, Rezvan
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2017, 117 : 70 - 79
  • [23] NUMERICAL STUDY ON HEAT TRANSFER AND RESISTANCE OF A TUBE FITTED WITH NEW TWISTED TAPES FOR LUBRICATING OIL
    Liu, Xiaoya
    Ding, Ming
    Bian, Haozhi
    Yan, Changqi
    Li, Chun
    PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 8, 2017,
  • [24] LAMINAR HEAT TRANSFER AUGMENTATION THROUGH A SQUARE DUCT AND CIRCULAR TUBE FITTED WITH TWISTED TAPES
    Patil, S. V.
    Babu, P. V. Vijay
    EXPERIMENTAL HEAT TRANSFER, 2014, 27 (02) : 124 - 143
  • [25] Turbulent thermal, fluid flow and thermodynamic characteristics in a plain tube fitted with overlapped multiple twisted tapes
    Hong, Yuxiang
    Du, Juan
    Wang, Shuangfeng
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 115 : 551 - 565
  • [26] Heat transfer and friction factor characteristics in turbulent flow through a tube fitted with perforated twisted tape inserts
    Bhuiya, M. M. K.
    Chowdhury, M. S. U.
    Saha, M.
    Islam, M. T.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2013, 46 : 49 - 57
  • [27] Experimental investigation of heat transfer enhancement of a heat exchanger tube equipped with double-cut twisted tapes
    Nakhchi, M. E.
    Hatami, M.
    Rahmati, M.
    APPLIED THERMAL ENGINEERING, 2020, 180
  • [28] Thermohydraulics of Turbulent Flow Through Heat Exchanger Tubes Fitted with Circular-rings and Twisted Tapes
    Eiamsa-ard, Smith
    Kongkaitpaiboon, Vichan
    Nanan, Kwanchai
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2013, 21 (06) : 585 - 593
  • [29] Investigation of heat transfer performance and flow characteristic in helically coiled-twisted flat tube
    Peng, Xu
    Wang, Dingbiao
    Wang, Guanghui
    Yang, Yushen
    Xiang, Sa
    EXPERIMENTAL HEAT TRANSFER, 2020, 33 (05) : 419 - 439
  • [30] HEAT-TRANSFER TO GAS-LIQUID MIXTURES IN A VERTICAL TUBE FITTED WITH TWISTED-TAPES
    NOORUDDIN, AF
    MURTI, PS
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1973, 16 (08) : 1655 - 1657