Nanostructured electrodes for biocompatible CMOS integrated circuits

被引:10
作者
Graham, Anthony H. D. [1 ]
Bowen, Chris R. [2 ]
Robbins, Jon [3 ]
Lalev, Georgi [4 ]
Marken, Frank [5 ]
Taylor, John [1 ]
机构
[1] Univ Bath, Dept Elect & Elect Engn, Bath BA2 7AY, Avon, England
[2] Univ Bath, Dept Mech Engn, Bath BA2 7AY, Avon, England
[3] Kings Coll London, Receptors & Signalling Wolfson CARD, Higher Educ Acad Teaching Practice, London SE1 1UL, England
[4] Cardiff Univ, Mfg Engn Ctr, Nanomfg Technol Lab, Cardiff CF24 3AA, S Glam, Wales
[5] Univ Bath, Dept Chem, Bath BA2 7AY, Avon, England
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2010年 / 147卷 / 02期
基金
英国工程与自然科学研究理事会;
关键词
Electrode; CMOS; Anodic aluminum oxide (AAO); Biocompatibility; Impedance; Biosensor; POROUS ANODIC ALUMINA; PULSED ELECTRODEPOSITION; NANOWIRE ARRAYS; BARRIER LAYER; CU ALLOY; SILICON; GROWTH; OXIDE; FABRICATION; TEMPLATE;
D O I
10.1016/j.snb.2010.03.030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper reports on the adaptation of standard complementary metal oxide semiconductor (CMOS) integrated circuit (IC) technology for biocompatibility, enabling a low-cost solution for drug discovery pharmacology, neural interface systems, cell-based biosensors and electrophysiology. The basis for the process is the anodisation of IC aluminium electrodes to form nanoporous alumina. The porous alumina was electrochemically thinned to reduce the alumina electrode impedance. For applications where a porous electrode surface is either preferred or acceptable, we demonstrated that porosity can be manipulated at room temperature by modifying the anodising electrolyte to include up to 40% polyethylene glycol and reducing the phosphoric acid concentration from 4% (w/v) to 1%. For applications requiring a planar microelectrode surface, a noble metal was electrodeposited into the pores of the alumina film. Limited success was achieved with a pH 7 platinum and pH 5 gold cyanide bath but good results were demonstrated with a pH 0.5 gold chloride bath which produced planar biocompatible electrodes. A further reduction in impedance was produced by deposition of platinum-black, which may be a necessary additional step for demanding applications such as neuronal recording. During this work a capability for real-time electrochemical impedance spectroscopy (EIS) was developed to study anodisation, barrier oxide thinning, oxide breakdown and electrodeposition processes. To study the pore morphology, focused ion beam (FIB) was employed to produce cross-sectional cuts of the IC features which were inspected by SEM with an 'In-lens' detector. The anodisation process and the optional electrodeposition steps require only simple bench equipment operated at room temperature and is therefore a viable route for manufacturing low-cost biocompatible electrodes from standard CMOS ICs. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:697 / 706
页数:10
相关论文
共 50 条
  • [31] A New Sensor for Temperature Self-Protection of Integrated Circuits in CMOS Technology
    Cartagena, Luis Q.
    Barbin, Silvio E.
    Salcedo, Walter J.
    [J]. 2018 IEEE MTT-S LATIN AMERICA MICROWAVE CONFERENCE (LAMC 2018), 2018,
  • [32] Advanced SiGeBiCMOS and CMOS platforms for optical and millimeter-wave integrated circuits
    Chevalier, P.
    Gloria, D.
    Scheer, P.
    Pruvost, S.
    Gianesello, F.
    Pourchon, F.
    Garcia, P.
    Vildeuil, J. -C.
    Chantre, A.
    Garnier, C.
    Noblanc, O.
    Voinigescu, S. P.
    Dickson, T. O.
    Laskin, E.
    Nicolson, S. T.
    Chalvatzis, T.
    Yau, K. H. K.
    [J]. IEEE COMPOUND SEMICONDUCTOR INTEGRATED CIRCUIT SYMPOSIUM - 2006 IEEE CSIC SYMPOSIUM, TECHNICAL DIGEST 2006, 2006, : 12 - 15
  • [33] New prototype assembly methods for biosensor integrated circuits
    Graham, Anthony H. D.
    Bowen, Chris R.
    Surguy, Susan M.
    Robbins, Jon
    Taylor, John
    [J]. MEDICAL ENGINEERING & PHYSICS, 2011, 33 (08) : 973 - 979
  • [34] Testing of CMOS circuits
    [J]. Veitsman, I.N., 1600,
  • [35] Enabling the Integrated Circuits of the Future
    Fitzgerald, E. A.
    Lee, K. E.
    Yoon, S. F.
    Chua, S. J.
    Tan, C. S.
    Palacios, T.
    Zhou, X.
    Chang, J. S.
    Kohen, D. A.
    Zhang, L.
    Lee, K. H.
    Liu, Z. H.
    Chiah, S. B.
    Ge, T.
    [J]. PROCEEDINGS OF THE 2015 IEEE INTERNATIONAL CONFERENCE ON ELECTRON DEVICES AND SOLID-STATE CIRCUITS (EDSSC), 2015, : 1 - 4
  • [36] Engineering TID modeling for the SEE and performances evaluations of integrated CMOS circuits at cryogenic temperatures
    Artola, L.
    Ducret, S.
    Hubert, G.
    [J]. 2019 19TH EUROPEAN CONFERENCE ON RADIATION AND ITS EFFECTS ON COMPONENTS AND SYSTEMS (RADECS), 2022, : 121 - 125
  • [37] A CMOS Micromachined Capacitive Tactile Sensor With Integrated Readout Circuits and Compensation of Process Variations
    Tsai, Tsung-Heng
    Tsai, Hao-Cheng
    Wu, Tien-Keng
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2014, 8 (05) : 608 - 616
  • [38] Silicon Diode Uncooled FPA With Three-Dimensional Integrated CMOS Readout Circuits
    Xue, Xingjun
    Xiong, Hao
    Song, Zhen
    Du, Yuxin
    Wu, Dong
    Pan, Liyang
    Wang, Zheyao
    [J]. IEEE SENSORS JOURNAL, 2019, 19 (02) : 426 - 434
  • [39] CMOS-based carbon nanotube pass-transistor logic integrated circuits
    Ding, Li
    Zhang, Zhiyong
    Liang, Shibo
    Pei, Tian
    Wang, Sheng
    Li, Yan
    Zhou, Weiwei
    Liu, Jie
    Peng, Lian-Mao
    [J]. NATURE COMMUNICATIONS, 2012, 3
  • [40] A defect-based compact modeling approach for the reliability of CMOS devices and integrated circuits
    Esqueda, Ivan S.
    Barnaby, Hugh J.
    [J]. SOLID-STATE ELECTRONICS, 2014, 91 : 81 - 86